Page 1: ...NU eNodTouchM E 0815_196774 B SCAIME SAS Technosite Altéa BP501 74105 ANNEMASSE Cedex Tél 33 0 4 50 87 78 64 www scaime com eNodTouch M Touch screen for multiple eNod4 controllers User Manual ...

Page 2: ... 3 2 1 Increase eNod number 17 3 2 2 Select an eNod 19 3 2 3 Communication error and disconnection 20 3 3 Main screen 21 3 3 1 Transmitter mode eNod4 T 21 3 3 2 Checkweigher mode eNod4 C 22 3 3 3 Dosing mode eNod4 D 23 3 3 4 Keyboard functions 24 3 4 Result displaying and storage eNod4 C eNod4 D 25 3 5 Main setup menu 27 3 5 1 eNodTouch setup 28 3 5 2 Starting Parameters 28 3 5 3 Calibration setup...

Page 3: ...0Ω Dimension W97 6 x H79 5 x D31 5 mm Weight 0 36 kg approx Surrounding air temperature 0 to 50 C Ambient humidity 85 RH Wet bulb temperature 39 or less no condensation Dust 0 1 mg m or less non conductive levels Storage temperature 20 to 60 C Structure IP65 on the front panel when properly installed in an enclosure Cooling method Natural air circulation Serial Interface COM1 RS 422 485 Asynchrono...

Page 4: ...4 User manual SCAIME NU eNodTouchM E 0815_196774 B A USB Interface Type A USB1 B Serial Interface COM1 C Ethernet Port D Supply connector E USB Interface mini B USB2 ...

Page 5: ...5 User manual SCAIME NU eNodTouchM E 0815_196774 B 1 2 Dimensions 1 2 1 eNodTouch M ...

Page 6: ...6 User manual SCAIME NU eNodTouchM E 0815_196774 B 1 2 2 eNodTouch ML ...

Page 7: ...res and other equipment Be sure that the surrounding air temperature and the ambient humidity are within their designated ranges Surrounding air temperature 0 to 50 C Ambient humidity 85 RH Wet bulb temperature 39 C max When installing eNodTouch on the panel of a cabinet or enclosure Surrounding air temperature indicates both the panel face and cabinet or enclosure s internal temperature The panel...

Page 8: ...anel 1 Material of the panel Steel 2 Material of the panel Glass fiber reinforced Installation procedure Step Action 1 Place the unit on a clean and level surface with the display panel facing downward 2 Cut a panel with the specified thickness in function of the material 3 Create the correct sized hole with a diameter of 22 5mm tol 0 30 on the panel 4 Insert the display module following the illus...

Page 9: ...l it locks into place IMPORTANT Install the rear module in the orientation shown in the illustration If either unit is installed incorrectly the connector may be damaged 6 To remove the rear module push the yellow button to unlock it then pull the rear module out following the illustration ...

Page 10: ...SCAIME NU eNodTouchM E 0815_196774 B 1 4 Electrical powering Supplying a power voltage other than that specified will damage the power source and the unit When the FG terminal is connected be sure the wire is grounded ...

Page 11: ...9 connector Please follow the below cable recommendation or use a SCAIME Cable ref 632153 Contact your local sales representative for more information Important You may need to add a terminating resistor 120 Ohm if the distance between eNod4Touch and eNod4 is important If distance is short 1m do not add resistor ...

Page 12: ...Entering Offline mode At Power ON Touch the upper right corner or upper left corner within 40 pixels of the edges of the panel for at least 3 seconds soon after the startup screen is displayed When Operating Touch the upper right then bottom left corners or the upper left and bottom right corners of the panel within a 40 pixel area in 0 5 seconds When the system menu is displayed touch the Offline...

Page 13: ...e from 1 to 255 minutes after which the screen is cleared 1 Change to Screen N in Standby Mode Related to Screen Change Standby mode 1 Operation Settings Touch Panel Detection To detect touch on touching ON or Releasing OFF the panel ON Touch Buzzer Sound Enable Disable the in built Buzzer sound upon a touch Disable Display settings Show Brightness contrast control bar Specify whether to display o...

Page 14: ...ait to send ms 10 Device Device Name eNod4_1 eNod4_6 Slave Address Decimal eNod4 slave address Should be set according to eNod4 communication settings 1 6 Max Query Read Input Reg 30 Max Query Read Holding Reg 30 Max Query Write Holding Reg 30 Note Never change the parameters in grey 2 2 4 Password menu Menu Input Parameter Description Default System Password System Password The password setting i...

Page 15: ...unction Confirms whether the liquid crystal display LCD displays correctly Check Touch Panel Touch panel check Checks that the touched area lights up correctly Calibration Correct an analog touch panel Continue touching until the crosshatch moves or disappears Check com Check the send and receive lines of network communication ...

Page 16: ...f the communication is established between eNodTouch and eNod4 communication or an error screen if eNodTouch does not manage to connect to the eNod If there is no eNod4 connected or if the display unit cannot communicate with eNod4 device a communication error screen appears In this case check the wiring between eNodTouch and eNod4 1 4 and check that the communication parameters of eNodTouch and e...

Page 17: ...utton Main Menu eNodTouch Menu Starting Parameters By default the eNod number is 1 eNodTouch starts on the main screen of the first eNod Increase eNod number if needed The display module can start on the main screen of any eNod or on the multi eNod screen by disabling Starting eNod function If starting eNod is disconnected or have communication problems the multi eNod screen appears When settings ...

Page 18: ...ME NU eNodTouchM E 0815_196774 B Multi eNod 2 eNod Multi eNod 3 eNod Multi eNod 4 eNod Multi eNod 5 eNod Multi eNod 6 eNod Channel name Weight value Unit Gross Net Indicator eNod4_1 eNod4_3 eNod4_5 eNod4_2 eNod4_4 eNod4_6 ...

Page 19: ... B 3 2 2 Select an eNod To display the main screen of an eNod touch its display area Example for eNod n 1 Touch its display area Main screen of eNod To return to multi eNod screen touch the channel red button Touch of channel button Multi eNod screen ...

Page 20: ...d4 the button enters in the state eNod disconnected the data display resumes Identify the communication problem in the following list wiring problem 1 4 communication parameters misconfigured on eNodTouch or eNod4 2 2 3 When you found out the issue touch the eNod disconnected button to re establish the communication The display module tries to recover the communication with eNod4 during 1 second t...

Page 21: ...from the main keyboard to the 2nd keyboard touch To switch from the main screen to the multi eNod screen touch Bargraph Gross Net indicator Stability indicator Main keyboard Inputs Outputs status Measure near zero indicator Weight display area Channel selection button Gross weight Keyboard masked 2 nd keyboard ...

Page 22: ...mode eNod4 C To switch from the main keyboard to the 2nd keyboard touch To enter the checkweigher quick access menu touch Access to result screen Last Checkweigher Result 2nd keyboard Checkweigher Status Bar Result recorder status Status bar Main keyboard Transmitter mode ...

Page 23: ...o enter the dosing quick access menu touch Dosing faults F Err flow rate failure OUT Dosing result upper to max tolerance value OUT Dosing result lower to min tolerance value STA Err Error in launch cycle 2nd keyboard Access to result screen Last dosing result Status bar Dosing Status bar Dosing cycle status Dosing error Transmitter mode ...

Page 24: ...asurement averaging without stability condition eNod4 D SUSPEND DOSING Visible only if dosing suspension setting is enabled Allow to restart a suspended dosing cycle without checking starting conditions STOP CYCLE Stop the dosing cycle the dosing counter is not incremented MANUAL EMPTYING Visible only in filling mode with Manual Emptying mode Allows to activate the emptying logical output during t...

Page 25: ...average From this screen it is also possible to record up to 1000 results with the possibility to transfer these stored results on USB key in CSV format Recorder stopped Recorder running Important note about the recorder When the recorder is running only the main screen and the result screen are accessible to enable this recording As a consequence some touch keys giving access to other screens are...

Page 26: ...ART recorder STOP recorder Access to a screen displaying the table of stored results Access to a screen allowing the Transfer of stored results to an USB key under CSV file Indicators Indicates the recorder running Indicates the maximum recorder capacity 1000 results is reached ...

Page 27: ...For more information about parameters consult eNod4 software manuals Setup menu access can be secured by password see 3 5 1 In that case the following screen is displayed After entering a valid password or OLEG if you ve forgot your password the following menu will be displayed eNod4 T Transmitter mode eNod4 C Checkweigher mode eNod4 D Dosing mode ...

Page 28: ...een Password Yes No Enable Disable access protection to setup menu 4 Char By default OLEG is a master password always valid 3 5 2 Starting Parameters Parameter Possible value Description eNod number 1 6 Number of eNod4 supported Starting eNod Yes No Enable Disable the function to start on main screen of a specific eNod 1 eNod Number Number of starting eNod4 If there is only one eNod4 supported thi...

Page 29: ...Possible Value Description Calibration Parameters Range 0 10 000 000 Maximum weighing capacity Division 1 2 5 10 20 50 Difference between two consecutive indicated values Decimals 0 7 Position of decimal point Unit 4 visible char Weight measurement unit g kg t lb displayed on main screen ...

Page 30: ... Number of loads 1 2 3 Number of calibration loads used during the physical calibration load 1 2 3 1 1 000 000 Weight values corresponding to each calibration segment Zero Calibration Allows acquiring stable measurement with no load on the scale to set the calibration Zero ...

Page 31: ...tory calibration to the user calibration S mV V 0 6 00000 Load cell sensitivity in mV V at maximum capacity Span Calibration correction Span cor 0 9 1 100000 Allows to adjust initial calibration Calibration g 0 9 805470 Allows compensating the gravity difference between calibration place and using place Use g 0 9 805470 ...

Page 32: ...32 User manual SCAIME NU eNodTouchM E 0815_196774 B 3 5 4 I O Setup eNod4 T eNod4 D eNod4 C ...

Page 33: ...tion Debounced time 0 65535 Minimum required time of the logical inputs before their activation Output 1 4 Parameters Function Function assigned to the related output None Thresholds Stability Coarse feed High feed fine feed Cycle ongoing result available Out of tolerance Dosing fault Input copy Remote control Out of tolerance Out of tolerance Logic Positive Negative Defines idle output state Mode...

Page 34: ...d values of the concerned outputs Remote Control Allows fixing the level On Off of the concerned outputs Outputs 1 4 timings In Checkweigher allows modifying timings on outputs with functions Remote control activation time Result within tolerances and Result out of tolerances activation time and delay ...

Page 35: ...etup Parameter Possible Value Description Metrology Parameters Stability criterion None 0 25 0 5 1 2d Defines a stability interval related to scale interval Zero at Startup Yes No Enable the Automatic Zeroing at power on Zero Tracking Yes No Enable the Zero tracking function ...

Page 36: ...rver on this subnet Swap data Swap data bytes in Modbus TCP registers 16 bits words Name Profinet station name up to 10 char with Option Use rotary switch in Name else 15 lower case figures dots and dashes only Option Use rotary switch in Name Allows on Save automatic appending of hexadecimal representation of rotary switches in the Name Byte order Byte order in Profinet exchanges Little Endian Bi...

Page 37: ... frequency is adjustable from 6 25 to 1600 Hz Bessel low pass filter parameters Filter Order 0 2 3 4 For the suppression of periodic vibrations a Bessel low pass digital filter can be applied as an output of the A D converter Minimum cut off frequency value depend on the A D converter rate 0 10 Hz for 6 25 meas s 4 Hz for 400 meas s Cut Off Frequency 0 1 to 200Hz Notch Filter parameters High Low F...

Page 38: ...esetting eNod4 or making eNod4 come back to factory settings Channel name Name or rename the channel with a maximum of 4 characters 3 5 6 Function mode setup eNod4 C eNod4 D According to the eNod4 model the following screen is displayed to select the functioning mode eNod4 C eNod4 D ...

Page 39: ...rameter Possible Value Description Dynamic Zero parameters Dyn Zero time 0 65535 ms The Dynamic zero function is the acquisition of a zero without stability criterion obtained by averaging measurements during the specified time Automatic Dyn Zero Yes No Automatic zero correction allows to dynamically track the Zero evolution When enabled an average Zero value is continuously calculated using the D...

Page 40: ...rigger level when the load cell signal reaches the specified value Result calculation settings Stabilization time 0 65535 ms During this time measurements are not taken into account for result calculation Measuring time 0 65535 ms During that time the signal is taken in account to calculate the result Result correction 0 9 1 100000 Eventually used to adjust the checkweigher result ...

Page 41: ...00 The value to reach at the end of the checkweigher cycle Tolerance Define the acceptable lower range for checkweigher results Tolerance Define the acceptable upper range for checkweigher results Stats only on in Tol res Option for only use checkweigher results within tolerances to calculate statistics results average running total results sum standard deviation ...

Page 42: ... Detailed explanations on Dosing functioning and parameters could be found into eNod4 D manuals The following setup menu allows modifying the parameters related to dosing Filling or Unloading mode 3 7 1 Dosing Cycle Setup Parameter Possible Value Description Dosing cycle parameters ...

Page 43: ...000 000 The emptying output is disabled if the net value becomes inferior to this level and if the emptying holding time has elapsed Reloading Min Level 0 1 000 000 Output assigned to the reloading function is activated if the gross measurement is less than reloading Min Level until the measurement become greater than reloading max Level Reloading Max Level 0 1 000 000 Page 3 3 Dynamic mode Yes No...

Page 44: ...erification at the start of cycle Min empty weight Gross measurement Max empty weight If Min empty weight Max empty weight 0 No verification Max empty weight Automatic start Yes No Filling cycle starts automatically when the gross weight is between the Min empty weight and Max empty weight Unloading mode Residual weight 0 1 000 000 eNod4 D refuse start cycle and reports a dosing error if gross mea...

Page 45: ...ptying Reloading A dosing cycle is considered complete after this delay Page 2 3 HF CF FF masking time 0 65535 ms During this delay flow rate and level control are disabled to mask the dynamic effects caused by the related feed activation Page 3 3 Emptying Reloading Holding time 0 65535 ms Defines how long the emptying Reloading output remains active after the ending of Emptying or reloading condi...

Page 46: ...be automatically corrected Min Max In Flight level 32768 Min In flight Level In flight Level max In flight Level If this condition is not satisfied In flight is not changed If these levels are zero there is no control of limits But regardless of these limitations the value calculated automatically is limited to FF level Page 2 2 Correction 0 100 If Automatic correction enabled the correction formu...

Page 47: ...the net measurement has been change of less than the minimal weight variation then the cycle is stopped and a flow rate error is detected Time Interval 0 65535 ms 3 7 6 Dosing Tolerance control Parameter Possible Value Description Tolerance control parameters Tolerance and 0 65565 Define the acceptable range for dosing results An output assigned to the out of tolerances is set active if the dosing...

Page 48: ...et weight 0 1 000 000 Target weight represents the value to reach at the end of the dosing process CF to FF Level 0 1 000 000 Used in sequences using at least 2 or 3 feeds Defines the transition threshold relative to the target weight between the Coarse feed and Fine Feed phase FF to CF Level Used in sequences where FF comes before a CF phase Defines the transition threshold relative to the target...

Page 49: ...eNodTouchM E 0815_196774 B 3 9 Configuration of Quick Access menu Allows selecting the dosing data accessible by the touch from the main screen 3 3 3 and 3 3 4 With the example shown above the touch will open the following menu ...