background image

E§§HNIKA

ENGLISH

OWNER’S INSTRUCTIONS
MANUAL DE INSTRUCCIONES
MANUEL D’UTILISATION
ISTRUZIONI PER L’USO
MANUAL DE INSTRUÇÕES
GEBRAUCHSANWEISUNG

O¢H°IE™

Split-type Room Air Conditioner 

(Cool and Heat)

Aire acondicionado doméstico sistema Split 

(Refrigeración y Calefacción)

Climatiseur de type Séparé 

(Refroidissement et Chauffage)

Condizionatore d’aria per ambienti ad unità Separate 

(Raffreddamento e Riscaldamento)

Aparelho de ar condicionado tipo Split 

(Refrigeração e Aquecimento)

Geteilte raumklimaanlage 

(Kühlen und Wärmen)

¢IAIPOYMENO K§IMATI™TIKO ¢øMATIOY

(æ‡Í˘ Î·È £¤ÚÌ·ÓÛ˘)

ESP

AÑOL

FRANÇAIS

IT

ALIANO

POR

TUGUÊS

DEUTSCH

E S F I P D G DB98-08672A(6)

AQ07P8GE
AQ07PBGE
SH07ZPG
SH07ZPGA
AQ09P8GE
AQ09PBGE
SH09ZPG
SH09ZPGA
AQ12PBGE
AQ12PGGB
AQ12PGGE
SH12ZPG
SH12ZPGA
AQ18P0GB
AQ18P0GE
SH18ZP0
SH18ZP0A
AQ24P6GB
AQT24P6GE
SH24TP6
SH24TP6A

Indoor unit

UQ07P8GE
UQ07PBGE
SH07ZPGX
SH07ZPGAX
UQ09P8GE
UQ09PBGE
SH09ZPGX
SH09ZPGAX
UQ12PBGE
UQ12PGGB
UQ12PGGE
SH12ZPGX
SH12ZPGAX
UQ18P0GB
UQ18P0GE
SH18ZP0X
SH18ZP0AX
UQ24P6GB
UQT24P6GE
SH24TP6X
SH24TP6AX

Outdoor unit

Summary of Contents for AQ07P8GE

Page 1: ...ho de ar condicionado tipo Split Refrigera o e Aquecimento Geteilte raumklimaanlage K hlen und W rmen IAIPOYMENO K IMATI TIKO MATIOY ESPA OL FRAN AIS ITALIANO PORTUGU S DEUTSCH E S F I P D G DB98 0867...

Page 2: ...orized service personnel DANGER Provide occasional ventilation during use Do not direct air flow at fireplaces or heating apparatus Do not climb on or place objects on the air conditioner Do not hang...

Page 3: ...13 Airing Your Room 14 Selecting Energy Saving Mode 15 Generating Anion 16 Adjusting the Air Flow Direction Vertically 17 Adjusting the Air Flow Direction Horizontally 17 PROGRAMMING YOUR AIR CONDITI...

Page 4: ...the temperature on the display N N N No o o ot t t te e e e Indoor Unit Air filter under the grille Air flow blades outlet Remote Control Sensor On Off switch Timer indicator Fan speed setting Sleep T...

Page 5: ...on Valve inside Outdoor Unit SH07ZPGX SH07ZPGAX SH09ZPGX SH09ZPGAX UQ12PGGB UQ12PGGE SH12ZPGX SH12ZPGAX Air Inlet Rear Air Outlet Connection Valve Outdoor Unit UQ18P0GB UQ18P0GE SH18ZP0X SH18ZP0AX UQ2...

Page 6: ...nergy saving Anion button Energy saving button Turbo button Timer Set Cancel button Digital i On Off button Temperature setting Air flow direction Turbo mode Sleep mode On Off button Temperature adjus...

Page 7: ...ake full advantage of the unit s features The booklet is organized as follows The following figures are shown on pages from 4 to 6 Indoor and outdoor units Remote control buttons and display They will...

Page 8: ...battery with on the remote control 1 2 Close the cover by sliding it back until it clicks into place 3 Use two AAA LR03 1 5V batteries Do not use old batteries or different kinds of batteries togethe...

Page 9: ...ndoor unit beeps each time you press the button The air conditioner runs in AUTO mode 2 You can change modes at any time If necessary press the On Off button Result The operation indicator on the indo...

Page 10: ...any time N N N No o o ot t t te e e e To adjust the temperature press the button one or more times until the required temperature is displayed Possible temperatures are between 18 C and 30 C inclusiv...

Page 11: ...ange modes at any time 3 To adjust the temperature press the button one or more times until the required temperature is displayed Possible temperatures are between 16 C and 30 C inclusive Result Each...

Page 12: ...hts up The air conditioner starts up in the mode selected when the unit was last used The indoor unit beeps 2 Press the button Result The temperature and fan settings are adjusted automatically The ai...

Page 13: ...ally after three minutes 2 If the is not displayed at the top of the remote control press the button on the remote control one or more times until it appears Result The indoor unit beeps each time you...

Page 14: ...of the remote control press the button on the remote control one or more times until it appears Result The indoor unit beeps each time you press the button The air conditioner runs in FAN mode The tem...

Page 15: ...C cancel the Energy saving mode before adjusting the temperature 6 To control the direction of the air flow refer to page 17 5 To select the fan speed press the button one or more times until the requ...

Page 16: ...ioner generates anion The indoor unit beeps 2 If you wish to stop the Anion function press the button again Result The air conditioner is reset automatically to the previous mode temperature and fan s...

Page 17: ...r air flow blade on the bottom of the unit thus increasing the efficiency of the air conditioner 1 Press the button one or more times as required Result The outer blade is adjusted vertically RECOMMEN...

Page 18: ...nclusive 1 Press the Set Cancel button to complete the setting Result The remaining time is displayed Blinking of the timer indicator stops The selected mode and the temperature on the display disappe...

Page 19: ...o complete the setting Result The remaining time is displayed Blinking of the timer indicator stops The air conditioner will switch off automatically when the counter displayed on the remote control r...

Page 20: ...e controlled as indicated in the illustrations below Cooling The desired temperature is increased by 1 C every hour When it has been increased by 2 C after two hours the temperature is maintained for...

Page 21: ...on before you wish to use the room Frost When outside temperatures are low and humidity is high frost may form in the outdoor unit when heating is selected If this happens The heating operation is sto...

Page 22: ...cur if the heat exchanger freezes High humidity levels Water may condense on and drip from the surface of the indoor unit if it is used for long periods E 22 Operating Your Air Conditioner Without the...

Page 23: ...in front of the outdoor unit Check that the required temperature has been set correctly Increase the fan speed If the air flow is directed upwards use the remote control to direct it downwards Check t...

Page 24: ...off the breaker used for the unit 2 Slide the upper front grille up slightly then open the grille by pulling right and left sides of the grille 1 Slide the lower front grille down 4 Lift out the botto...

Page 25: ...nit AQ07P8GE AQ07PBGE SH07ZPG SH07ZPGA AQ09P8GE AQ09PBGE SH09ZPG SH09ZPGA AQ12PBGE AQ12PGGE SH12ZPG SH12ZPGA AQ18P0GE SH18ZP0 SH18ZP0A AQT24P6GE SH24TP6 SH24TP6A AQ12PGGB AQ18P0GB AQ24P6GB 220 240V 50...

Page 26: ...URED BY ESTE AIRE ACONDICIONADO HA SIDO FABRICADO POR CE CLIMATISEUR EST FABRIQUE PAR QUESTO CONDIZIONATORE D ARIA PRODOTTO DA ESTE APARELHO DE AR CONDICIONADO FABRICADO POR DIESE KLIMAANLAGE IST FABR...

Reviews: