background image

Sanuvox Technologies Inc, © 2020 All rights reserved. August 2020 EN v.4

Instruction Manual

Photos illustrating products are non contractual.

SANUVAIR

®

 S100

AIR PURIFICATION UNIT

Commercial Model

IMPORTANT SAFETY INSTRUCTIONS

READ AND SAVE THESE SAFETY INSTRUCTIONS BEFORE USING THIS PRODUCT.

Read and follow all instructions contained in 

this manual before using the product. Failure 

to comply with these instructions may result 

in personal injuries or damage to the unit or 

system.

1.  Installation and servicing of air conditioning 

and related equipment can be hazardous due 

to systems pressure and electrical components. 

Only trained and qualified service personnel

 

should install, repair or service equipment.

2.  Untrained personnel can perform basic 

maintenance functions such as replacing 

lamp(s)  and/or  filter(s).  All  other  operations 

should be performed by trained service 

personnel.

3.  When working on the unit or system, observe 

precautions in the literature, tags and labels 

attached to the unit or system, and all other 

safety precautions considered as best practices 

in the HVAC industry.

4. When applicable, local regulation may 

comprise more restrictive installation and/or 

certification requirements. The afore mentioned 

requirements prevail on those of this document 

and the installer agrees to conform to these at 

his own expense.

5.  Follow all the safety instructions outlined in this 

document and respect all local and national 

codes applicable.

6.  Never expose eyes or skin to ultraviolet light 

from any source.

 Therefore, 

before installing 

or performing maintenance on the unit or 

system,  TURN OFF AND DISCONNECT the 

unit or system from all power sources (there 

may be more than one switch to disconnect).

 

 CAUTION: Electrical shock may cause 

personal injuries or possibly death.

7.  UV  rays  may  destroy  certain  types  of  filters 

(polymer or plastic); please keep the unit or 

system light away from shining directly on 

plastic.

8.  When installing or performing maintenance on 

the UV unit or system, it is recommended to 

wear safety glasses and gloves. In order to 

avoid reduced performance of lamp(s), do not 

touch lamp glass without gloves.

9.  UV lamps contain a small quantity of mercury: 

if a lamp breaks, clean and dispose of with 

care. UV lamps can be disposed/recycled after 

use,  as  any  other  fluorescent  lamps.  Contact 

and  follow  your  local  and  national  authorities’ 

specific instructions.

10. 

Use  only  specified  SANUVOX  branded 

replacement UV lamps with your unit or 

system. Use of any other lamps will void your 

warranty and can result in damage to the unit, 

system and/or lamp(s).

11. Most UV units or systems are not waterproof. 

DO NOT INSTALL OUTDOORS unless 

specified otherwise.

SAVE THESE INSTRUCTIONS

Installation Date:  _______________   Installed by:  _________________
Installer Contact Info.:  _________________________________________

REGISTER 

YOUR WARRANTY

 

ONLINE AT 

www.sanuvox.com

Summary of Contents for SANUVAIR S100

Page 1: ...ollow all the safety instructions outlined in this document and respect all local and national codes applicable 6 Never expose eyes or skin to ultraviolet light from any source Therefore before installing or performing maintenance on the unit or system TURN OFF AND DISCONNECT the unit or system from all power sources there may be more than one switch to disconnect CAUTION Electrical shock may caus...

Page 2: ...Setup Installation Ceiling Mounted 4 Step by Step Setup Installation Wall Mounted 6 OPERATION 7 How to Operate your Product 7 MAINTENANCE 8 How to Replace Lamp s 8 Step by Step Lamp Replacement 8 How to Clean your Product 9 Step by Step Filter Cleaning 9 STORAGE 10 ULTRAVIOLETS UVV UVC 10 ELECTRICAL RATINGS POWER CONSUMPTION AVAILABLE VOLTAGE 10 TROUBLESHOOTING 10 What you will need 10 Problems So...

Page 3: ...nternal fan circulates air through the air purifier The SANUVAIR S100 is designed to treat up to 500 square feet of space per unit A Air inlet vent B Filter door with mesh C Security switch D Filter E UV Lamp F Fan G Unit cover H Air outlet vent SETUP INSTALLATION What you will need A utility knife to unpack all components a stepladder to reach the celling or wall properly a Phillips No 2 screwdri...

Page 4: ...it out of its box and install the support anchors required to support the unit by screwing them directly to the unit A Sliding door side near horizontal support bracket B Beveled side mesh angled support bracket Then lay the unit on a flat surface with the access doors facing up NOTE Keep box in case of return under warranty STEP 1 STEP 2 STEP 5 5 Install lamp Open the unit by sliding its cover to...

Page 5: ...device support anchors against the tile and the ceiling support 11 Replace the cut part of the suspended ceiling tile to hide the opening Then right up against the unit install a 24 T bracket Your new SANUVAIR S100 is now ready to operate so you can enjoy great air quality for you and your colleagues 6 Install Filter While the unit cover is still open pull on the non mesh end to gain access to the...

Page 6: ...ted the UV lamp should you break the security seal on the underside of the cardboard sleeve 4 Carefully slide the UV lamp out from the cardboard sleeve Be sure to wear the cotton gloves included guaranteeing a clean lamp free from fingerprints NOTE Fingerprints on the lamp will negatively impact the UV output of the lamp STEP 3 STEP 4 STEP 5 STEP 6 5 Install lamp Open the unit by sliding its cover...

Page 7: ...he fan settings are adjusted to your liking make sure to close the unit cover properly OPERATION How to Operate your Product If wired directly to a dedicated power source the SANUVAIR S100 will operate continuously If wired in parallel with other devices such as overhead lighting the SANUVAIR S100 will operate only when the circuit is energized The internal fan circulates air through the device Ro...

Page 8: ...s doors facing up Besides this option is preferable for a wall unit 1 Open the unit by sliding down its cover to gain access to the lamp location 3 Prepare the new lamp Remove the contents from packaging Only after you have visually inspected the UV lamp should you break the security seal on the underside of the cardboard sleeve 4 Carefully slide the new UV lamp out from the cardboard sleeve Be su...

Page 9: ...ed on the ceiling or wall Another option is to remove the unit from the ceiling or wall and then access the filter with the unit lying on a flat surface with the access doors facing up Besides this option is preferable for a wall unit 1 Open the unit by sliding down its cover and pull on the non mesh end of the filter door to gain access to the filter location CAUTION When unit is wall mounted its...

Page 10: ...ORIGINAL PLACE OF PURCHASE DO NOT ATTEMPT TO OPEN THE PRODUCT OR TAMPER WITH ITS COMPONENTS WITHOUT CONTACTING CUSTOMER SERVICE FIRST DOING SO MAY VOID YOUR WARRANTY AND CAUSE PERSONAL INJURY OR DAMAGE TO THE PRODUCT TROUBLESHOOTING If your product is not working properly refer to the following What you will need A stepladder to reach to celling or wall properly and an ohmmeter Problem Possible Ca...

Page 11: ...s facing up Besides this option is preferable for a wall unit 1 Open the unit by sliding down its cover to gain access to the lamp location 3 Using an ohmmeter place 1 probe on 1 of the 4 pins and by sensing the 3 remaining pins one should have continuity Make sure the 2 remaining pins also have continuity When both sets of pins test good for continuity it can be assumed that the lamp is good STEP...

Page 12: ...be defective in material or workmanship C This warranty does not cover damage resulting from any unauthorized attempts to repair or from any use not in accordance with the instruction manual D This warranty does not cover the filters pre filters or other accessories if included except for material or workmanship defects Call us toll free at 1 888 726 8869 or email info sanuvox com Please be sure t...