background image

TB-9107

 Page 1 of 14

© 2021 DESCO INDUSTRIES INC

Employee Owned

SCS 

- 926 JR Industrial Drive, Sanford, NC 27332

East: (919) 718-0000 | West: (909) 627-9634 • Website: 

StaticControl.com

Ion Pro™ Benchtop Ionizer

Installation, Operation and Maintenance

December 2021

Description

The SCS Ion Pro™ Benchtop Ionizer is used for 

neutralizing electrostatic charges on insulators and 

ungrounded conductors. Its fast discharge times (< 1.5 

seconds at 12 inches) and ±3 volt offset voltage exceed 

the required limits of ANSI/ESD S20.20 and ESD TR53. 

The Ion Pro Benchtop Ionizer monitors both its offset 

voltage (balance) and discharge time. The ionizer will 

alarm should its offset voltage exceed the required 

limits defined by ANSI/ESD S20.20 or discharge time 

take longer than 4.5 seconds. Steady-state DC emitters 

are spaced farther apart to prevent ion recombination, 

increase decay efficiency, and provide a broader 

coverage area of ionization. The Ion Pro™ Benchtop 

Ionizer’s dual-speed fan produces consistent airflow 

performance. The Ion Pro™ Benchtop Ionizer features 

a stainless steel enclosure and multi-mount stand to 

minimize contamination and corrosion when used in 

clean or sensitive areas.
The SCS Ion Pro™ Benchtop Ionizer operates on 

Steady-state DC. Steady-state DC systems consist of 

separate negative and positive ion emitters connected 

by a pair of high-voltage cables to their respective 

high-voltage power supplies. DC power is constantly 

applied to the emitter points. The ionizer utilizes 

patented capacitance-based sampling from its internal 

sensor to continuously adjust the output, maintain its 

offset voltage, and minimize maintenance.

Made in the

United States of America

 USER GUIDE TB-9107

“The primary method of static charge control is direct 

connection to ground for conductors, static dissipative 

materials, and personnel. A complete static control 

program must also deal with isolated conductors 

that cannot be grounded, insulating materials (e.g., 

most common plastics), and moving personnel who 

cannot use wrist or heel straps or ESD control flooring 

and footwear. Air ionization is not a replacement for 

grounding methods. It is one component of a complete 

static control program. Ionizers are used when it is not 

possible to properly ground everything and as backup 

to other static control methods. In clean rooms, air 

ionization may be one of the few methods of static 

control available.” [ESD Handbook ESD TR20.20 

Ionization, section 5.3.6.1 Introduction and Purpose / 

General Information]
The Ion Pro™ Benchtop Ionizer and its accessories are 

available as the following item numbers:

Item

Description

770116

Ion Pro™ Benchtop Ionizer, 120 VAC

770117

Ion Pro™ Benchtop Ionizer, 220 VAC

770000

Power Cord, North America Plug

770001

Power Cord, UK Plug

770002

Power Cord, Europe Plug

770003

Power Cord, China Plug

770118

Power Cord, Daisy Chain

770047

Benchtop Ionizer Boom Arm

770055

SMP Software

Figure 1. SCS Ion Pro™ Benchtop Ionizer

Static Management Program

The SCS Ion Pro™ Benchtop Ionizer is compatible 

with SCS Static Management Program (SMP). SMP 

continuously monitors your ESD process control system 

throughout all stages of manufacturing. SMP captures 

data from SCS workstation, equipment and ESD event 

continuous monitors and provides a real-time picture of 

critical manufacturing processes. All activity is stored 

into a database for on-going quality control purposes. 

SMP allows you to pinpoint areas of concern and 

prevent ESD events. Quantifiable data allows you to see 

trends, become more proactive and prove the efficiency 

of your ESD process control system. When paired with 

the Ion Pro Benchtop™ Ionizer, SMP will monitor its 

balance (offset voltage) and discharge time statuses.
SMP is sold separately. 

Click here

 to learn more.

Summary of Contents for 770116

Page 1: ...for conductors static dissipative materials and personnel A complete static control program must also deal with isolated conductors that cannot be grounded insulating materials e g most common plasti...

Page 2: ...8th setting disables the buzzer Balance Alarm CE Mode 1 Power the ionizer OFF 2 Push and hold the switch while restoring power to the ionizer 3 The buzzer will chirp once to indicate that it is in Cri...

Page 3: ...ct the ionizer s power cord into an appropriate AC power source Note that placement of the ionizer is important in determining its effectiveness The distance from the targeted object and fan speed aff...

Page 4: ...t the Ethernet cable is securely connected to your network and Ion Pro Benchtop Ionizer The LEDs on the Ethernet port will illuminate when a connection to the network is established 2 Open SCS SMP Ser...

Page 5: ...909 627 9634 Website StaticControl com 5 A message will appear and display Starting SMP Server Click the SMP Server icon located in the Windows taskbar 6 SMP Server will now indicate Active server sta...

Page 6: ...Drive Sanford NC 27332 East 919 718 0000 West 909 627 9634 Website StaticControl com 8 Open SCS SMP Admin 9 The window for SMP Server Admin will appear 1 unassigned is representative of the Ion Pro B...

Page 7: ...d NC 27332 East 919 718 0000 West 909 627 9634 Website StaticControl com 10 Enter a building name and then click the OK button 11 The building name will appear on the navigation pane in SMP Server Adm...

Page 8: ...anford NC 27332 East 919 718 0000 West 909 627 9634 Website StaticControl com 13 Enter a floor name and then click the OK button 14 The floor name will appear on the navigation pane in SMP Server Admi...

Page 9: ...t 919 718 0000 West 909 627 9634 Website StaticControl com 16 Enter a line name and then click the OK button 17 The line name will appear on the navigation pane in SMP Server Admin 18 Click on the lin...

Page 10: ...com 19 The serial number for the Ion Pro Benchtop Ionizer will appear This number will resemble the number found on the monitor s serial label with the exception of one zero For example if the serial...

Page 11: ...NC Employee Owned SCS 926 JR Industrial Drive Sanford NC 27332 East 919 718 0000 West 909 627 9634 Website StaticControl com 21 Open SCS SMP Client 22 Verify that the Ion Pro Benchtop Ionizer was adde...

Page 12: ...ild soap with water may be used The use of any other cleaning solutions is not recommended CLEANING THE EMITTER POINTS NOTE Disconnect the power to the ionizer whenever cleaning the emitter points Whe...

Page 13: ...at it is performing within specifications These measurements should be taken using a charged plate monitor Calibration should be performed in accordance with the ESD Association ionization standard AN...

Page 14: ...irflow Dual speed 77 CFM max Ozone 0 05 ppm Discharge Time Alarm Threshold at 12 4 5 s Offset Voltage Alarm Threshold Standard Mode 35 V approx Offset Voltage Alarm Threshold CE Mode 7 V approx Power...

Page 15: ...Mouser Electronics Authorized Distributor Click to View Pricing Inventory Delivery Lifecycle Information SCS 770116 770117 770118...