background image

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Ex

Cam

®

 miniZoom

 

 
 
 
 

User manual 

 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

Summary of Contents for ExCam miniZoom

Page 1: ...ExCam miniZoom User manual...

Page 2: ...Electrical connection 10 5 2 1 Potential equalization 11 5 2 2 Termination of the connection cable pigtail 11 5 2 3 Power supply protection 13 5 2 4 Power supply protection of the camera s power circu...

Page 3: ...ntrol Panel 16 Figure 5 8 Control and visualization via a video server 16 Figure 5 9 ExCam miniZoom lens and sensor board 17 Figure 9 1 T03 VA K1 20 Figure 9 2 T03 VA K2 20 Revision history Product Ex...

Page 4: ...User Manual Datasheet ExCam niteZoom User Manual Datasheet ExCam vario User Manual Datasheet ExCam IP User Manual Datasheet ExCam HD User Manual Datasheet T08 ExCam Series ATEX IECEx Mining EX Install...

Page 5: ...ence power 24 V DC Power input 67 mA to 208 mA Maximum power input 2 5 W without heating Heating optional Supply voltage 12 V DC to 24 V DC Reference power 24 V DC Power input ca 1000 mA Maximum power...

Page 6: ...in and cable gland 79 x 79 x 128 mm K1 flange with pin and cable gland 79 x 96 x 128 mm K2 flange without pin and cable gland 79 x 79 x 141 mm K2 flange with pin and cable gland 79 x 96 x 141 mm Fitti...

Page 7: ...4 6 tele Aperture F1 8 to F2 9 1 Minimal illumination 1 5 lux Recommended illumination 100 to 100 000 lux Minimal object distance 10 mm wide 1000 mm tele 2 8 Electronical functions Electronical shutt...

Page 8: ...05 K L T03 VA C 005 P N T03 VA C 005 P L 1 VA Execution in stainless steel 2 B Explosion group IIB standard all gases except hydrogen acetylene carbon disulphide C E Explosion group IIC all gases 3 Le...

Page 9: ...ation Install the ExCam miniZoom at the desired location Mounting options accessories as well as safety guidelines are described in the ATEX installation manual of the ExCam Series Attention Please ob...

Page 10: ...cident prevention e g DIN EN 60079 14 as well as the safety guidelines described in this user manual and the ATEX installa tion manual The ExCam miniZoom is delivered with an electrical connection cab...

Page 11: ...t the place indicated in above figure The profile of the potential equalization has to reflect the national grounding instructions min 4mm2 Connection table Potential Color IEC 60757 Profile Comments...

Page 12: ...Doc ID 131106 PT03BA SS ExCam miniZoom_en_rev 01 Seite 12 von 24 Figure 5 3 ExCam miniZoom T03 VA B XXX K L Figure 5 4 ExCam miniZoom T03 VA B XXX P N Figure 5 5 ExCam miniZoom T03 VA B XXX P L...

Page 13: ...power supply The cable length The national regulations The following safety recommendations may serve as a basis Supplied power Length system cable Recommended protection Comments 12 VDC 200 m mT500mA...

Page 14: ...signal of the ExCam miniZoom is either provid ed with wire end K option or with a BNC connector P option The CVBS signal is only to be connected with the monitor the video matrix or the video server...

Page 15: ...and optimization of the camera picture such as angle of view zoom focus back light compensation or IR cut filter are exclusively carried out electronically via the camera s control interface Mechanic...

Page 16: ...Doc ID 131106 PT03BA SS ExCam miniZoom_en_rev 01 Seite 16 von 24 Figure 5 7 FCB Control Panel Figure 5 8 Control and visualization via a video server...

Page 17: ...1 8 s Focus speed W N 0 5s Minimal illumination 1 5 lux Shutter time 1 1 s bis 1 10000 s 16steps MOD Min Object Distance 0 01 m wide end to 1 m tele end Information If not determined differently the d...

Page 18: ...DIN EN 60079 10 it might be necessary to obtain a work permit clearance When adjusting the camera settings potentially explosive atmosphere must be avoided by any means 5 3 2 Opening the pressure res...

Page 19: ...ntenance measures are necessary they have to be initiated and or executed 7 Repairs and Maintenance Repairs must only be carried out with original parts of SAMCON Prozessleittechnik GmbH Damaged press...

Page 20: ...Doc ID 131106 PT03BA SS ExCam miniZoom_en_rev 01 Seite 20 von 24 9 Drawings Figure 9 1 T03 VA K1 Figure 9 2 T03 VA K2...

Page 21: ...Doc ID 131106 PT03BA SS ExCam miniZoom_en_rev 01 Seite 21 von 24 10 Notes...

Page 22: ...Doc ID 131106 PT03BA SS ExCam miniZoom_en_rev 01 Seite 22 von 24...

Page 23: ...Doc ID 131106 PT03BA SS ExCam miniZoom_en_rev 01 Seite 23 von 24...

Page 24: ...Doc ID 131106 PT03BA SS ExCam miniZoom_en_rev 01 Seite 24 von 24 Schillerstrasse 17 35102 Lohra Altenvers www samcon eu info samcon eu fon 49 6426 9231 0 fax 31...

Reviews: