ES2500
Equestrian Scale
Quick User Guide
CODE
MODE
MEANING / POSSIBLE SOLUTION
– – – – – –
Normal Operating Mode
Gross Overload. A weight greater than the rated
capacity has been applied to the scale. Remove the
weight from the platter or try re-calibrating the scale.
Otherwise, check for a bad load cell connection or
possible load cell damage due to overloading.
Normal Operating Mode
Indicates that the battery voltage is too low for nor-
mal operation. Re-charge the battery.
Err 3
All Modes
Non-volatile memory read error. One or more setup
parameters have been lost.
Err 4
All Modes
Non-volatile memory write error. Indicator needs
service.
Err 7
Initialization
No reading from the ADC. Make sure there is a load
cell(s) connected to the indicator at start-up.
Err 9
Normal Operating Mode
Span calibration value has been lost. Re-calibrate
the scale.
F1
In configuration mode
Toggle switch on rear of indicator set to configuration
mode, toggle switch to left to return back to normal
weight mode Or check to see if the toggle switch
loom is still connected to main PCB inside indicator.
Display Error Codes
Electromagnetic Compatibility Statement for North America
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant
to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a residential installation. This equipment generates, uses
and can radiate radio frequency energy and if not installed and used in accordance with the instruction
manual, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or television reception which can be determined
by turning the equipment off and on, the user is encouraged to try to correct the interference by one of
the following measures:
Re-orient or relocate the receiving antenna.
Increase the separation between the equipment and the receiver.
Connect the equipment to an outlet different from that to which the receiver is connected.
Consult the dealer or an experienced radio / TV technician for help.
Salter Brecknell Weighing Products
1000 Armstrong Dr.
Fairmont, MN 56031
Toll free: 800-637-0529
Tel: 507-238-8702 Fax: 507-238-8271
e-mail: sales@salterbrecknell.com
www.salterbrecknell.com
12/04 es2500_g.indd PN 43067-0018 e1