background image

1. Mark and drill as follows:  Holes 1, 2 and 3 for #14 sheet metal screws or 1/4 - 20 machine screws.

Hole 4 – 3/8" diameter for wire.
Block strike:  Holes 5 and 6 or 12 and 13 for 1/4 - 20 machine screw or #14 sheet metal screw.

2. Tap holes as required.

3. Remove housing cover and mount lock and strike.

4. Attach power leads.  Check alignment of bolt and strike.  There should be no binding.  Leading part of 

strike should be 1/8" away from the lock 

1/8" is maximum distance

.  If this is correct, tighten mounting 

screws.

5. Check lock operation for any last adjustments.

6. Install housing.

SPECIFICATIONS

DIMENSIONS:  2" x 2" x 6"

FINISH:  US28 standard (dark duranodic optional)

BOLT:  280 series 5/8" diameter 1/2” throw

SOLENOID:  280 series, power lock, continuous duty

280 Series Dual Voltage (Fail Safe):

10.8 Watts – 12VDC @ .9 Amp
10.8 Watts – 24VDC @ .45 Amp

12VDC
CONFIGURATION
.9 AMP

RED

WHT (-)

WHT

BLU

BLK

RED (+)

24VDC
CONFIGURATION
.45 AMP

RED

WHT (-)

WHT

BLU

BLK

RED (+)

Any suggestions or comments to this instruction or 

product are welcome.  Please contact us through 

our website or email engineer@sdcsecurity.com 

P:\INSTALLATION INST\Electric Bolt Locks\TEMP-180-280\INST-280.vsd   REV - 09-13   Page 1

INSTALLATION INSTRUCTIONS/TEMPLATE

280 SERIES ELECTRIC LOCKS

801 Avenida Acaso, Camarillo, Ca. 93012  •   (805) 494-0622  •
www.sdcsecurity.com  •  E-mail: service@sdcsecurity.com

BOLT POSITION SENSOR

or

DOOR POSITION SENSOR

SPDT  .25 AMP

RED – N.C.

WHT – COM

BLU – N.O.

Reviews: