Instruction Manual Power Supply Unit CSV 300

Instruction manual

Power supply unit CSV 300

CSV 300
CSV 300 2B10
CSV 300 2B13
CSV 300-3

Table of contents

1

Introduction  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

2

Safety information  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

3

Description and appropriate use  . . . . . . . . . . . . . . . . . . . . . . . . . . 3

4

Electrical data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

5

Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

6

Maintenance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

7

Shutting down  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

8

Technical faults, possible causes and remedies . . . . . . . . . . . . . . 6

9

Customer service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

10

EG Conformity Declaration

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

11

Block diagram - for specialist workshop only . . . . . . . . . . . . . . . . . 8

12

Fault report. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

Summary of Contents for CSV 300 2B10

Page 1: ...SV 300 Instruction manual Power supply unit CSV 300 CSV 300 CSV 300 2B10 CSV 300 2B13 CSV 300 3 Table of contents 1 Introduction 2 2 Safety information 2 3 Description and appropriate use 3 4 Electrical data 5 5 Operation 5 6 Maintenance 5 7 Shutting down 6 8 Technical faults possible causes and remedies 6 9 Customer service 7 10 EG Conformity Declaration 7 11 Block diagram for specialist workshop...

Page 2: ...he power supply unit must be dealt with immediately by qualified personnel Failure to comply with this sign may lead to the endangerment of per sons Failure to comply with this sign may damage the device or the connected consumers This sign indicates recommendations or special features The electrical system of the motorhome or the caravan has to meet current DIN VDE and ISO regulations Manipulatio...

Page 3: ... or repair fuses Danger of burning Blown fuses must only be changed on a zero cur rent power supply unit Only use original fuses rated as specified in the instruction manual Danger of burning During operation the power supply unit gets hot Do not touch There must be no cables laid underneath the power supply unit due to the development of heat To avoid voltage peaks during warm up do not connect t...

Page 4: ...t tery of their own and can therefore not be used for charging batteries Fig 1 Power supply unit CSV 300 CSV 300 2B10 CSV 300 2B13 and CSV 300 3 1 Negative 12 V outputs circuits 1 to 5 2 12 V outputs circuits 1 to 5 3 12 V Car battery tow bar 4 12 V Car battery tow bar 5 Flat vehicle fuses 6 Fuse puller 7 Spaces for circuit breakers 3 4 7 9 7 0LQXV UHLV UHLV ...

Page 5: ...d next to the vehicle flat fuses Change over relay A change over relay is installed in the power supply unit The change over relay interrupts the connection to the starter battery when the caravan has a 230 V mains power supply If there is no 230 V mains power supply the 12 V consumers are powered by the starter battery of the towing vehicle CSV 300 CSV 300 2B10 CSV 300 2B13 Circuits 1 to 5 are po...

Page 6: ... a fault using the following tables please contact our customer service address If this is not possible e g if you are abroad you can have the power supply unit repaired at a specialist workshop Inexpert repairs invalidate the guarantee for the power supply unit and Schaudt GmbH takes no liability for any resulting damage Fault Possible cause Remedy All connected consumers are not powered No mains...

Page 7: ...product service life is over dispose of the device in accordance with the applicable regulations 10 EG Conformity Declaration Schaudt GmbH hereby confirms that the CSV 400 1 A caravan power supply design complies with the relevant regulations This declaration is based on Type approval of Kraftfahrt Bundesamt German Federal Motor Transport Authority Type approval no e1 72 245 2006 28 5758 00 EC app...

Page 8: ...ht supplied only by mains A24 A23 Circuit 5 awning light supllied by vehicle battery too 3 Protective earth conductor yellow green 4 Neutral conductor blue 5 External conductor brown 6 230 V mains output 8 outputs free 3 x plug distributor 6 3 x 0 8 10 x 7 Vehicle battery tow bar ext fuse max 15 A 8 Vehicle battery tow bar ext fuse max 15 A 9 12 V output circuit 1 10 12 V output circuit 2 11 12 V ...

Page 9: ...defective device together with the completed fault report There is the following defect please tick Other remarks Device type Type no please delete whatever does not apply CSV 300 905 030 CSV 300 2B10 905 031 CSV 300 2B13 905 032 CSV 300 3 905 036 The following electrical con sumers do not work Constant fault Temporary fault loose con tact ...

Page 10: ...10 Situation 25 11 2009 805 031 BA EN Instruction Manual Power Supply Unit CSV 300 ...