background image

 

®

 

 

AQUA RING S 

CEILING MOUNT 
DIGITAL PASSIVE INFRARED DETECTOR 

 
 
 

aquaring_s_

en 07/11

 

The microprocessor-based, fully digital AQUA RING S detector for ceiling mount 
installation is characterized by high sensitivity and interference resistance. A dual 
pyroelectric sensor is used in the detector. The detector can be supplied with AC or 
DC 24 V voltage. 
The detector is provided with a 

prealarm feature

. Prealarm is signaled by a short 

flash of the LED after changes which do not meet the alarm criteria have been 
detected within the coverage area. The prealarm sensitivity depends on what 
sensitivity is set on the detector pins. Frequently occurring prealarms may cause an 
alarm. 
The detector requires to warm up for the first 30 seconds after applying power. Warm-
up is indicated by a rapid LED blinking.  
 

 

Fig.1. View of detector electronics board. 

 
Explanations to Fig. 1: 
1 – terminals: 

NC

 – 

relay 

(NC) 

TMP

 – tamper contact 

Summary of Contents for AQUA RING S

Page 1: ...detector is provided with a prealarm feature Prealarm is signaled by a short flash of the LED after changes which do not meet the alarm criteria have been detected within the coverage area The prealarm sensitivity depends on what sensitivity is set on the detector pins Frequently occurring prealarms may cause an alarm The detector requires to warm up for the first 30 seconds after applying power W...

Page 2: ...F enabling disabling the LED indicator The LED indicator is enabled when the pins are shorted Fig 2 Setting the detector sensitivity A low sensitivity B and C medium sensitivity D high sensitivity pins shorted pins open 1 Installation The detector is designed for indoor installation Fig 3 Objects that should not be located in the detector coverage area heat sources air conditioning outlets moving ...

Page 3: ...ins are shorted 2 When the detector is ready to work the LED will stop blinking carry out the detector range test i e check that movement within the supervised area will activate the alarm relay and lighting of the LED 3 If necessary change the detector sensitivity pins PIR SENS 3 Specifications Supply voltage 24 V AC DC 15 Max current consumption 10 27 mA for 24 V AC 14 mA for 24 V DC Relay conta...

Page 4: ... x 29 mm Recommended installation height from 2 2 m to 4 5 m Weight 64 g The declaration of conformity may be consulted at www satel eu ce SATEL sp z o o ul Schuberta 79 80 172 Gdańsk POLAND tel 48 58 320 94 00 info satel pl www satel eu ...

Reviews: