Features

Keypad programmable
500 user codes
4 to 6 digit user codes
4 independent outputs
4 independent timers
2 Form C relay contacts
2 solid state open collector outputs
Program entry codes to activate one or 
two relays
Disable input
Door sense input
Request-to-exit/enter input
Keypad tamper lockout
Timed anti-passback
Anti-tailgate
Two LED status indicators
Tactile key feel
Audible code entry verification
12 or 24V, AC or DC operation

The 923 Indoor/Outdoor Keypad Surface Mount 

EntryCheck

™ is a digital 

keyless entry system designed for access control applications. The  
keypad is integrated in a heavy cast vandal resistant housing, designed to 
be mounted on a  rugged, surface mounting plate and may be mounted in 
a standard single-gang electrical box.  The indoor/outdoor backlit keys  
have bright, easy-to-read  graphics.

Up to 500 entry codes, from 1 to 6 digits in length, can be programmed.  
They can activate either, or both of the relay outputs.  The “anti-passback” 
feature prevents using the same code again before the programmed time 
elapses.

All system indicators are long-lasting, solid state LEDs.  Two indicators 
show the status of the entry system.  The left indicator lights red to 
indicate power, then turns green when access is granted.  The right yellow 
LED flashes when the keypad is in programming mode.  An internal 
sounder beeps when each key is pressed.  An internal jumper sets the 
sounder volume high or low

The 

SENSE 

input can be used two ways.  If programmed for “door sense” 

the input is wired to a normally closed switch on the door to detect when 
the door is opened or closed.  Forced entry or door ajar situations can 
then be detected.  Using door sense, the “Auto-relock” feature will prevent 
“tailgating” by turning off the Main Relay output immediately when the 
door is closed after access has been granted.  If the 

SENSE 

input is 

programmed for “inhibit”, the input can be wired to a “service” switch or 
automatic timer that will disable the Main Relay when required.

The 

REQUEST-TO-EXIT 

input can be wired to a pushbutton to provide 

codeless activation of Main Relay, Auxiliary Relay, Output #3 or Output #4 
(programmable).

The 

ALARM SHUNT 

output activates when access is granted.  This 

output can be wired to shunt alarm contacts on the access door/gate to 
prevent triggering of an alarm when authorized access occurs.

The 923 

EntryCheck

™ is powered from a 12 or 24V AC or DC source.    

The EEPROM memory retains all entry codes and programming, even 
without power.  An internal jumper is provided to reset the master code.  
The Main Relay has a 5 Amp capacity.  The Auxiliary Relay has a 2 Amp 
capacity.  Two solid state outputs, capable of switching 100 mA to 
common, are programmable to signal forced entry, door ajar, lockout, 
alarm circuit shunting, request-to-exit, and keypad active conditions.

Any suggestions or comments to this instruction or 

product are welcome.  Please contact us through 

our website or email engineer@sdcsecurity.com 

P:\INSTALLATION INST\Access Controls\INST-923\INST-923.vsd     Rev F     05-19     Page 1

INSTALLATION INSTRUCTIONS

923 EntryCheck 

TM

801 Avenida Acaso, Camarillo, Ca. 93012  •   (805) 494-0622  •
www.sdcsecurity.com  •  E-mail: service@sdcsecurity.com

SPECIFICATIONS

Mechanical

Dimensions: 1.750" W x 7.3125" H x 1.375" D

(1.4375” wall projection)

Electrical

Input Voltage: 12/24 Volts AC or DC
Operating Current: 30 mA typical, 150 mA max

Output Ratings

Main Relay: Form “C” 5 Amps @ 28 Volts max

Auxiliary Relay: Form “C” 2 Amp @ 28 Volts max

Type:  Solid state outputs (Outputs #3 & #4)
Short-to-common 100 mA @ 24 VDC maximum

Environmental

Temperature: -4°F to 140°F (-20°C to 60°C)
Humidity: 5% to 95% non-condensing

Summary of Contents for EntryCheck 923

Page 1: ...ill prevent tailgating by turning off the Main Relay output immediately when the door is closed after access has been granted If the SENSE input is programmed for inhibit the input can be wired to a service switch or automatic timer that will disable the Main Relay when required The REQUEST TO EXIT input can be wired to a pushbutton to provide codeless activation of Main Relay Auxiliary Relay Outp...

Page 2: ...56 Enter the program mode default master code Step 2 Enter 03 4 Set the entry code length to 4 digits Step 3 Enter 21 5 Set the main relay activation time for 5 sec Step 4 Enter Exit programming mode QuickStart Programming You must first enter programming mode to perform any function The yellow indicator will blink slowly showing that the 923 EntryCheck is in programming mode Use the option codes ...

Page 3: ...es this unit must be connected to a proper earth ground Connect the green earth ground wire to a good earth grounding point Suggested wiring size is 18 AWG for earth ground Sense Input RE Note The SENSE input gray wire can be programmed as either a door sense or inhibit input Both features cannot be used at the same time If you are not using the sense input program this input for inhibit Door Sens...

Page 4: ...ation in memory The green indicator will light when the new user is accepted If the user number already exists or an entry error has been made the red indicator will light Delete the user and re enter the new information again Note Leading zeros zeros before the Code number i e 0001 do not need to be entered when programming a new code The 923 will internally add any zeros to fill digits determine...

Page 5: ... No Output Select Keypad Lockout Output Default No Output Sets which output activates when the keypad is locked out after too many incorrect entry code attempts The lockout time is 60 seconds Press 1 3 Output Output Output to Activate 0 4 1 Main Relay 2 Auxiliary Relay 3 Output 3 4 Output 4 0 No Output Select Alarm Shunt Output Default No Output Sets which output activates during the time access i...

Page 6: ... Locate Remove jumper at JP2 Reference page 2 STEP 3 Re apply power You will get a single beep and the yellow LED will flash momentarily STEP 4 Replace jumper on JP2 THE MASTER PROGRAMMING CODE IS NOW 123456 Beep Sounds During Main Relay Default No Selects whether or not the keypad beeps during Main Relay activation Press 4 1 Sound Sound 1 for Yes 0 for No Solid state Output 4 On time Default 02 S...

Page 7: ...P INSTALLATION INST Access Controls INST 923 INST 923 vsd Rev F 05 19 Page 7 4X Mount at holes With supplied screws and hole expansion anchors 1 375 7 3125 1 750 WALL MOUNT MULLION MOUNT ...

Reviews: