1) Product description
The keypads, according to initial settings, can transmit as fixed code or Rolling code multiple SEA protocols (see parag. 2.1).
The estimated transmission range is 80 m in open spaces and 50 m indoor.
The units are designed to ensure battery life equivalent to an estimated of 2 years of operation considering 10 transmissions/day. However, it is
recommended to replace it every 12 months to ensure optimal performance, especially in locations subject to high temperature ranges
.
Audible signal Status
2) Installation
Before physically installing the keypad in its mouning position, set the keypad in desired transmission mode, fixed code or Rolling Code Plus code. It is good
practice to perform a practical test to assess its functionality and effective range. Consider that range may be up to 25 or 30% less when battery is low or in
the presence of metal structures. The keypad should be learned by the memory of a receiver compatible like a standard transmitter, pressing the control
buttons. For more details refer to the manual of the used receiver.
2.1) Transmission mode setting
When turning on, press and hold the buttons 1 and 3 for Rolling Code Plus setting, or press the buttons 4 and 6 for fixed code setting (HT12).
2.2) Positioning
The unit should not be positioned in contact with metal structures, which could otherwise exert a signal shielding effect.
Thanks to the box protection rating of IP 54, the digital keypads can be installed on the outside if required. However, it is preferable, where possible, to
protect them from rain.
3) Method of use
The use of the keypad is based on "combinations", i.e. numbers of, from 1 to 5 digits, that the user is required to key in by means of the keys. Once the
combination has been entered the user then presses the confirm key if you need to transmit channel 1, or confirm key if you need to transmit
channel 2:
- Channel 1 if the user presses
- Channel 2 if the user presses
The command will be transmitted only when a valid combination has been entered
- if the entered combination is wrong the selector will emit an error waming signal when the confirm key is pressed. The combination entered must be exact,
if for example, the combination is 0422, the following attempts will be interpreted as errors: 422, 10422, 04222. Therefore, if the user inadvertently presses
the wrong key when entering a combination, combination key or should be pressed immediately to generate the error tone, after which the correct
combination can be entered starting from the beginning again.
While entering the combination no more than 6 seconds can be allowed to elapse between keystrokes, otehrwise the combination must be re-entered
starting from the beginning.
The keybad is programmed at the factory with a MASTER code to activate the programming procedure.
• MASTER CODE = 0
9999
KEYPAD PROGRAMMING
•
To enter into programming mode you must enter the MASTER code: 0
9999
This code (factory setting) can be changed (see submenu 6).
You will hear a long beep (2 sec.) and the LED will flash to confirm the entry into the programming menu. If you do not select any button within 20
seconds, the keypad will automatically exit this state. At this point, select one of the submenus below to access the various functions.
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
English
SEA S.p.A.
Zona industriale 64020 S.ATTO Teramo - (ITALY)
Tel. +39 0861 588341 r.a. Fax +39 0861 588344
www.seateam.com seacom@seateam.com
2XCR2032 (6V)
Rolling code 72 bit
2/800
433.920Mhz
-20°C +60°C
-30°C +80°C
84x74x37
from 5% to 90% no condensation
Technical Characteristics
Power supply
Encoding
Channels/Codes
Frequency
Working Temperature
Warehousing Temperature
Dimensions
Humidity
3
1 bip Button pressure
1 bip of 2 sec. Entry into programming mode
1 bip of 1 sec. Entry into submenu
5 bip of 0.5 sec. Error during combination input or combined edit operation
Multitone high Valide code
Multitone low Wrong code
67411895
QUICK START
Example of Quick programming
code 4591:
4591 code test
>
>
>
>
0 9999 1
4591
>
>
>
>
>
>
>
>
>
>
>
Wait until the LEDs are off
ROCK RF PLUS
Wireless keypad (23105194)
ROCK RF METAL
Wireless keypad (23105199)
Rev.02 - 10/2015