ELECTRICINEMA Connect IP Projection Screen 

 

All inputs on module 1 are accessed by removing right hand end cap of screen canister 

1.

 

Contact Close Input  

a.

 

Contact Close Input for local control  

b.

 

Requires 2 x Momentary contacts duration minimum 50 milliseconds  

c.

 

Dedicated contact for Up & Down   

d.

 

Stop command is close opposite travel contact or both Up & Down together  

2.

 

DC Trigger Input  

a.

 

Down command is sent when a DC Voltage of 3 Volts @ 1mA minimum is applied to input, a  
Up command is sent  

b.

 

Up command is sent when a DC Voltage of less than 1.0 Volts DC @ 1mA is applied to input, a 
Down command is sent  

c.

 

Maximum cable length 75 meters approximately based 24 AWG gauge cable   

 
 
 
 

Summary of Contents for ELECTRICINEMA

Page 1: ...minimum 50 milliseconds c Dedicated contact for Up Down d Stop command is close opposite travel contact or both Up Down together 2 DC Trigger Input a Down command is sent when a DC Voltage of 3 Volts 1mA minimum is applied to input a Up command is sent b Up command is sent when a DC Voltage of less than 1 0 Volts DC 1mA is applied to input a Down command is sent c Maximum cable length 75 meters ap...

Page 2: ... Supplied with IR receiver with 300mm and 1 2M input lead c IR operates on Group 1 2 as standard 5 RJ45 LAN Input a DHCP or Static IP addressable b Internal Web Browser c TCP IP controllable 6 PC or Mac Connect Software a As the module is DHCP default this software will allow simple operation and identification of IP address and port number of IP connect modules on network b PC Connect software wi...

Page 3: ... of module via simple control g When command is sent string showing command IP address Port number and feedback response is shown in the box below h Click on Browser button and simple control screen appears i Click on login to view advanced settings page ...

Page 4: ...t User Name Admin e Password Connect 8 Connect Internal Web Browser a Select Direct Control from Control Menu b Direct Control Screen shown below c Partial 1 2 act as stop command unless partial has been programmed d MAF address and Module ID shown e Simple control feature f Status indication of screen use refresh to obtain latest status update ...

Page 5: ...ontrol a Direct Control Screens that have been programmed with the same IR group or switch group contact Close input b Partial 1 2 act as stop command unless partial has been programmed c Simple control feature ...

Page 6: ...10 IP Control Settings a Access settings via set up tab b Setting of static IP address c Mac address set up If replacing on network d Current IP operating parameters ...

Page 7: ...e AMX Discoverable enable f Screen Technics Beacon g Simple control page ...

Page 8: ...lecting System then Module Settings b Select MAF address or Module ID and select load c Change value and select update d This menu will enable changes of features within the module e 127 registers in total f Screen shot below showing register page ...

Page 9: ...ange register 75 to a value of 6 Commonly Used Registers Register Number 65 Operation PIN 66 Programming PIN 67 Partial Pos 1 Lo 68 Partial Pos 1 Hi 69 Partial Pos 2 Lo 70 Partial Pos 2 Hi 71 SWITCH MODE 72 Partial 1 Open Mode 73 Partial 2 Open Mode 74 SWITCH GROUP Bitmapped Register below 75 IR GROUP Bitmap Register Below 76 Timer Up 77 Timer Down 78 MODULE_ID 82 Time_delay_up 100mS 83 Time_delay...

Page 10: ...ule to operate on Switch Group 1 only change register 74 to a value of 2 c If you wish the module to operate on Group 1 2 only change register 74 to a value of 6 GROUP VALUE 1 2 2 4 3 8 4 16 5 32 6 64 7 128 8 256 9 512 TOTAL GROUP VALUE 1 2 2 4 3 8 4 16 5 32 6 64 7 128 8 256 9 512 TOTAL ...

Page 11: ... following table Transfer the Value for each required group to the right column The Total of the values in the right column then becomes the Register Value Eg to set groups 1 2 4 then the Total value is 22 GROUP VALUE 1 2 2 4 3 8 4 16 5 32 6 64 7 128 8 256 9 512 TOTAL ...

Page 12: ... 45 CR LF 1 3 45 CR LF 1 3 45 CR LF 1 3 45 CR LF 1 3 45 CR LF 1 3 45 CR LF 01 3 45 CR LF 000000001 3 45 CR LF 1 3 45 CR LF 1 3 45 CR LF A message is not a valid message if It contains more than 80 characters before an end of message character is received It contains a character that is not CR LF TAB SPACE 0 1 2 3 4 5 6 7 8 9 A numerical field exceeds 65535 It contains more than 10 fields If a pack...

Page 13: ...ct Network including the Connect IP module e g 30 0 will operate all devices connected via the Connect network e Example of direct command Connected to 192 168 0 32 3001 command30 1 using module ID would see the screen move to up position IR Group Commands f IR group control can be used to control screens directly if connected via Connect Network including the Connect IP module g Each module will ...

Page 14: ...on Switch group 1 move to up position d Command followed by value 0 operates all modules connected via Connect Network including the Connect IP module Operate Switch Group Command Switch Group Description 10 SWITCH Group 1 to 9 0 Operate Switch Group UP 11 SWITCH Group 1 to 9 0 Operate Switch Group PARTIAL 1 12 SWITCH Group 1 to 9 0 Operate Switch Group PARTIAL 2 13 SWITCH Group 1 to 9 0 Operate S...

Page 15: ...being used a IP address 192 168 0 32 3001 command 044 17 using unified address would see the screen set partial position 1 b To set Partial 2 stop screen at required location and send command if screen 1 is being used a IP address 192 168 0 32 3001 command 045 17 using unified address would see the screen set partial position 1 17 Module Status Feedback A module status buffer 20 record FIFO is update...

Page 16: ... being updated even though the status is the same Example of string from module 192 168 0 32 3001 Up Send 30 1 192 168 0 32 3001 Up Receive 130 1 1 192 168 0 32 3001 Status Change Receive 9999 192 168 0 32 3001 Get Module Status Send 67 3781 192 168 0 32 3001 Get Module Status Receive 167 0 255 255 255 255 255 255 255 255 192 168 0 32 3001 Status Change Receive 9999 192 168 0 32 3001 Get Module St...

Page 17: ... press for 5 seconds approximately Factory Default Mode selected LED double flashes Pressing button again exits mode Receiving an IR command exits this mode b Single short press for 3 seconds approximately Screen Rattle command 3 seconds down 1 second up LED single flashes while in this function Pressing button again stops screen Function is exited when screen operation finished or another screen ...

Page 18: ...le into static IP mode b You will need to set your network adaptor to look for IP range example shown c Default IP address is 192 168 1 254 http 192 168 1 254 Into browser address bar Input User Name Admin Password Connect You should now see the direct control screen You can now access the settings for the Connect IP module ...

Page 19: ...e limit position up or down Clockwise turning of the switch will always let the motor travel further in that direction Anti clockwise turning of the switch will lessen the amount of travel in that direction Can I adjust the switch while the screen is sitting on the limit ie fully up or down Clockwise adjustment YES But it is better to back the screen away from the limit and then adjust Anti clockw...

Reviews: