background image

series

venting systems
for high efficiency 
appliances

Summary of Contents for eVent Series

Page 1: ...series venting systems for high efficiency appliances ...

Page 2: ... offered In addition to the standard components virtually any conceivable fitting is available as a special order item MATERIAL AVAILABLE eVent is available in a variety of materials allowing the proper material selection for your specific application The standard product features AL 29 4C or 316L stainless steel liner and a 430 stainless steel outer shell SUPPORT LIMITS Support plates and wall su...

Page 3: ...materials for all diameters and applications is 0 0mm JOINT ASSEMBLY 1 Join the non gasketed flange to the gasketed collared flange of the next section Install inner band around the two flanges and use a 3 8 nut driver to tighten inner band around sections Tap on inner band with rubber or rawhide mallet to ensure a proper tight joint 2 Rotate flange bolt into the corresponding notch of the clip an...

Page 4: ...ND ODD SIZES 45 LATERAL TEE Part No 45LT The 45 Lateral Tee is used for low flow resistance entry into a stack or breeching Includes 2 inner bands and 2 outer bands I D A B C 5 6 4 7 8 183 8 131 2 7 8 5 1 4 21 153 4 9 10 511 16 237 8 183 16 11 12 61 16 2611 16 209 16 13 14 6 1 2 29 1 2 23 15 16 615 16 325 16 257 8 17 18 7 5 16 353 16 2713 16 19 20 7 3 4 38 30 1 4 21 22 8 3 16 4013 16 3211 16 23 24...

Page 5: ... 26 18 28 21 30 24 24 26 15 28 18 30 21 32 24 26 28 15 30 18 32 21 34 24 28 30 15 32 18 34 21 36 24 30 32 15 34 18 36 21 38 24 32 34 15 36 18 38 21 40 24 34 36 15 38 18 40 21 42 24 36 38 15 40 18 42 21 44 24 38 40 15 42 18 44 21 46 24 40 42 15 44 18 46 21 48 24 42 44 15 46 18 48 21 44 46 15 48 18 46 48 15 48 Part No TI I D A B C 5 6 4 1 16 16 3 4 12 15 16 7 8 3 7 8 18 3 16 14 3 4 9 10 4 1 4 21 17 ...

Page 6: ... 90Y The 90 Wye is used for joining runs where low flow resistance is desired All openings must be the same size For connection to smaller diameter sections use the tapered or abrupt increasers Includes 2 inner bands and 2 outer bands Note Grease wye available 1 containment dam located at one opening I D A B 5 6 10 7 7 8 11 7 13 32 9 10 12 7 13 16 11 12 13 87 32 13 14 14 85 8 15 16 15 91 16 17 18 ...

Page 7: ...32 50 25 32 35 29 64 45 46 15 1 4 21 9 16 52 1 16 36 13 16 47 48 15 11 16 22 3 16 53 9 16 37 7 8 30 ELBOW Part No 30L The 30 Elbow is used when a vertical or horizontal direction change of 30 is desired Includes 1 inner and 1 outer band I D A B C D 5 6 6 1 8 6 1 8 22 55 64 13 13 64 7 8 6 3 8 6 3 8 23 51 64 13 47 64 9 10 6 5 8 6 5 8 24 23 32 14 9 32 11 12 6 15 16 6 15 16 25 57 64 14 61 64 13 14 7 3...

Page 8: ...tom closure and drain attachment for base supported vents Includes 1 inner and 1 outer band EXIT CONE Part No EXC The Exit Cone is used to increase the flue gas velocity exiting the stack A drain should be used at the base of stacks to remove any water that enters the stack Includes 1 inner band and 1 closure ring to seal outer shell joint I D A B 6 4 7 8 5 3 8 8 6 1 2 6 1 8 10 8 1 8 6 3 4 12 9 3 ...

Page 9: ...des 1 inner and 1 outer band Note Plenum boxes available for multiple fan systems HORIZONTAL TERMINATION Part No HT The Horizontal Termination is used when the stack terminates in a horizontal position Birdscreen covers the opening to prevent any birds or rodents from entering Includes 1 inner and 1 outer band GUY SECTION Part No GS The Guy Section is to be used when the chimney extends beyond the...

Page 10: ...ned to support B See Chart Below feet of vertical vent section as well as provide fixed points in breeching runs Includes 1 inner band and 2 half outer bands Note This part must be placed at the connection of two flue sections WALL SUPPORT Part No WS The Wall Support is used to provide vent support along a wall The wall support will maintain the required clearance to combustible structures when pr...

Page 11: ...bs Horizontal Drain HD 11 lbs Insulated Thimble IT 20 lbs Nozzle Section NS 11 lbs Rain Cap CC 9 lbs Rain Collar RC 4 lbs Support Plate SP 31 lbs Tapered Increaser TI 13 lbs Top Section TS 3 lbs Variable Section VS 23 lbs Wall Guide WG 14 lbs Wall Support WS 51 lbs Inside Diameter Inches All weights shown above are actual weights for shipping weights multiply by 1 25 8 10 12 14 16 18 20 22 24 26 2...

Page 12: ...n performed by Schebler personnel and the design parameters provided to The Schebler Company by the responsible engineer were and are accurately representative of the system operating conditions 2 The undamaged components have been correctly installed in accordance with Schebler system design and sizing and installation instructions published by The Schebler Company 3 All horizontal breeching in t...