background image

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Ex

Cam

®

 

XI410

 

 
 
 
 
 

User Manual 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

Summary of Contents for ExCam XI410

Page 1: ...ExCam XI410 User Manual ...

Page 2: ... 13 5 2 Variants of cable termination 14 5 3 Connection work at the device terminal box 14 5 4 Plug assignment RJ45 17 5 4 1 Appropriate cables cable entries 19 5 4 2 Fusing 19 5 4 3 Tests prior to switching on voltage 19 6 Network access and visualization 20 6 1 Minimum system requirements 20 6 2 Set up installation first use 20 6 3 Allocating IP adress 20 7 Visualization Analysis Software PIX Co...

Page 3: ...ire assignment of terminal box ExTB 3 SKDP03 T 15 Figure 5 6 Wired terminal box ExTB 3 16 Figure 5 7 ExTB 3 Safe area 17 Figure 5 8 Plug assignment RJ45 17 Figure 5 9 Plug assignment RJ45 18 Figure 7 1 Motorized focus settings in PIX Connect Software 24 Figure 7 2 Adjust temperature range 24 Figure 7 3 User interface 25 History of revisions Product ExCam XI410 Title User Manual for ExCam XI410 Doc...

Page 4: ...gulations ATEX as well as international ones IECEx The explosion protected housing is ap proved for the ATEX group II for zones 1 2 21 and 22 including the explosion groups IIC IIIC For more information please visit our website at www samcon eu en 2 Technical data 2 1 Explosion protection Identification marks acc to Directive 2014 34 EU II 2G zone 1 and 2 II 2D zone 21 and 22 Explosion protection ...

Page 5: ...ction Type 08 3 VA0 4 K1 GER T07 ex d housing stainless steel 1 4404 with small diameter ØVA0 48mm VA0 4 K1 GER T07 VA0 4 housing with maximum body length L R 171 2mm VA0 4 K1 GER K1 cable gland flange VA0 4 K1 GER Germanium sight glass suitable for thermographic applications MIR FIR 4 N N Normal ambient temperature range Tamb 10 C N N No high temperature battery installed Tamb 50 C 5 005 N Length...

Page 6: ... resistance shielded Quick link https www samcon eu fileadmin documents en 60 Assembling 26mounting SKDP03 T_Datasheet pdf Figure 2 3 Sectional view of SKDP03 T 2 5 Optical specifications A selection of lenses offers the possibility to precisely measure objects in different dis tances we offer lenses for close standard and large distances Please note that the ExCam XI410 has a fixed optic A change...

Page 7: ...100 3 200 5 300 15 900 52 900 VFOV 0 036 0 068 0 100 0 160 0 320 0 640 1 300 1 900 3 200 9 500 31 700 DFOV 0 069 0 131 0 190 0 320 0 620 1 240 2 500 3 700 6 200 18 500 61 600 Size of single pixel mm IFOV 2 000 0 300 0 400 0 700 1 400 2 800 5 500 8 300 13 800 41 300 137 700 Enlargement of total measuring field at object level m Distance to measurement object m 80 optic 0 05 0 1 0 2 0 3 0 5 1 2 4 6 ...

Page 8: ...umentation video technical data of optris https www optris com xi 410 2 7 Other technical data Table 2 3 Other technical data Camera Terminal box Permissible ambient temperature 10 C 50 C 60 C 55 C Protection class as per EN 60529 IEC 529 IP66 68 Test conditions 0 5h 8m water column 5 C IP66 Housing material Stainless steel mat no 1 4404 Polyester resin Weight About 0 93 kg 1 kg Dimensions D48mm x...

Page 9: ...ny alterations of the camera The camera must be operated in a proper and sound condition and only in the way intended Attention Repairs may only be carried out by using original parts from the man ufacturer Repairs which affect the explosion protection may only be carried out in accordance with the nationally applied regulations and exclusively by the manufacturer Attention The alignment of the ca...

Page 10: ...the warnings given on the nameplate WARNING DO NOT OPEN IN HAZARD AREAS Using the camera in explosion protected areas with regard to tempera ture and dust layers is defined in the respective national regulations When installing the ExCam adhere to the requirements of the EN IEC 60079 14 ...

Page 11: ... atmosphere To ensure the best image quality delivered by the network camera plan the installation site carefully consider object distance or size angle and minimum object distance to the focus Use appropriate tools and aids When working ensure a safe stand Make sure that any static charge is avoided Attention Please observe the national security installation and accident preven tion regulations e...

Page 12: ...on walls Material stainless steel 1 4404 Weight 0 68 kg Dimensions 80 x 100 x 205 mm Pole adapter PMB POLE MOUNT EXCAM VA1 x Pole apter for VA wall mount Material stainless steel 1 4404 Suitable for pole diameters between 50 and 105 mm Load bearing capacity 45 kg Dimensions 120x180x130 at masts of Ø 60 mm Hinge attachment SCH Hinge attachment SCH VAx x Hinge attachment for easy mounting on round s...

Page 13: ...from the camera to the next active network interface is 100 m and can be specified by the client The user is NOT authorised to carry out any electrical connection work inside the pressure resistant enclosure T08 5 1 Potential equalization Figure 5 1 ExCam XI410 Potential equalization Potential equalization grounding of the camera housing is absolutely necessary in order to avoid static charges and...

Page 14: ...08 VA0 4 K1 GER N N xxx N T 5 3 Connection work at the device terminal box Attention Never open the Ex e terminal box under voltage Attention Adhere to the international installation regulations for connection chambers with increased safety Ex e Attention Adhere to attached separate User Manual for the Ex e terminal box Video Tutorial Observe our video tutorial SAMCON 01 Wiring the cable SKDP03 T ...

Page 15: ...minal ExTB 3 Cross sectional surface Comment SHIELD PE 1 5 mm2 Shield Tx WH OG 1 0 26 mm2 Solid conductor Tx OG 2 0 26 mm2 Solid conductor Rx WH GN 3 0 26 mm2 Solid conductor Rx GN 4 0 26 mm2 Solid conductor GND ISO WH BU 5 0 26 mm2 Solid conductor AO RS485 B BU 6 0 26 mm2 Solid conductor AI DI RS485 A BN 7 0 26 mm2 Solid conductor n c WH BN 8 0 26 mm2 Solid conductor n c PE VCC BK 9 1 5 mm2 24VDC...

Page 16: ...that the cable shield is grounded on side of the terminal block The maximum cable length is 100 m Attention Finally check your network installation Attention Cables and wires must comply with the requirements of the IEC 60079 0 1 7 14 Attention The supply line must have a sufficient cross section The cable pro tection must comply with national and international regulations ...

Page 17: ...om ExTB 3 to safe area Figure 5 7 ExTB 3 Safe area 5 4 Plug assignment RJ45 Figure 5 8 Plug assignment RJ45 If the cable termination uses a plug the latter should be plugged into the RJ45 PoE slot of the network device PSE Prior to connecting it to the camera the network device PIF 24 VDC IO ...

Page 18: ...J45 plugs Check the cable shielding cross section and the outside diameter Attention It is imperative to ensure a correct routing of the individual wires ac cording to the EIA TIA 568B Detailed instructions on how to connect an RJ45 plug are available in our video tutorial SAMCON 03 Mounting and installing the RJ45 jack to SAMCON cables https go samcon eu v03 Figure 5 9 Plug assignment RJ45 ...

Page 19: ...ease visit our website 5 4 2 Fusing The power supply fusing depends on the cable cross section and length 300 mA mT fuse is recommended Attention Please pay attention to the national and international regulations regarding selectivity and line protection 5 4 3 Tests prior to switching on voltage Attention Prior to starting the device perform all tests as indicated by the na tional regulations Furt...

Page 20: ...ssary The software starts automatically in the installed language 1 Connect the supplied USB stick to your PC 2 Start the Setup exe Follow the instructions of the wizard until the installation is fin ished After installation you will find the software on your desktop as a program icon and in the start menu Start Programs Optris GmbH PIX Connect 3 Select the desired language in the menu Tools Langu...

Page 21: ...al activate the check box Use the following IP address Now enter a user defined IP address for your PC 192 168 0 100 This must be iden tical to the address set in the PIX Connect software 2 Then close the window with OK The network settings on the PC are complete Now press Properties Now select Internet Protocol Version 4 TCP IPv4 in the properties window and then go to Properties again ...

Page 22: ... Start the PIX Connect software and activate the Ethernet func tion To do this go to Devices and Enable Ethernet in the menu 3 Make sure that all three networks Domain Private Public are allowed in the Windows Firewall win dow to ensure a connection to the device 4 ...

Page 23: ...0Mbits s approx 17 devices XI80 Switch with 1000Mbits s approx 170 devices XI80 In addition to the data rate you should also pay attention to the PC performance A separate instance is required for each device used The device is now ready for the Ethernet connection and is listed in the menu Devices The camera is iden tified by a network symbol and the network address and port number Select the dev...

Page 24: ...ttps www optris com xi 410 The radiometric processing of the image data enables subsequent detailed image analy sis with the convenient PIX Connect software 7 2 Focusing the thermal image To make sure that the focus of thermal channel is adjusted correctly the motorized focus can be adjusted in the PIX Connect software Menu View Windows Dis tance or over the icon Adjustment to the left near adjust...

Page 25: ...eded and to BLUE when it falls below 4 Temperature of measure area Analyses the temperature according to the selected shape of the field e g the mean value of the rectangle This value is also shown in the live image top right and in the digital display 5 Reference bar Shows a color scale with the corresponding temperature values 6 Temperature time diagram Shows the temperature curve over time for ...

Page 26: ...The required maintenance intervals are specific to the individual devices The operating company has to determine these intervals depending on the application parameters The maintenance tasks especially include examination of parts on which the ignition protec tion depends e g proper condition of the casing seals and cable entry points If maintenance measures are necessary they have to be initiated...

Page 27: ...gs 3D models All drawings 3D models certificates and other information are available in the download area of the product page on our website https www samcon eu en products network excam xi410 If you wish additional technical information please contact us at support samcon eu ...

Page 28: ...Schillerstrasse 17 35102 Lohra Altenvers Germany www samcon eu info samcon eu Phone 49 6426 9231 0 fax 31 ...

Reviews: