background image

6

5

4

3

2

 

 

 

Key Tag Registration

3. Exit Registration Mode

In order to open from indoors, 

push the Inner Handle downwards to unlock.

SHP-H20

PTMP5800ONTB ED:00

Door open /

Warning LED

Touch the out body unit number pad

to lock the door. 

smarthome.samsungsds.com

Easy access with PIN code and Key tag

Convenient Door Opening

Silent Mode

When going in or out, the sound of the
key entering and door opening will be 
suspended. 

  

Automatic Key Tag Reading Function

When a user places a key tag on the reader, 
it automatically recognizes the key tag.

2-Step Authentication Mode

Both PIN code and key tag need to be authenticated  
to open the door, ensuring a higher level of security.

Privacy Mode

Unlocking the door from outside is prevented while
someone is inside.

Away Mode

After a user goes out, this function generates 

alarm sound when an attempt is made to open  
the door from the inside.

High Temperature Alarm 

When the built-in sensor detects abnormal 
high-temperature, the alarm will be triggered, 
and the doorlock will be automatically unlocked  
to allow fast escape.

  The information of this user manual is subject to change without any 

notices to improve the performance of this product. 

  Customer’s improper installation may result in a additional service costs.

We highly recommend professional installation. 

Warning

 Safety Precautions

This section contains important information to ensure the user’s safety 
and prevent potential damage to property.  
Please, read this section carefully and use the product accordingly.

•  The installation and repair should be done 

by the professional installer or service 

person. 

•  Do not install the product in the place 

where the gap between the door and the 

frame is 5 mm or more.

•  Long-term exposure to direct sunlight  

may cause a crack on its touch pad.  

Avoid exposure to direct sunlight.

•  Do not use the excessive force or sharp 

objects to push the lock buttons, as this 

can damage the product.

•  Do not operate the product with wet 

hands, and keep liquids such as water 

or drinks away from the product, or the 

product may malfunction or be damaged.

•  Do not use water, benzene or alcohol 

when cleaning the product, but use a soft 

dry cloth.

•  Make sure that the door is completely 

closed when going outside.

•  Make sure that no unauthorized person 

has the access to the PIN code .  

Change it regularly.

•  Be sure to correctly match the battery 

polarities (+/-) when installing the batteries. 

Wrong direction of battery polarities may 

cause the battery liquid leakage or the burst 

of them.

•  When the battery replacement alarm 

melody is generated, use all new batteries 

instead of the existing batteries.

•  According to the wireless communication 

environment, its battery may consume 

much.

•  

Interference in wireless communication 

may occur when this product is used, or 

radio interference may occur from other 

devices

.

•  As this radio system may have radio 

interference during the operation, it cannot 

provide a service for human lives.

•  Too much dew condensation may affect the 

performance of this product.

•  Keep 20 cm or longer away from this 

product when using it.

 

 

RF Key Tag : 2EA

Exterior Unit

 Interior Unit

 

User Manual

 ‘AA’ Batteries (LR6)

 

Handle Shaft Spring

  

Handle Shaft, Installation Screws

 

Installation Manual

Dust Box

Strike Plate

Mortise

The product components may vary depending on the installation 
environment.

Product Components

Entry Complete/

Silent Mode Touch Button

[ CLOSE / DOUBLE LOCK ] 
Button

Interior Unit Handle

Dead Bolt

Latch Bolt 

Battery Cover

[ Registration ] 
Button

1.5V AA Batteries

Reset Button

Key Tag Reader

Number Pad

Away Mode Touch Button

Battery Replacement Alert

 LED

External Power

Exterior Unit Handle

  Silent Mode 

Before entering the PIN code, press the [

] button and enter the PIN code, then both  

the sound of the key entering and the door opening will be muted. 

It is a useful function if you do not want to disturb neighbors when you go in and 

out at night.

1. Randomizer Mode

2. Common Mode

When the number pad lights up, enter the
PIN code and press the [

] button.

Opening the Door from Outside (PIN code)

 

When purchased, the product is set to Multi-leveled Security Code Entry Mode 

initially. Please, refer to ‘Multi-leveled Security Code Entry Mode setting’ for 

Common Mode setting.

   

PIN code must be entered after the light is on, and if does not, touch [Number Pad]  

and re-enter.

   

To cancel, press [   ]  button and re-enter.

   

If the PIN code is wrong 5 times, “peep” warning alarm will sound 20 times and 

the system will shut-down for about 3 minutes. When malfunction happens,  

“beep” will sound every 10 seconds, and stop mode will be turned 

off automatically after 3 minutes with multiple ‘beeps’.

Note

Touching [Number 

Pad] will light up 

the number pad.

Touching [ Number Pad ]  
will light up the number pad. 

When two arbitrary 

buttons are lighted, 

press the buttons 

in order.

When the numbers on the 

number pad are lighted, enter 

the PIN code  and press the 

[

] button.

Success:

Be be be beep

Success:

Fail:

DING DONG DING DONG

BE BE BE BEEP

Success:

Fail:

DING DONG DING DONG

BE BE BE BEEP

Fail:

Ding dong ding dong

Exterior Unit Parts

Interior Unit Parts

Mortise

Place the  key tag on the key tag sensor.  
The door will be opened after 1 second. 

A locked door can be opened from outside by using a key tag.

Place the registered key tag on the key tag sensor.

Opening the Door from Outside (Key Tag)

  

 

 

Note

   

When the key tag sensor does not recognize the key tag, touch 

the number pad and put the key tag on the key tag sensor to  

open the door.   

Opening the Door from the Inside

Automatic Locking Setting

Manual Locking Setting

Automatic Locking Setting

Manual Locking Setting

The door is automatically locked 2 seconds after the 

door is closed.

The door is locked when the 

[ CLOSE / DOUBLE LOCK ] button 

from the inside is pressed.

Locking the Door from the Inside

The door is automatically locked 2 seconds after the 

door is closed.

Locking the Door from Outside

All registration and setting are activated only when the door is opened.

Initialization (PIN code , Key Tag) 

 

   

2. Enter the Numbers for Initialization 

All registered data (PIN code , Key tag) are deleted. 

After initialization, the PIN code  is set to ‘1234’, and the registered  key tag 

data are erased. Please register a new PIN code  after initialization.

When the number pad is lighted, enter 

‘4560852580’ and then press the  

[

] button.

DING DONG 

 

DING DING 

Success:

DING DONG DENG

Fail:

DING DONG DING DONG

DING DONG 

DING DONG DENG

DING DONG DENG

A user can register a PIN code  (4 to 12 digits), and only one PIN code canbe   

registered, The default PIN code  is “1234.”

Change the PIN code 

  To prevent an intrusion, it is recommended to make a PIN code with 6 or 

more digits. (Each digit number ranges from 0 to 9.)

  Manage your master PIN code with care so that unauthorized people will not 

have access to it. Regularly changing your PIN code can reduce the risk of it 

being leaked.

  A registered PIN code cannot be deleted. Register a new PIN code . 

  To make sure the PIN code has been properly registered, check the new 

PIN code and close the door.

  If checking the new PIN code fails, initialize the key information (see page 5) 

to initialize the PIN code, and change the PIN code again.

Warning

Enter the new PIN code  (4 to 12 digits) 

and press the [

] button.

1. Press [Register] Button

DING DONG 

1. Press [Register] Button

1. Press [Register] Button

 

2. Enter a New PIN code

During registration, already registered key tags will be deleted.  

Please register all key tags at once.

Up to 20 key tags can be registered. (Only ISO14443 A Type is available.)

 

2. Place the Key Tag Reader 

DING DONG DENG

Place the key tag to be registered  

on the key tag reader of the outer body. 

You will know the key tag has been  

registered when “DING DONG DENG”  

sounds.

If you want to end this process, 
press the [Register] button 
of the inner body shortly.

● 

 

To register multiple key tags, lightly place another key tag to   

the Key tag reader within 20 seconds after registering the previous  key tag. 

● 

Only the key tags provided by Samsung SDS can be used.

  

Samsung SDS will not take responsibilities for any problem that may 

occur because you used an authentication means other than the 

key tags that we provided.

Warning

Open the battery cover of the inner body 

and press the [Register] button shortly.

Open the battery cover of the inner body 

and press the [Register] button shortly.

Open the battery cover of the

inner body and press the [Register]

button for 3 seconds. 

Reviews: