Model: PCRL80    PCRL80F

RECESSED FAN LIGHT

WARNING

READ AND SAVE THESE INSTRUCTIONS

Installer: Leave this manual with the homeowner.

CAUTION

CLEANING & MAINTENANCE

OPERATION

PLAN THE INSTALLATION

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

For quiet and efficient operation, long life, and attractive appearance - lower or remove grille and vacuum interior of unit with 

the dusting brush attachment.

The motor is permanently lubricated and never needs oiling. If the motor bearings are making excessive or unusual noises, 

replace the motor with the exact service motor. The impeller should also be replaced.

1. Do not use in a cooking area.

2. Two ways to connect ductwork to a factory-shipped unit.

1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors. 

2. This product is designed for installation in ceilings up to a 12/12 pitch (45 degree angle). Duct connector must be horrizontal.             

    *  DO NOT MOUNT THIS PRODUCT IN A WALL. 

3. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off 

     power unit. 

4. Please read specification label on product for further information and requirements. 

Use a 2-function wall control to operate this fan. See “Connect Wiring” for details. 

ROOF CAP*

(with built-in

damper)

ROUND

DUCT*

WALL CAP*

(with built-in

damper)

*

 Purchase

separately

POWER

CABLE*

INSULATION*

(Place around and

over Fan Housing.)

Seal gaps

around

Housing.

FAN

HOUSING

ROUND 

ELBOW(S) *

Seal duct

joints with

tape.

Keep duct

runs short

a). Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer.

b). Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent 

power from being switching on accidentally. When the service disconnecting means cannot be locked, securely fasten a 

prominent warning device, such as a tag, to the service panel. 

c). Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and 

standards, including fire-rated construction codes and standards. 

d). Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning 

equipment to prevent backdrafting. Follow the heating equipment manufacturer’s guideline and safety standards such as 

those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration 

and Air Conditioning   Engineers (ASHRAE), and the local code authorities. 

e). When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. 

f). Ducted fans must always be vented to the outdoors. 

g). Acceptable for use over a tub or shower when connected to a GFCI (Ground Fault Circuit Interrupter) - protected branch 

circuit (ceiling installation only). 

h). This unit must be grounded. 

i). Not for Use in Kitchens.

j). Install Fan At Least 2.5 m (8.2 feet) Above The Floor.

k). To reduce risk of fire and to properly exhaust air, be sure to duct air outside – Do not vent exhaust air into spaces 

within walls or ceilings or into attics, crawl spaces, or garages

l).  WARNING: To Reduce The Risk Of Fire Or Electric Shock, Do Not Use This Fan With Any Solid-State Speed Control 

Device.

m). The fan must not be installed in a ceiling thermally insulated to a value greater R40.

Summary of Contents for PCRL80

Page 1: ...by the manufacturer If you have questions contact the manufacturer b Before servicing or cleaning unit switch power off at service panel and lock the service disconnecting means to prevent power from being switching on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel c Installation work and electrical w...

Page 2: ... 597 Screw A Screw B 1b Extend the hanger bars to the width of the framing Position the fan with the hanger bar tabs aligned with the bottom edge of the framing holding the ventilator in place Secure hanger bars to framing using one screw on each end of hanger bar Attach set screws to lock bar hangers in place Insulated flexible duct is recommended for the quietest possible installation If rigid d...

Page 3: ...right 3 Remove the lamp base 4 Pull the duct system so that you can see the blower system Remove the screws Lamp base Blower system Wing nut Lamp base 5 Remove the screws as shown in the right 6 Take the blower system out of the housing 7 Replace the broken parts Remove the screws Remove the screws Run 120 Volts AC house wiring to the fan Use only UL approved connectors not included to attach the ...

Page 4: ...oes not cover normal maintenance and service or any parts that have been subject to misuse negligence accident improper maintenance or repair faulty installation or installation contrary to recommended installation instructions S P s obligation to repair or replace at S P s option shall be the purchaser s sole and exclusive remedy under this warranty No labor or materials are covered by this warra...

Reviews: