XS4 Controller

Installation guide

UBOX4000

E

Installation guide

Guía de instalación

Guide d'installation

Eng

F

UBOX42Dxx.. series

     Mechanical Installation

Instalación mecánica         Installation  mécanique

Eng

F

E

1

2

3

1/18

READER 1

A
B

TAMPER

IN1

IN2

IN3

IN4

IN5

IN6

READER 2

RL1

RL2

RL3

RL4

C

NC

NO

C

NC

NO

C

NC

NO

C

NC

NO

BUS485

Ethernet

10Base-T
100Base-TX

ON

12V

DC

 Input

+

A

B

-

12V

DC

 Output (1A)

Power Input: 12V

DC

-1A

GND

GND

+

-

+

-

+

-

+

-

+

-

+

-

+

-

A

B

+

-

Model:

 CU42E0

104

(4-1/8")

12

1

(4-3/

4")

43

(1-11/16")

10

(3/8")

44

(1-3/4")

13

1

(5-3/

16

")

Ø

4

(5/3

2")

UBOX42DxxG

UBOX42DxxT

Model:

 CU42xx

UBOX 4000

MODEL: CU42E0

READER 1

A
B

TAMPER

IN1

IN2

IN3

IN4

IN5

IN6

READER 2

RL1

RL2

RL3

RL4

C

NC

NO

C

NC

NO

C

NC

NO

C

NC

NO

BUS485

Ethernet
10Base-T

100Base-TX

ON

12V

DC

 Input

+

A

B

-

12V

DC

 Output (1A)

Power Input: 12V

DC

-1A

GND

GND

+
-
+
-
+
-
+
-
+
-
+
-

+

-

A

B

+

-

+

WRD..

WRDxA..

WRDxE..
WRDxS..

WRDxP.. WRDxM..

Model:

 CU42E0

Model:

 CU42xx

UBOX 4000

MODEL: CU42E0

UBOX4000

Model: CU42E0

Model:

 CU42E0

Model:

 CU42xx

UBOX 4000

MODEL: CU42E0

Model:

 CU42E0

Model:

 CU42xx

UBOX 4000

MODEL: CU42E0

UBOX4000

 

*

TAMPER

Note: Follow the same connection model, using the CU tamper input, when using a third party electric box equipped with a
tamper opening detection.

Connect!

Summary of Contents for UBOX4000

Page 1: ...VDC Input A B 12VDC Output 1A Power Input 12V DC 1A GND GND A B Model CU42E0 104 4 1 8 121 4 3 4 43 1 11 16 10 3 8 44 1 3 4 131 5 3 16 4 5 32 UBOX42DxxG UBOX42DxxT Model CU42xx UBOX 4000 MODEL CU42E0...

Page 2: ...e a la entrada de alimentaci n protegida por un fusible de 1 A BUS485 Entradas el instalador ha de identificar el cable para el puente dependiendo de la configuraci n de la entrada Conexi n para el PP...

Page 3: ...el Software 1k recomendado 1k5 2k2 3k3 4k7 6k8 10k Connexion d entr e Connexion d entr e supervis e CUADAPT ou lecteur tiers IN3 IN4 IN5 IN6 Sortie D0 Sortie D1 Sortie D0 Sortie D1 Sortie Clock Sortie...

Page 4: ...e La CU elle seule consome 400mA D pendant de l installataion l installateur doit calculer l alimentation n cessaire Note 2 M me tension que l entr e Note 3 R sistance de pull up 1K Note 4 Consultez l...

Page 5: ...EADER 2 RL1 RL2 RL3 RL4 C NC NO C NC NO C NC NO C NC NO BUS485 Ethernet 10Base T 100Base TX ON 12VDC Input A B 12VDC Output 1A Power Input 12VDC 1A GND GND A B Model CU42E0 Model CU42xx UBOX 4000 MODE...

Page 6: ...er guide assign the IP address to the UBOX4000 3 Adress the CU42E0 3 1 Press the CLR BUTTON CU42E0 to detect the readers Check that the reader s LEDs blink and the BUS485 LEDs are switched ON 3 2 The...

Page 7: ...manual de usuario de usuario de SALTRO ProAccess SPACE 3 Direccionar la UBOX4000 3 1 Pulsaci n corta del CLR para detectar los lectores Comprobar que los LEDs de los lectores y el BUS485 est n encendi...

Page 8: ...Adresser la UBOX4000 3 1 Appuyer sur la touche CLR pour d tecter les lecteurs V rifier que les voyants des lecteurs clignotent et que les voyants du BUS485 sont allum s 3 2 Le UBOX4000 est un appareil...

Page 9: ...o no est correctamente alimentado comprobar la fuente de alimentaci n NARANJA INTERMITENTE modo direccionamiento OFF sin alimentaci n BUS485 ON UBOX4000 Por definir OFF UBOX4000 Por definir TAMPER ON...

Page 10: ...C NC NO C NC NO BUS485 Ethernet 10Base T 100Base TX ON 12VDC Input A B 12VDC Output 1A Power Input 12V DC 1A GND GND A B Model CU42E0 104 4 1 8 121 4 3 4 43 1 11 16 10 3 8 44 1 3 4 131 5 3 16 4 32 Mo...

Page 11: ...er input poort beschermd door een 1A zekering BUS485 Ingangen Installateur moet vaststellen welke kabel nodig is afhankelijk van de input configuratie Indien geen deursensoren of sabotagecon tact gebr...

Page 12: ...ng Data Ausgang TX Ausgang TX Ausgang Wiegand Omron RS232 Die Widerst ndswert k nnen via Software definiert werden 1k5 2k2 3k3 4k7 6k8 10k Ingangen Ingangen onder toezicht CUADAP en lezers van derden...

Page 13: ...Schwarz Zwart Svart 2 1 READER_2 READER_1 READER_2 READER_1 Gleiches Paar Hetzelfde paar Samma par B A Mindestabstand zwischen Lesern 20in 50 cm Minimale afstand tussen de lezers 20in 50 cm Minsta avs...

Page 14: ...gebruik wordt gemaakt van de 12 V uitgang De controller alleen verbruikt 400mA Afhankelijk van de aangesloten componenten moet de installateur een geschikte voeding berekenen en plaatsen Opm 2 Evenve...

Page 15: ...aster einmal kurz wenn der Sabotagekontakt offen ist Die LED s m ssen einmal kurz aufleuchten 3 2 CU42E0 ist DHCP Vorbereitet In Werksauslieferung ist der DHCP Modus aktiviert Wenn der Kunde keinen DH...

Page 16: ...tellingen en ken het IP adres toe aan de CU42E0 in de software 3 Adresseer de CU42E0 3 1 Klik de CLR knop kort in om de aangesloten lezers te detecteren controleer of de oranje led op de lezers geknip...

Page 17: ...er St ll in dip switcharna f r alla CU4200 och tilldela IP adress till CU42E0 3 Adressera CU42E0 3 1 Tryck p CLR knappen CU42E0 f r att detektera l sarna och den anslutna CU4200 Kontrollera att l sarn...

Page 18: ...De controller is juist gevoed KNIPPEREND ROOD De controller is niet juist gevoed controleer de voeding KNIPPEREND ORANJE adressering modus UIT Geen voeding BUS485 AAN op UBOX4000 Worden gedefinieerd U...

Reviews: