background image

 

‐ 

1

 ‐ 

Key

fob

 

Remote

 

Control

 

User

 

Manual

 

 

z

 

Description

 

Key

fob

 

Remote

 

Control

 

with

 

4

 

keys

 

is

 

a

 

Z

Wave

 

standard

 

reporting

 

portable

 

controller

 

(RPC).

 

It

 

supports

 

multiple

 

key

 

press

 

action

 

trigger

 

central

 

scenes

 

notification

 

and/or

 

controls

 

max

 

8

 

devices

 

in

 

group

 

turn

 

on,

 

off,

 

stop.

 

A

 

special

 

"SOS"

 

key

 

designs

 

for

 

emergency

 

notification.

 

Further

 

more,

 

it

 

can

 

act

 

as

 

primary

 

controller

 

to

 

add

 

and

 

control

 

Z

Wave

 

device

 

as

 

standalone

 

application.

 

The

 

product

 

supports

 

acting

 

as

 

Z

Wave

 

primary

 

controller

 

to

 

add

 

(inclusion),

 

remove

 

(exclusion)

 

device

 

stand

 

alone,

 

meanwhile

 

it

 

can

 

associated

 

device

 

to

 

control

 

groups

 

while

 

the

 

device

 

was

 

added,

 

supports

 

triggers

 

control

 

associated

 

device

 

in

 

groups.

 

Also,

 

It

 

supports

 

learn

 

mode

 

for

 

added

 

by

 

other

 

master

 

controller,

 

supports

 

trigger

 

central

 

scene

 

command

 

to

 

master

 

controller,

 

and

 

it

 

can

 

associated

 

control

 

devices

 

by

 

key

fob

 

local

 

operation

 

or

 

master

 

controller

 

association

 

set

 

configuration.

   

The

 

product

 

is

 

Z

Wave

 

wireless

 

accessible

 

and

 

it

 

can

 

quickly,

 

easily

 

included

 

and

 

operated

 

in

 

any

 

Z

Wave

 

network

 

with

 

other

 

Z

Wave

 

certified

 

devices

 

from

 

any

 

other

 

manufacturers.

 

All

 

non

battery

 

operated

 

nodes

 

within

 

the

 

network

 

will

 

act

 

as

 

repeaters

 

regardless

 

of

 

vendor

 

to

 

increase

 

reliability

 

of

 

the

 

network.

 

 

 

 

z

 

Button

 

define

 

Icon

 

 

 

 

 

Key

 

name

 

Off

 

On

 

Notification

 

Stop

 

Scene

 

key

 

number

 

Key1

 

Key2

 

Key3

 

Key4

 

 

 

z

 

Battery

 

replacement

 

Remove

 

the

 

battery

 

separator

 

before

 

use

 

to

 

work

 

(as

 

shown

 

on

 

the

 

right).

 

The

 

product

 

adapts

 

CR2032

 

battery.

 

Low

 

battery

 

level

 

was

 

warning

 

while

 

LED

 

blink,

 

please

 

replace

 

new

 

battery

 

as

 

soon

 

as

 

possible.

 

Open

 

the

 

bottom

 

cover

 

with

 

a

 

small

 

screw

 

at

 

the

 

plastic

 

separator

 

gap;

 

then

 

take

 

out

 

the

 

PCBA

 

to

 

replace

 

the

 

battery.

 

Please

 

be

 

noted,

 

polarity

 

of

 

battery

 

install

 

and

 

use

 

the

 

same

 

type

 

of

 

battery

 

to

 

make

 

sure

 

battery

 

using

 

life.

 

Summary of Contents for Key-fob

Page 1: ...o master controller and it can associated control devices by key fob local operation or master controller association set configuration The product is Z Wave wireless accessible and it can quickly easily included and operated in any Z Wave network with other Z Wave certified devices from any other manufacturers All non battery operated nodes within the network will act as repeaters regardless of v...

Page 2: ...iated from GUI of the master controller Secure vs no Secure add to Z Wave Network The production is a security enabled Z wave Plus production implements Z Wave Application Security Layer in accordance with Z Wave protocol This device must be used in conjunction with a Security Enabled Z Wave Controller in order to fully implemented secure functions Even though the functionality and support command...

Page 3: ... Function Description LED indicator Press and hold for 2 sec Illumine 1 Reset Factory Default Press and hold for 10 sec Blink off 0 5sec interval 2 second while hold until flash on 3 times Press and hold for 2 sec Illumine 2 Wakeup key fob manually and send battery report to lifeline group 1 Press 3 times in 2 sec Flash on fast 3 times then keep in wakeup for 30 second w o initial wakeup parameter...

Page 4: ...rotected Press or hold any key Blink on 3 times 0 5 second on 0 5 second off Note Item 1 2 15 16 is available while key fob in Idle state item 3 4 is available as key fob is primary or installer controller Item 5 is available as key fob is primary controller only item 6 is available as key fob hasn t add any node item 9 11 is available in anytime item 7 8 12 14 is available as key fob was added in...

Page 5: ...ce procedure Remove Z Wave Device from key fob 1 Press and hold both and key together for 2 seconds until LED indicator light on release all key 2 Press and hold key for 2 seconds until LED indicator flash quickly 1 second on 1 second off key fob starts remove device processing 3 Refer to device manual trigger the device which is going to included start network add remove mode 4 If key fob detects...

Page 6: ... if there not any controller was detected Note Key fob s learn mode is only available as it has not added any device before or has included in master controller already Key fob always ignores Basic Set Get command requires from other controller Note Press and hold on key for 2 seconds after step 3 would terminal procedure if Z Wave adding processing has not started Remove key fob from other Z Wave...

Page 7: ...vice from group 2 4 together and LED indicator light on for 3 seconds after delete association successful If key fob has not detects any device in 60 seconds exit delete associated device process and LED indicator goes off Note Key fob s delete associated locally function is only available as it was included in other master controller Key fob always deletes the associated device with endpoint toge...

Page 8: ...C_CONTROLLER Specific Device Type SPECIFIC_TYPE_PORTABLE_REMOTE_CONTROLLER Support Command Class COMMAND_CLASS_ZWAVEPLUS_INFO COMMAND_CLASS_VERSION COMMAND_CLASS_WAKE_UP COMMAND_CLASS_SECURITY COMMAND_CLASS_MANUFACTURER_SPECIFIC COMMAND_CLASS_POWERLEVEL COMMAND_CLASS_DEVICE_RESET_LOCALLY COMMAND_CLASS_ASSOCIATION COMMAND_CLASS_ASSOCIATION_GRP_INFO COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION COMMAND_CL...

Reviews: