SLP 32RZ - Code Nr. 01325, SLP 33RZ - Code Nr. 01335 

Supplied equipment 

Installation

 

6

4

min 150 mm

5

8

1

2

3

7

length of
vertical plumbing

1 - water inlet to the urinal
2 - electronics with radar senzor
3 - outlet fiting with sealing
4 - waste outlet Ø 50 mm
5 - power input 230V/50Hz
6 - urinal
7 - waste siphon
8 - electromagnetic valve

Ø 50 mm
waste
outlet

Ø = 14

Ø = 14

150

230V/50 Hz

150

water inlet

SLP 32RZ = 200
SLP 33RZ = 240

SLP

 32R

Z = 42

0

SLP

 33R

Z = 37

5

SLP

 32R

Z = 18

0

SLP

 33R

Z = 21

5

SL

P

 32R

Z = 58

5

SL

P

 33R

Z = 66

0

Mounting instructions

 

Automatic urinal radar flushing system SLP 32RZ, SLP 33RZ

 

Function

minimum use time 10 sec.

after 6 hours non use

Properties

flushing time 0,5 - 15,5 sec

using time 6 - 15 sec