MANUALE DI ISTRUZIONE E INSTALLAZIONE

INSTRUCTION AND INSTALLATION MANUAL

Visual and acoustic alarm indicator with siren shut-off button and buffer battery

Segnalatore  di  allarme  visivo  e  acustico  con  pulsante  tacitazione  sirena  e  batteria 
tampone

TOP ALARM

SS101.xx

rev.4 12/12/2019

ITA/

ENG

customer.service@salupoquadri.com

CUSTOMER  SERVICE

  ( )

+39 0 941.1820216

Summary of Contents for SS101 Series

Page 1: ...l and acoustic alarm indicator with siren shut off button and buffer battery Segnalatore di allarme visivo e acustico con pulsante tacitazione sirena e batteria tampone TOP ALARM SS101 xx rev 4 12 12 2019 ITA ENG customer service salupoquadri com CUSTOMER SERVICE 39 0 941 1820216 ...

Page 2: ...lazione 2 Avvertenze 3 Caratteristiche generali 4 Caratteristiche elettriche e meccaniche 5 Impiego e funzioni del quadro 6 Schema di collegamento SS101 xx 7 Smaltimento di vecchi apparecchi elettrici ed elettronici 8 Dichiarazione di conformità ...

Page 3: ...fettuare i collegamenti elettrici rispettando gli schemi di collegamento Le operazioni di regolazione all interno del quadro devono essere svolte da personale qualificato 1 ISTRUZIONI GENERALI PER L INSTALLAZIONE 2 AVVERTENZE Rischio di scosse elettriche se non si osserva quanto prescritto SCOSSE ELETTRICHE PERICOLO Rischio di lesioni personali e materiali se non si osserva quanto prescritto AVVER...

Page 4: ...DRO A tale ingresso è possibile collegare una qualsiasi sorgente a contatto pulito galleggiante pressostato etc Il TOP ALARM è un dispositivo che serve a segnalare un allarme che viene generato quando l ingresso in morsettiera si chiude Il modello serie SS101 01 è dotato anche di batteria tampone che serve a segnalare gli allarmi anche in assenza di rete Per mezzo di uno jumper presente nella sche...

Page 5: ...ITALIANO 3 5 6 SCHEMA DI COLLEGAMENTO 8 9 BATTERIA LEGENDA 5 6 7 USCITA RELE ALLARME 3 4 INGRESSO ALLARME 1 2 ALIMENTAZIONE BATTERIA RITARDO ALLARME PULSANTE TACITAZIONE LAMPEGGIANTE ...

Page 6: ...6 INDEX ...

Page 7: ...rams When fixing the cables in the terminal board use tools of correct size to avoid damaging the metal feed clamps and their sockets 1 GENERAL INSTRUCTIONS FOR INSTALLING 2 WARNINGS Risk of electric shocks if not complied with the requirements ELECTRIC SHOCKS Risk of personal injury and property if not complied with the requirements DANGER WARNING Before installing and using the product read this...

Page 8: ...u can connect any source with a clean contact to this input float switch pressure switch etc The TOPALARM is a device used to signal an alarm that is generated when the input on the terminal board closes Through a jumper on the board it is possible to activate the function that generates the alarm in the absence of supply mains In the presence of an alarm the device enables a clean contact relay o...

Page 9: ...ENGLISH 6 WIRING DIAGRAM 9 ...

Page 10: ...Salupo Ivan SALUPO S r l Technical Dep Manager 8 DICHIARAZIONE DI CONFORMITA 7 SMALTIMENTODIVECCHI APPARECCHI ELETTRICIED ELETTRONICI Responsabile Ufficio Tecnico SALUPO S r l Salupo Ivan Il costruttore Salupo S r l 98070 Torrenova ME Dichiara che C da Pietra di Roma Via Vicolo VI n 2 gli indicatori TOPALARM sono conformi ai requisiti di protezione in materia di sicurezza bassa tensione e di compa...

Page 11: ...________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________...

Page 12: ...C da Pietra di Roma Via Vicolo VI n 2 98070 Torrenova ME ITALY Tel 39 0941 950216 Fax 39 0941 958777 www salupoquadri com info salupoquadri com e mail ...