page 1
Installation and Battery Change Instructions
Quick Mount Keypad
for use with S&G 6120, 6123, Titan 2006 and
Spartan
™
1006 PivotBolt Safe Locks
Copyright
©
2014, Sargent & Greenleaf, Inc.
Document 630-876
Revised 6/5/2014
M
ounting
C
onsiderations
• Sargent & Greenleaf Quick Mount Keypads are designed with the same mounting screw locations as most other S&G
locks, both mechanical and electronic, to simplify retrofit.
• Modifications to the keypad are not recommended and will void the product warranty.
• The Quick Mount Keypad will accommodate one 9-volt battery. S&G recommends fresh Duracell
®
brand batteries.
Do not use old or partially drained batteries.
Sargent & Greenleaf, Inc.
PO Box 930
Nicholasville, KY 40340-0930
Phone: (800)-826-7652 Fax: (800)-634-4843
Phone: (859)-885-9411 Fax: (859)-887-2057
Sargent & Greenleaf S.A.
9, Chemin du Croset
1024 Ecublens, Switzerland
Phone: +41-21 694 34 00
Fax: +41-21 694 34 09
Attaching Screws:
Use only the screws provided with the keypad. Mounting screws will be either 8-32 or M4, depending on the applica-
tion. They must engage the mounting surface (safe door) by at least four full threads. Do not use thread sealing compounds as these may
weaken the keypad base material.
Recommended Attaching Screw Torque:
No more than 15 inch-pounds (1.695 Nm) for the keypad attaching screws.
Minimum Lock Cable (Spindle) Hole Diameter:
0.312
"
(7,9 mm)
Maximum Lock Cable (Spindle) Hole Diameter:
0.406
"
(10,3 mm)
Code Restrictions:
Personal data that can be related to a code holder, such as a birth date, street number, or phone number, should not
be used in creating a lock code. Avoid codes that can be easily guessed.
Note:
Every installation of this product must comply with these requirements and those in the product installation instructions to qualify
for the manufacturer’s warranty and to comply with EN1300 requirements.
LOCK CABLE
RECEPTACLE
SPACE FOR
EXCESS CABLE
MOUNTING STUD
OPENINGS
BACK OF KEYPAD
B
efore
Y
ou
I
nstall
Your S&G electronic safe lock should be installed inside the safe door first, following the instructions with which it is
packaged. The lock cable should be extending through the door’s spindle hole to the outside of the safe.
FRONT OF KEYPAD
LIGHT BUTTON
If the version of keypad you are installing includes the light feature, after
battery installation, press this button to illuminate the keypad for ten seconds.