background image

www.schweigen.com.au

RANGEHOOD & INSTALLATION GUIDE

DS3170-12S

Revision V3 31/01/20

Summary of Contents for DS3170-12S

Page 1: ...www schweigen com au RANGEHOOD INSTALLATION GUIDE DS3170 12S Revision V3 31 01 20...

Page 2: ...nterior 9 Cleaning the Exterior 9 Filters 10 Replacing the Lights 11 6 Installation 12 Rangehood Size vs Cooktop Size 12 Mounting Instructions 13 Recommended Installation Height for Induction Cooktop...

Page 3: ...website www schweigen com au This appliance and its packaging are produced by processes that minimise waste and respect the environment Please help us to continue this effort to protect the environmen...

Page 4: ...person s including children with reduced physical sensory or mental capabilities or lack of experience and or knowledge Unless the person has been given supervision or instruction concerning the use o...

Page 5: ...are made by a qualified technician and that the indicated instructions and local regulations in force are met using materials that are compliant with the applicable legislation 11 The company will no...

Page 6: ...ling cavity When a rangehood is ducted only into the ceiling space the collection of humidity and grease can present very real health issues and fire hazards Recirculating or non ducted or filtered ra...

Page 7: ...utlet 200mm 7 Reducer For Isodrive 650 motor only 8 Filters 9 Light NOTE Filter and light quantity may vary from model to model Important Electronics MUST be accessible for service and or maintenance...

Page 8: ...ght cooking High speed for heavy frying or heavy cooking Cleaning periods of metal filters C Signal Filter should be cleaned when C signal appears on the display on average this is every 4 to 5 weeks...

Page 9: ...y important for the liquid soap to not contain granules that could scratch the surface First apply the solution to a soft cloth and then rub the cloth over the rangehood It is important to follow the...

Page 10: ...r Dishwasher Put the filter in the dishwasher and select a short program at low temperature NOTE The colour of the metal mesh filters may change after several washes This is normal and it is not neces...

Page 11: ...he pins of the light bulb with the larger holes inside the light holder Once the pins are in place turn clockwise to secure the light bulb Step 1 Remove the filters from the rangehood Danger Always sw...

Page 12: ...ze In addition to the size the height of the rangehood above the cooktop is important to obtain the best performance INADEQUATE Rangehood smaller than cooking zone ADEQUATE Rangehood same size as cook...

Page 13: ...weigen recommends a height between 700 750mm Refer to page 19 for further information IMPORTANT If the user decides to install the rangehood at a distance of less than minimum height above the cooking...

Page 14: ...rface Please ensure that the holes for the two primary mounting points are level before installation 1 Primary Mounting Points 2 Adjust to Level 3 Secondary Mounting Points 17 12 38 34 336 5 298 204 2...

Page 15: ...f installation Secure rangehood to the wall using only primary mounting points 1 Check the level of the rangehood and adjust accordingly if necessary 2 Once level continue to secure the rangehood via...

Page 16: ...gth required Be careful not to scratch the top of the rangehood PLEASE NOTE Only a standard length of stainless steel flue is provided Any additional length will need to be sourced and manufactured by...

Page 17: ...le models The supplied ducting has been manufactured with an allowance for the back draft fins to operate without hindrance It is the smooth extended end of the ducting When installing Back Draft Fins...

Page 18: ...Amp 8 Flexi Ducting must be pulled taut DO NOT crush or kink the ducting 9 Connect flexi ducting to the outlet on rangehood using ring clamp Please DO NOT rip the ducting Pictures are for illustrative...

Page 19: ...istance from cooktop to the rangehood Speed of food liquid heating Filter size larger canopy preferred Quality of pots or cookware you are using high quality recommended How to reduce the possibility...

Page 20: ...ning Light bulbs should be firmly in position Check light bulbs Make sure they are not broken or faulty Please make sure there is no obstruction in ducting or with the back draft fins Check the outlet...

Page 21: ...ss to the appliance at their expense Service Lodging an Online Service Request In the event that the failure is not due to the faults mentioned in the Troubleshooting section you can lodge an online S...

Page 22: ..._n_ _LH Section_ Page 22 9 Specifications Technical Specifications Model DS3170 12S Feeding Voltage 220 240V 50Hz Lamp Power LED W 3 x 3W Dimensions 262 250 1200 500 Min 670 Max 1190 90...

Page 23: ...be found with the Isodrive Motor or online at schweigen com au Schweigen Home Appliances has presented this information in good faith to all their retailers and distributors to convey before any all p...

Page 24: ...Court Mulgrave 3170 Victoria Phone 1300 881 693 Email sales schweigen com au Web www schweigen com au New Zealand 5 Tolich Place Henderson Auckland 0610 Phone 0800 200 510 Email info parex emerson co...