The INT-SK-GR partition keypad is designed for work in conjunction with INTEGRA and  
CA-64 alarm control panels. It is used to control the arming mode in one partition, to perform 
a function of monitoring access and controlling operation of the electromagnetic door locks, 
as well as monitoring closure of those doors. The keypad makes it possible to change the 
user code and call the functions controlling the external devices. 
This manual applies to the partition keypad with firmware version 1.10. 

1.  Description of partition keypad 

 

Figure 1. Partition keypad. 

 
The partition keypad has 12 keys with permanent or temporary (automatically activated) 
mode backlight and LED indicators. 

 

ALARM

 (red color) - steady light indicates an alarm in the keypad controlled partition, 

while blinking indicates that an alarm was triggered in the partition. 

 

ARMED

 (green color) - steady light indicates that the partition to which the keypad is 

assigned has been armed. Blinking indicates countdown of the exit delay. 

 

TROUBLE

 (yellow color) – blinking indicates that a technical problem has occurred. The 

signaling applies to troubles from the entire alarm system, not only from the keypad 
controlled partition. The type of trouble can be checked on the LCD keypad. Arming 
the keypad controlled partition will disable the trouble signaling. Disarming the 
partition will restore the trouble signaling. 

Alternative blinking of all the LEDs (from top to bottom) indicates lack of communication 
between the keypad and the control panel. This situation may take place when the STARTER 
program is running in the control panel, or when the cable connecting the keypad and the 
control panel is damaged. 

Note:

  All LEDs may be OFF in the arming mode, depending on the control panel settings. 

Summary of Contents for INT-SK-GR

Page 1: ...lled partition while blinking indicates that an alarm was triggered in the partition ARMED green color steady light indicates that the partition to which the keypad is assigned has been armed Blinking...

Page 2: ...d COM common ground 12V power supply input CLK DTA expander bus 3 Installation and connection of the module The partition keypad is designed for indoor installation It may be mounted either directly t...

Page 3: ...n be used for this purpose Details regarding the cable connections are described in the installer s manual for the alarm control panel 7 Connect the wires of the door state control sensor to the IN an...

Page 4: ...ns Figure 4 DLOADX program window with partition keypad options Name the option to give an individual 16 character name to the module This option can be accessed in the LCD keypad as follows Service m...

Page 5: ...or reconnection of the IN input to common ground but not longer than for the relay ON time Relay ON time the time period during which the relay is active Duration of the relay ON time can be from 1 to...

Page 6: ...acoustic alarm signaling in the given partition until the alarm is cleared Signaling entry delay acoustic signaling of the countdown of entry delay time Signaling exit delay acoustic signaling of the...

Page 7: ...not cleared tamper alarms This prevents multiple recording of the same events in the control panel memory The option allows this feature to be disabled 6 Technical data Nominal supply voltage 15 12V D...

Page 8: ...est EC declarations of conformity and certificates are available for downloading on the website www satel pl SATEL sp z o o ul Schuberta 79 80 172 Gda sk POLAND tel 48 58 320 94 00 info satel pl www s...

Reviews: