background image

Purity is Premium

PIPELESS™ PORTABLE FOOT BATH WITH SEAL-LESS JET TECHNOLOGY

OWNER’S MANUAL

Models: SFB2-S115-XX (115v, 60Hz) 2 Jet – Dual Speed

Summary of Contents for PIPELESS SFB2-S115-XX

Page 1: ...Purity is Premium PIPELESS PORTABLE FOOT BATH WITH SEAL LESS JET TECHNOLOGY OWNER S MANUAL Models SFB2 S115 XX 115v 60Hz 2 Jet Dual Speed ...

Page 2: ...ility for quick and easy system disinfection Please read and follow all of the instructions contained in this Manual before installing operating or maintaining your new SANIJET Pipeless Portable Foot Bath Before proceeding please take a few minutes to complete the warranty registration enclosed in your Owner s packet and submit it to SANIJET at the address provided on the form If you have question...

Page 3: ...formation 1 Limited Commercial Warranty 2 Safety 3 Electrical 4 Features and Specifications 5 Operating Instructions 7 Dry Run Protection 8 How To Drain 9 Cleaning and Care 10 Troubleshooting 12 Table of Contents ...

Page 4: ...t do not install the unit SANIJET s responsibility for shipping damage ceases upon delivery of the product in good condition to the carrier It is the responsibility of the recipient to inspect the packaging for damage Any damage claims must be filed with the carrier within 2 business days from receipt of shipment All returns will be refused unless accompanied by a Return Material Authorization RMA...

Page 5: ...his warranty does NOT cover a metallic plated hardware light bulbs or fading from exposure to direct sunlight b failure damage or defect caused by any of the following after the product leaves SANIJET s factory mishandling abuse misuse neglect accident or natural disaster normal wear and use that does not affect the product s function failure to maintain the product as recommended by SANIJET See O...

Page 6: ...en into water Unplug immediately 2 DO NOT drop or insert anything into any jet opening 3 DO NOT operate this unit without the complete jet assembly installed or without water filled 1 in 3 cm above the jets 4 DO NOT overfill the basin 5 DO NOT stand on or in the basin or on the foot rest 6 DO NOT leave this appliance unattended when in operation 7 Keep the electrical cord away from heated surfaces...

Page 7: ...ot bath from the carton and retain the shipping carton and packing material to reuse in case service becomes necessary DO NOT lift the foot bath by its handle or electrical cord GROUNDING INSTRUCTIONS This unit must be grounded The integral GFCI should be tested on a routine basis To test the GFCI push the test button The GFCI should interrupt power Push the reset button Power should be restored I...

Page 8: ...gh Performance Ultra Quiet Pipeless Jets Advanced Seal less Technology Designed for Maintenance Free Use Complete Hygiene with Simple Five Minute Disinfection Protocol Two Piece Lid with Client Foot Rest for Comfort Rolling Casters and Easy to Use Handle Discharge Pump and Fill Hose Durable High Gloss Acrylic Construction in White or Biscuit ...

Page 9: ...0 0 51 cm x Length 27 0 69 cm x Height 15 0 38 cm Material Structurally reinforced cast acrylic Operating Capacity 4 5 Gallons 17 L Approximate Ship Weight 42 lbs 19 kg Water Flow Rate 14 gallons per minute 53 L Electrical Requirements 115 VAC 60 Hz 15 amp dedicated GFCI service 10 ft 3 m 16 3 power cord included DIMENSIONS 27 69 cm 20 51 cm 15 38 cm ...

Page 10: ...om splashing onto the floor 3 Verify that the unit s electrical cord is connected to a GFCI protected electrical outlet 4 To start or stop this appliance turn the dial switch to the ON or OFF position 5 Bath additives including oil based products can be used in a SANIJET Pipeless Pedicure Bath since their residue can be easily cleaned CAUTION Use only low foaming additives and do not use products ...

Page 11: ...n back ON If the motor does not sense a load after 8 seconds it will shut off again for another 15 seconds The motor will repeat this sequence a total of 10 times before going into standby mode Resetting the motor requires cycling the main power to the motors OFF and then back ON unplug system and wait 5 seconds then plug power supply back in again SAFETY SHUTOFF SENSOR The Pipeless Pedicure Bath ...

Page 12: ...y continue running the pump while removing it from the interior of the foot bath and place it in the sink or chosen draining area As soon as the pump and hose are both fully in the sink unplug the power cord to turn off the discharge pump Fresh water can be used to rinse out the tank during the draining procedure See Image 2 WARNING Do not leave the pump running in the draining area or in a dry fo...

Page 13: ...requiring quick cleaning between treatments we recommend a second set of clean jet assemblies for quick replacement IMPORTANT Always refer to your state and local guidelines for cleaning requirements NEVER USE abrasive cleaners on any surface area After each use disinfect the system with the recommended disinfection procedures for maximum sanitation BEFORE USE check the jet assembly is properly in...

Page 14: ...based cleaner Disinfect using a 5 1 water bleach solution Thoroughly rinse all cleaning solution residue with water Air dry Approved Cleaners DISPATCH Hospital Cleaner Disinfectant Clorox Disinfecting Wipes LYSOL Disinfectant Fantastik When using these cleaners we strongly recommend rinsing the surface with clean water in order to remove any cleaning residue HOW TO STORE THE FOOT BATH 1 Replace th...

Page 15: ...n 3 Jet Assembly Alignment a Check jet assembly is locked in the 9 o clock or 3 o clock run position in the jet motor case b Ensure magnetic impeller rotor is correctly installed in the jet motor case c Inspect separator plate to ensure proper assembly in the jet escutcheon d Inspect separator plate to ensure magnets 2 are present and properly installed EXCESSIVE NOISE 1 Remove jet assembly escutc...

Page 16: ...120125 SANIJET Customer Service Department Toll Free 877 934 0477 Toll Free Fax 214 352 0348 E mail info sanijet com 6200 Maple Avenue Dallas Texas 75235 sanijet com ...

Reviews: