background image

Forced Mode: Press both buttons (Energy 
Saver– Fridge) 

simultaneously

 (No sound 

when  both buttons are pressed at the same 
time) ‘til it beeps and goes blank, 8-12 seconds 

 

Fast Track Troubleshooting 

IMPORTANT SAFETY NOTICE

 – 

“For Technicians Only”

  This service data sheet is 

intended for use by persons having electrical, electronic, and mechanical experience 
and knowledge at a level generally considered acceptable in the appliance repair trade.  
Any attempt to repair a major appliance may result in personal injury and property 
damage.  The manufacturer or seller cannot be responsible, nor assume any liability for 
injury or damage of any kind arising from the use of this data sheet. 

Models Covered:  
RF267AA**/XAA    

 

French Door Refrigeration

 

Press Freezer button a 
third time to Force Defrost 
for Fridge & Freezer, 
measure defrost voltages  
at main  PCB 

Wait 5 seconds between button pushes

 

Press Freezer button a 
second time to Force 
Defrost of Fridge, meas-
ure defrost voltage  at 
main PCB 

Press Freezer button one 
time at the Test Mode to 
Force Compressor Run, 
measure fan and  com-
pressor voltages at main 
PCB 

Self Diagnosis: Press both buttons 
(Energy Saver– Alarm) 

simultaneously

 (No 

sound when both  buttons are pressed at 
the same time) ’til the display quits blink-
ing and beeps, 8-12 seconds, then release 
and read Fault Codes.                                  
This will also cancel the Fault Mode cre-
ated by self-diagnosis at power up. 

 

Publication #  tsRF267AA  Creation Date 08/12/2010

 

Sealed System 

Component Value Chart 

Sales Mode,  No Compressor Operation 
Press Energy Saver & Freezer temp buttons         
simultaneously for 3 sec ( you will hear a “Ding 
Dong”) to remove or put into Sales Mode. When in 
the Sales Mode the Display will show "OF" "OF" 
Removing power will not cancel this mode.

 

Component

Resistance Wattage Voltage

Freezer Defrost Heater

60

240

120vac

Fridge Defrost Heater

120

120

120vac

French Mullion Heater

1800

8

120vac

Ice Duct Heater

3600

4

120vac

Dispenser Heater

7200

2

120vac

Water Tank Heater

72

2

12vdc

Sensors

2.5k

-89k

N/A

1~4.5vdc

Fans

N/A

N/A

7~12vdc

Compressor 

 Condenser 

Side Cluster 

 Hot Pipe

 

Dryer 

 R Capillary 

 R Evaporator 

 F Evaporator 

  

Suction Pipe 

 Compressor

 

Refrigerant Charge                      

R134a     5.64 oz.

 

NOTICE:                          

RF267AA**   01/09                     

Parts Change: Refer to bulletin. 

All Water Tank Parts & Door 

Dispenser Ass’y Parts 

1

 

 

1

Reviews: