background image

INSTRUCTION MANUAL

MPX-MS92P

B/W Multiplexer

English

GB 

Schwarzweiß Multiplexer

Deutsch

Multiplexeur Noir et Blanc

Français

Blanco y negro Multiplexor

Español

Multi distributore in bianco e nero

Italiano

 

About this manual

Before installing and using this unit, please read this manual
carefully. Be sure to keep it handy for later reference.

Über diese Anleitung

Lesen Sie bitte diese Bedienungsanleitung vor der Installation
und der Verwendung des Gerätes sorgfältig durch. Bewahren
Sie die Anleitung zum späteren Nachschlagen auf.

À propos de ce manuel

Avant d’installer et d’utiliser cet appareil, veuillez lire ce manuel
attentivement. Assurez-vous de le garder à portée de la main
pour référence ultérieure.

Acerca de este manual

Antes de instalar y usar este aparato, lea detenidamente este
manual. Asegúrese de guardarlo a mano para futuras
referencias.

Nota su questo manuale

Leggere attentamente questo manuale prima di passare
all’installazione ed all’uso di questo apparecchio.

L8FN5/XE (MPX-MS92P GB) 2000. 8. 31

Summary of Contents for MPX-MS92P

Page 1: ...ng vor der Installation und der Verwendung des Gerätes sorgfältig durch Bewahren Sie die Anleitung zum späteren Nachschlagen auf À propos de ce manuel Avant d installer et d utiliser cet appareil veuillez lire ce manuel attentivement Assurez vous de le garder à portée de la main pour référence ultérieure Acerca de este manual Antes de instalar y usar este aparato lea detenidamente este manual Aseg...

Page 2: ...ct to strong vibrations Avoid moving the multiplexer between cold and hot locations Do not place the multiplexer directly on top of a monitor TV as this may cause playback or recording problems Avoiding Electrical Shock and Fire Do not handle the power cord with wet hands Do not pull on the power cord when disconnecting it from an AC wall outlet Grasp it by the plug If any liquid is spilled on the...

Page 3: ...ive camera images in full screen mode or in a split screen 4 or 9 divisions Recorded pictures can also be displayed in a split screen The field switcher function can during recording display the images full screen or full screen sequentially The multi viewer function can during live images mode display the images in a split screen and record the images as displayed High speed switching up to singl...

Page 4: ... the button one more time to cancel 8 STILL button and indicator In full screen display mode press this button to freeze the displayed image Press the button one more time to cancel 9 SEQUENCE button and indicator In 4 divisions split screen or full screen display modes press this button for an automatic sequential full or 4 division split screen display of the pictures F MENU button see page 9 Pr...

Page 5: ...NATE 9 SENSOR ALARM OUT terminals 1 9 F ALARM IN Alarm signal input terminals The alarm triggers input to the unit are output at the AL pin of the CONTROL terminal G CONTROL terminal Pin Signal C Ground A RS485 terminal B RS485 terminal C Common AL Alarm output DC 5V C Common R1 Remote input 1 R2 Remote input 2 C Common SW Switching input DC 5V C Common Used for connection with a twisted pair cabl...

Page 6: ...round Ground ALARM input terminal Video input terminal Timelapse VCR sold separately Switching output terminal NOTE The camera signal input at each CAMERA IN terminal is throughput at the corresponding CAMERA OUT terminal The CAMERA IN terminals are automatically terminated at 75 Ω When no connection is made to the CAMERA OUT terminal the CAMERA IN terminal 75 Ω termination is made automatically W...

Page 7: ...eo sensor alarm indicator lamps could be laid out on a factory floor plan to give accurate indication of trigger location The terminals are normally open NO A trigger at the video sensor for one of the cameras will switch the signal to LOW A B RS485 To terminal A To terminal A Straight type cable Cross type cable Straight type 1 6 Cross type 1 2 3 4 5 6 1 2 3 4 5 6 Not used Not used Not used Not u...

Page 8: ...SW 2 SW 3 SW 4 SW 5 SW 6 SW 7 SW 8 220Ω 300Ω 360Ω 470Ω 680Ω 820Ω 1 2kΩ Camera 2 Camera 3 Camera 4 Camera 5 Camera 6 Camera 7 Camera 8 SW 1 220Ω Camera 1 SW 18 SW 19 SW 20 SW 21 SW 22 SW 23 SW 24 SW 25 1 8kΩ 2 2kΩ 3 3kΩ 4 7kΩ 7 5kΩ 13kΩ 27kΩ 68kΩ Not used 4 divisions split screen NEXT EXIT DISPLAY 3 2 SW 11 SW 12 SW 13 SW 14 SW 15 SW 16 SW 17 220Ω 300Ω 360Ω 470Ω 680Ω 820Ω 1 2kΩ VCR playback Live pi...

Page 9: ...ON To record live images in full screen or split screen 4 or 9 divisions 01 01 MONITOR SET MON SEQ TIMER 1 S QUAD SEQ TIMER 1 S MON SEQ MODE MODE1 MON MASK LIVE ON MON MASK VCR ON MULTI MODE OFF Monitor Menu setting screen Sent to the VCR for recording 01 02 03 01 02 03 MONITOR SET MON SEQ TIMER 1 S QUAD SEQ TIMER 1 S MON SEQ MODE MODE1 MON MASK LIVE ON MON MASK VCR ON MULTI MODE ON Monitor Menu s...

Page 10: ...de MULTI MODE set to ON NO ID will be displayed on screen NOTE In live picture mode and VCR playback mode there may be a slight vertical roll of the picture Menu Setting Mode see page 22 1 Press the MENU button to display the menu The buttons used for menu control are indicated below 2 NEXT button To select a sub menu in the CAMERA SET POSITION SET DISPLAY SET menus in order to set the title posit...

Page 11: ...attery To replace the battery please consult your dealer After the battery has been replaced press the ALL RESET button then in the CLOCK SET menu set the date and time see page 24 Depending on the battery usage it may become necessary to change it For replacement and disposal of the old battery please contact your dealer RESET FUNCTION The menus can be reset or cleared using one of the following ...

Page 12: ...NITOR SET menu see page 32 The camera SELECT indicators 1 9 light sequentially according to the displayed camera To cancel the sequential display mode Press the SEQUENCE button or the SELECT button ALARM OPERATION When an alarm trigger from a door bell an interphone etc is input at the rear panel ALARM IN terminals the alarm channel pictures and the camera number are displayed with EA External Ala...

Page 13: ...MODE OPERATIONS STEPS ON MONITOR Full screen operations see page 13 Multi display screen operations see page 15 4 divisions split screen operations see page 15 Full screen Still image Zoomed in still image STILL ZOOM ZOOM STILL 04 04 S 04 S 04 S 04 SZ 04 SZ 04 SZ 04 Zoomed in image Z 04 Z 04 Zoom range setting Press for 3 seconds or more SEQUENCE 4 Automatic sequential display 4 04 04 Press for 3 ...

Page 14: ...OOM button one more time To cancel the still image display mode Press the STILL button If another mode button is pressed the still image display mode is cancelled and the selected mode starts Example To zoom in the image from camera 3 1 Press the SELECT 3 button The camera 3 indicator lights the image from camera 3 is displayed full screen 2 Press the ZOOM button The ZOOM indicator flashes and Z f...

Page 15: ...e the zoom range frame to the desired area of the image 5 Press the SELECT 4 button The area selected by the zoom range frame is now zoomed in If necessary follow the same procedure to set the zoom range for the other cameras To cancel the zoomed in image display mode Press the ZOOM button If another mode button is pressed the selected mode starts Example To freeze the zoomed in image from camera ...

Page 16: ... sequential mode and speed set in the MONITOR SET menu see page 32 The camera SELECT indicators 1 4 5 8 9 light sequentially according to the displayed 4 divisions split screen To cancel the sequential display mode Press the SEQUENCE button or the SELECT button MULTI DISPLAY SCREEN OPERATIONS Press the MULTI button The 9 divisions split screen display mode will be selected NOTE The display positio...

Page 17: ...NITOR Full screen operations see page 17 Multi display screen operations see page 19 4 divisions split screen operations see page 19 Full screen Still image Zoomed in still image STILL ZOOM ZOOM STILL 04 04 S 04 S 04 S 04 SZ 04 SZ 04 SZ 04 Zoomed in image Z 04 Z 04 Zoom range setting Press for 3 seconds or more SEQUENCE 4 Automatic sequential display 4 04 04 Press for 3 seconds or more 4 SZ 04 SZ ...

Page 18: ...press the ZOOM button one more time To cancel the still image display mode Press the STILL button If another mode button is pressed the still image display mode is cancelled and the selected mode starts Example To zoom in the image from camera 3 1 Press the SELECT 3 button The camera 3 indicator lights the image from camera 3 is displayed full screen 2 Press the ZOOM button The ZOOM indicator flas...

Page 19: ...on If another mode button is pressed the selected mode starts While in zoomed mode if the SELECT button is pressed one more time depending on the movement of the subject the image may be more or less clear Pressing the SELECT button repeatedly will produce the following according to the image conditions Image with little or no movement close to a still image The image of still objects will be clea...

Page 20: ...omatic sequential 4 divisions split screen display Press the SEQUENCE button The SEQUENCE indicator flashes The 4 divisions split screens are displayed sequentially according to the 4 divisions split screen sequential mode and speed set in the MONITOR SET menu see page 32 The camera SELECT indicators 1 4 5 8 9 light sequentially according to the displayed 4 divisions split screen To cancel the seq...

Page 21: ...9 When an alarm trigger is received the display switches to a 9 divisions screen The alarm channel pictures are displayed with EA External Alarm and the camera title shown alternatively To cancel an alarm channel pictures To cancel an alarm pictures display press the corresponding SELECT button The alarm pictures display will be cancelled but not the alarm operations To cancel the alarm operations...

Page 22: ...erefore not possible When playing back a tape recorded in multi viewer mode MULTI MODE set to ON the pictures will only be played back as recorded and it will therefore not be possible to switch the display mode full screen or split screen When playing back a tape recorded in field switcher mode even if the viewing mode is set to multi viewer the display of the playback picture will be the recorde...

Page 23: ...REEZE DATA ON MENU MONITOR SET MON SEQ TIMER 1 S QUAD SEQ TIMER 1 S MON SEQ MODE MODE1 MON MASK LIVE ON MON MASK VCR ON MULTI MODE OFF DISPLAY SET LIVE CLOCK OFF TITLE ON VCR PB CLOCK OFF TITLE ON TITLE POSITION DOWN CLOCK POSITION SET PRESS NEXT EXIT Menu display NEXT NEXT CAMERA SET NO 01 TITLE 01 DAY NIGHT PROGRAM REC OFF OFF MON MASK OFF OFF SEQUENCE 1 S 1 S VIDEO LOSS ON SENSOR SET PRESS NEXT...

Page 24: ...or Press the EXIT button to exit the menu display and the selected language is set All the on screen menus and settings will be displayed in the selected language MENU LANGUAGE LANG SPRACHE ENGLISH FRANCAIS DEUTSCH HORLOGE 01 01 2000 SAM 00 00 00 PROGRAMMATEUR JOUR 00 00 00 00 HEURE ETE MODE NON SEM MOIS HEURE MAR DER DIM 03 02 00 ARR DER DIM 10 02 00 UHRZEIT 01 01 2000 SA 00 00 00 TIMER EINST TAG...

Page 25: ... To set the display mode for the clock refer to DISPLAY SET CLOCK TITLE on page 41 TIMER SET You can set a DAY and a NIGHT range for the 24 hour day period in order to set each camera mode and programmed recording accordingly 1 Set the daytime period start and end time 2 Example Day period from 7 30 AM to 7 30 PM Night period from 7 30 PM to 7 30 AM 1 Using the or button select 7 for the starting ...

Page 26: ...ST first second third fourth or last 2 Press the or button to set the WEEK TUE then press the c button Menu SUN MON TUE WED THU FRI or SAT 3 Press the or button to set the MON 05 then press the c button Menu 1 2 3 4 11 12 for January February March December 4 Press the or button to set the TIME 03 then press the l button Following the same procedure as above set when the time is changed back from ...

Page 27: ...CR that does not output a switching signal in 3H mode With a real time VCR Set the recording speed to use when an alarm trigger is received to match the alarm recording speed of the real time VCR The available speeds are 6H Default setting 18H NC F6 NC When an alarm trigger is received the recording speed is not changed and stays as set under REC SPEED F6 Use this setting when using the SW output ...

Page 28: ... or button select the desired DATA SPEED setting then press the l button 3 Using the or button select the desired ALARM SEND setting 4 Press the MENU button to go to the next menu screen or Press the EXIT button to exit the menu display SERIAL SET menu DATA SPEED Default setting 19200 bps The available settings are 2400 4800 9600 19200 bps ALARM SEND Default setting OFF ON The alarm information is...

Page 29: ... when an alarm trigger is received OFF The buzzer will not be heard DATA Default setting ON ON The alarm data is recorded OFF The alarm data is not recorded MON OUT In the MONITOR SET menu when MULTI MODE is set to ON set MONITOR OUT to FULL MULTI 9 or NC A FULL Default setting If an alarm trigger is received the picture from the camera corresponding to the alarm input will be displayed full scree...

Page 30: ...sor triggers will be considered as alarms and when received the display will switch to the selected alarm display mode and the buzzer will be heard OFF The sensor triggers are not considered as alarms AND Only when a sensor trigger and an alarm trigger are received simultaneously it will be considered as an alarm NOTE If SENSOR ALARM is set to AND a trigger to an ALARM IN terminal alone will not b...

Page 31: ... mode for that camera when an external alarm or a video sensor trigger is received VIDEO LOSS SET When the live picture signal feed is interrupted you can set the action taken frozen picture or test chart and if the video loss is recorded as alarm data Setting the Video Loss Mode 1 Press the l button to highlight the VIDEO LOSS setting 2 Using the or button select the desired VIDEO LOSS setting th...

Page 32: ...02 03 04 05 06 07 08 09 02 02 02 02 02 02 02 02 02 02 02 Alarm duration for camera 2 Camera 2 picture Camera 4 picture 02 02 02 04 04 04 01 02 04 05 06 07 08 09 01 03 04 01 02 03 04 01 02 03 04 05 06 07 08 09 02 05 02 04 06 02 07 04 08 04 09 04 02 05 02 04 06 02 07 04 08 04 09 04 Normal REC MODE MODE1 REC MODE MODE2 Alarm trigger in Alarm trigger in Alarm trigger in Alarm trigger in Alarm trigger ...

Page 33: ...yed in a 9 divisions screen see page 40 MON MASK LIVE Default setting ON ON If for certain cameras in the CAMERA SET menu the MON MASK item is set to ON the live picture from those cameras will not be visible on screen OFF The live picture from all cameras will be visible on screen regardless of the MON MASK item setting of each camera in the CAMERA SET menu MON MASK VCR Default setting ON ON If f...

Page 34: ...terruption is frozen on screen or test chart can be displayed However the frozen image and test chart settings cannot be used together D SENSOR SET Sensor areas can be set for every camera screen in live picture mode By setting certain areas that operate as video sensors priority recording of the concerned camera pictures can be done when a movement is detected within the set sensor area A Setting...

Page 35: ...med recording will be conducted according to the MODE1 or MODE2 setting entered in the VCR SET menu 7 Press the MENU button to go to the next menu screen or Press the EXIT button to exit the menu display CAMERA SET menu PROGRAM REC Default setting DAY and NIGHT to OFF ON When the time set in the TIMER SET menu is reached the pictures from this camera will be recorded in priority OFF Programmed rec...

Page 36: ...a 7 Press the MENU button to go to the next menu screen or Press the EXIT button to exit the menu display CAMERA SET menu AL DURATION Default setting DAY and NIGHT to 10 S If in the ALARM SET menu the item DURATION is set to INDIV enter the desired alarm duration for each camera The available durations are 1 2 3 4 5 10 20 in 10 seconds increments 180 CC NC OFF CC The alarm will go on as long as th...

Page 37: ... 7 Press the MENU button to go to the next menu screen or Press the EXIT button to exit the menu display CAMERA SET menu MON MASK Default setting DAY and NIGHT to OFF If in the MONITOR SET menu monitor masking is set to ON for live and or recorded monitoring set this item for each camera ON The pictures from this camera will be masked not displayed OFF The pictures from this camera will be visible...

Page 38: ...7 Press the MENU button to go to the next menu screen or Press the EXIT button to exit the menu display CAMERA SET menu SEQUENCE Default setting DAY and NIGHT to 1 S If in the MONITOR SET menu the items MON SEQ TIMER are set to INDIV enter the desired sequential display interval for each camera The available durations are 1 to 30 sec SKIP SKIP In automatic sequential display this camera will not b...

Page 39: ...creen or Press the EXIT button to exit the menu display CAMERA SET menu VIDEO LOSS Default setting ON Set the action to take when there is an interruption in the live video signal feed ON A video loss alarm trigger is sent OFF No video loss alarm trigger sent 1 2 ACTIVE REC SET EXT ALARM REC OFF SENSOR REC OFF REC MODE MODE2 VIDEO LOSS SET VIDEO LOSS INDIV DISPLAY FREEZE DATA ON MENU CAMERA SET NO...

Page 40: ... The sensor sensitivity level can only be checked for the time of the setting I e the night level setting cannot be checked during the day 5 Set the sensor response mode 1 Press the c button to highlight the MODE setting 2 Using the or button set the desired mode MODE A default setting The video sensor will send a trigger when it detects movement at the video sensor area points A MODE A AND B Set ...

Page 41: ...ber 04 2 Press the or button to change the number to the desired camera number 09 When a camera is moved to a certain position it will switch display positions with the camera that was previously displayed at that position 3 Press the MENU button to go to the next menu screen or Press the EXIT button to exit the menu display Example of switched camera display 2 2 POSITION SET MULTI 9 01 02 03 09 0...

Page 42: ...B CLOCK Default setting OFF OFF The recorded date and time are not displayed during VCR playback picture mode ON The recorded date and time are displayed during VCR playback picture mode VCR PB TITLE Default setting ON OFF The recorded camera title is not displayed during VCR playback picture mode ON The recorded camera title is displayed during VCR playback picture mode Setting the clock display ...

Page 43: ...he EXIT button to exit the menu display The codes in the ITEM column indicate the type of alarm data E External alarm trigger see page 43 S Video sensor trigger see page 39 44 V Video loss see page 43 NOTE When the number of recorded alarm data entries reaches 100 the oldest ones are erased as new ones are recorded The illustrated alarm data entries screens are a sample of alarm inputs ALARM DATA ...

Page 44: ... the ALARM SET menu During normal monitoring operations the camera select indicator lights according to the displayed camera If there is an alarm trigger for another camera the indicator will flash VIDEO LOSS ALARM If there is an interruption of the video signal the buzzer is heard and the image just previous to the interruption is frozen on screen or test chart are displayed and VIDEO LOSS will f...

Page 45: ...ode can be set in the ACTIVE REC SET menu see page 30 Resetting the Alarm For an alarm in full screen display mode press the corresponding SELECT button during the alarm operation For an alarm in multi display screen mode press the corresponding SELECT button to switch to full screen display mode then press the same SELECT button one more time RECORDED PICTURES MODE ALARM In VCR playback mode only...

Page 46: ...to finish This unit will receive the commands and will reply to each command by ACK 0A Refer to COMMAND TABLE 4 on page 49 RS 485 RJ 11 connector layout Pin No A terminal signal B terminal signal 1 Not used Not used 2 Not used Not used 3 A signal B signal 4 B signal A signal 5 Not used Not used 6 Not used Not used A Non inverting driver output receiver input B Inverting driver output receiver inpu...

Page 47: ...erminator using DIP switch 10 COMMANDS COMMANDS AVAILABLE FROM THE COMPUTER 1 9 90 98 To select the picture from a camera to be displayed full screen on monitor MULTI 82 To display a 9 divisions split screen on monitor QUAD 83 To display a 4 divisions split screen on monitor SEQUENCE 87 To switch the display mode from full screen to sequential display on monitor ZOOM 85 To zoom in the picture on m...

Page 48: ... display 0000 Full screen 1000 9 divisions split screen Plus display 0000 Channel 1 0001 Channel 2 0010 Channel 3 0011 Channel 4 0100 Channel 5 0101 Channel 6 0110 Channel 7 0111 Channel 8 1000 Channel 9 Menu display 0001 LANGUAGE LANG SPRACHE menu 0010 CLOCK SET menu 1000 VCR SET menu 0100 ALARM SET menu 0101 ACTIVE REC SET menu 0110 MONITOR SET menu 0011 CAMERA SET menu 1110 POSITION SET menu 01...

Page 49: ... 3 VIDEO LOSS 4 3 2 VIDEO LOSS 3 2 1 VIDEO LOSS 2 1 0 VIDEO LOSS 1 0 VIDEO LOSS 9 COMMANDS AVAILABLE FROM THE MULTIPLEXER ACK 0A Response when this unit receives a command NAK 0B Response if this unit did not receive the command ALARM BF When there is an alarm this command is sent as header Then the alarm information is sent in a 1 byte transmission see Table 3 ALARM information Table 3 Bit Bit st...

Page 50: ...2 2 VERSION MULTI FULL 3 3 3 QUAD FULL 4 4 4 1 O MENU FULL 5 5 5 NEXT ZOOM FULL 6 6 6 EXIT STILL FULL 7 7 7 SEQ FULL 8 8 8 FULL 9 9 9 SECURITY LOCK ON A ACK SECURITY LOCK OFF B NAK C GROUP SET D GROUP CHECK E GROUP CLEAR F A B C D E F 0 CLK ADJ 1 MENU RESET 2 3 4 5 ALARM STATUS SENSE 6 ON 7 STATUS SENSE OFF 8 9 A B C D RS485 TRANSMISSION START E RS485 RCV CHECK F ALARM Only RS485 Only RS232C L8FN5...

Page 51: ... manufacturer specifications RS485 control terminal RJ 11 type 2 terminals A B Push lock type 3 terminals A B C Ground RS 232C terminal 9 pin D SUB Full screen sequence timing Available in full screen mode with interval selectable from 1 30 sec Monitor on screen display Title up to 10 characters date time selectable Menu settings 10 menus Language Clock VCR Alarm Active REC Monitor Camera Position...

Page 52: ...SANYO Electric Co Ltd 1AC6P1P2017 L8FN5 XE UK 0100KP NI01 Printed in Japan L8FN5 XE MPX MS92P GB 2000 8 31 ...

Reviews: