background image

L

L

L

COM

RT310T

X

Thermosta

t

RT310T

X

Thermosta

t

NO

N

N

N

L

L

L, N

M

N

N

M

COM

NO

NC

Kocioł

/ sterownik kotła

Połączenie bezprzewodowe

Napięcie zasilania 230 V AC

Siłownik zaworu

Pompa

Bezpiecznik

Przekaźnik beznapięciowy NO

NO

CO

M

NC NO

CO

M

M

OR

MAX

3 (1) A

OR

RXR

T510

Rec

eiv

er

RXR

T510

Rec

eiv

er

A

230 V

A

230 V

AC 230 V

MAX

16 (5) A

RT310

Thermosta

t

RT310

Thermosta

t

Introduction

RT310 / RT310TX / RT310RF is a digital room thermosat used to control room temperature. Device 

launching heating system by shorting terminal blocks, simultaneously informing the action and 

showing this information on the LCD display. Before use please read this manual carefully. Use only 

AA 1.5 V alkaline batteries in the thermostat. Place the batteries into the battery slot located under the 

cover. Do not use rechargeable batteries.

Product compliance

This product complies with the essential requirements and other relevant provisions of the following EU Directives: 

EMC 2014/30/EU, LVD 2014/35/EU, RED 2014/53/EU and RoHS 2011/65/EU. Full text of the EU Declaration of 

Conformity is available on www.saluslegal.com

        

 Safety Information

Use in accordance to national and EU regulations. Use the device as intended, keeping it in dry condition. 

Product for indoor use only. Installation must be carried out by a qualified person in accordance to 

national and EU regulations.

Technical specification

LCD Icon description

Button functions

RT310 Terminals description

RXRT510 Receiver terminals description

RT310 Wiring diagram

RT310RF Wiring diagram

RT310

RT310TX

Thermostat supply

2 x AA alkaline batteries

2 x AA alkaline batteries

Receiver supply

-

230 V AC

Thermostat rating max

3 (1) A

-

Receiver rating max

-

16 (5) A

Outputs

Voltage free   
NO / COM /NC terminals

Voltage free  
NO / COM terminals

Temperature range

5 - 35°C

5 - 35°C

Terminal

Description

1 - COM

Common Terminal

2 - NC

Switched Live OFF

3 - NO

Switched Live ON

Terminal

Description

NO

Switch Terminal

COM

Common Switch Terminal

L, N

Supply (230 V AC)

RT310 / RT310TX Thermostat

RXRT510 Receiver

1

5

6

7

8

3

2

4

1. 

Turn on the LCD backlight

2. 

Turn On/Off the Frost Mode

3. 

Increase button

4. 

Decrease button

1. 

Heating Mode ON

2. 

Frost Protection Mode ON

3. 

RF signal indicator (only in RT310RF)

4. 

Low battery status

5. 

Temperature unit

6. 

Room / setpoint temperature

5. 

When in Manual Mode,  

 

ON will turn the boiler on.

6. 

When in Manual Mode,  

 

OFF will turn the boiler off.

7. 

Receiver operates in automatic mode   

 

according to the thermostat

8. 

Receiver output is controlled  

 

by the On/Off slide switch.

1

5
6

3

2

4

NO  COM    L      N

DIP Switch Settings

L

L

L

COM

RT310T

X

Thermosta

t

RT310T

X

Thermosta

t

NO

N

N

N

L

L

L, N

M

N

N

M

COM

NO

NC

Kocioł

/ sterownik kotła

Połączenie bezprzewodowe

Napięcie zasilania 230 V AC

Siłownik zaworu

Pompa

Bezpiecznik

Przekaźnik beznapięciowy NO

NO

CO

M

NC NO

CO

M

M

OR

MAX

3 (1) A

OR

RXR

T510

Rec

eiv

er

RXR

T510

Rec

eiv

er

A

230 V

A

230 V

AC 230 V

MAX

16 (5) A

RT310

Thermosta

t

RT310

Thermosta

t

L

L

L

COM

RT310T

X

Thermosta

t

RT310T

X

Thermosta

t

NO

N

N

N

L

L

L, N

M

N

N

M

COM

NO

NC

Kocioł

/ sterownik kotła

Połączenie bezprzewodowe

Napięcie zasilania 230 V AC

Siłownik zaworu

Pompa

Bezpiecznik

Przekaźnik beznapięciowy NO

NO

CO

M

NC NO

CO

M

M

OR

MAX

3 (1) A

OR

RXR

T510

Rec

eiv

er

RXR

T510

Rec

eiv

er

A

230 V

A

230 V

AC 230 V

MAX

16 (5) A

RT310

Thermosta

t

RT310

Thermosta

t

L

L

L

COM

RT310T

X

Thermosta

t

RT310T

X

Thermosta

t

NO

N

N

N

L

L

L, N

M

N

N

M

COM

NO

NC

Kocioł

/ sterownik kotła

Połączenie bezprzewodowe

Napięcie zasilania 230 V AC

Siłownik zaworu

Pompa

Bezpiecznik

Przekaźnik beznapięciowy NO

NO

CO

M

NC NO

CO

M

M

OR

MAX

3 (1) A

OR

RXR

T510

Rec

eiv

er

RXR

T510

Rec

eiv

er

A

230 V

A

230 V

AC 230 V

MAX

16 (5) A

RT310

Thermosta

t

RT310

Thermosta

t

Note: 

If you are using the RT310RF pack, the pairing between the thermostat and the receiver  

is already done. 

RT310, RT310TX, RT310RF

1

6CPH

TPI

9CPH

Span

±0.25°C

2

ON ON

The DIP Switches can be found on the rear of your thermostat.

Control feature

TPI

Span

Operation

When TPI is selected on DIP 

switch № 2, the DIP switch № 

1 is functional. You can choose 

the Cycles Per Hour between 

a lower comfort level (6CPH) 

and a higher comfort level 

(9CPH).

When Span is selected 

on DIP switch № 2, 

the DIP switch № 1 is 

not functional.  The 

temperature accuracy of 

your thermostat is set to 

± 0.25 °C.

868.0-868.6MHz; <13dBm

Quick Guide

Summary of Contents for RT310

Page 1: ...RT310 RT310TX RT310RF Quick Guide ...

Page 2: ...rovisionsofthefollowingEUDirectives EMC 2014 30 EU LVD 2014 35 EU RED 2014 53 EU and RoHS 2011 65 EU Full text of the EU Declaration of Conformityisavailableonwww saluslegal com Safety Information UseinaccordancetonationalandEUregulations Usethedeviceasintended keepingitindrycondition Product for indoor use only Installation must be carried out by a qualified person in accordance to national and E...

Page 3: ...0 Receiver 1 5 6 7 8 3 2 4 1 TurnontheLCDbacklight 2 TurnOn OfftheFrostMode 3 Increasebutton 4 Decreasebutton 1 HeatingModeON 2 FrostProtectionModeON 3 RFsignalindicator onlyinRT310RF 4 Lowbatterystatus 5 Temperatureunit 6 Room setpointtemperature 5 WheninManualMode ONwillturntheboileron 6 WheninManualMode OFFwillturntheboileroff 7 Receiveroperatesinautomaticmode accordingtothethermostat 8 Receive...

Page 4: ...T310 Thermostat RT310 Thermostat COM RT310TX Thermostat L L L N M N N NO OR RXRT510 Receiver AC 230 V MAX 16 5 A Note If you are using the RT310RF pack the pairing between the thermostat and the receiver isalreadydone 1 6CPH TPI 9CPH Span 0 25 C 2 ON ON TheDIPSwitchescanbefoundontherearofyourthermostat Control feature TPI Span Operation When TPI is selected on DIP switch 2 the DIP switch 1 is func...

Page 5: ...ss buttontoturn On Offfrostprotection PressanybuttontostoptheSleepMode Actualroomtemperature 3sec 3sec The Frostpoint temperature can be reviewed by pressing the UP button once but can only be changedinInstallerMode WhenSleepModeisactiveallthethermostatfunctionswillbepaused Press or tosetthetemperature ...

Page 6: ...evicesaresuccessfullypaired LEDonthereceiverwillgosolidred PressandholdTEST PAIRINGbutton for3secondstoendthepairing process 3sec 3sec 1sec 1sec If you bought the RT310TX and RXRT510 separately or if you want to re pair thermostat with the receiver make sure that the device is disconnected from the power supply and the switches on the receiver have been set to AUTO and ON Then connect the receiver...

Page 7: ...0 C 5 0 C TEST PAIRING Issue Date June 2019 V020 SALUS Controls plc SALUS House Dodworth Business Park South Whinby Road Dodworth Barnsley S75 3SP UK T 44 0 1226 323961 E sales salus tech com E techsupport salus tech com SALUS Controls is a member of the Computime Group Maintaining a policy of continuous product development SALUS Controls plc reserve the right to change specification design and ma...

Reviews: