User manual

SMART DRY

dehumidifier

Model:  

SMTD-201710V2EP

Summary of Contents for SMTD-201710V2EP

Page 1: ...User manual SMART DRY dehumidifier Model SMTD 201710V2EP ...

Page 2: ......

Page 3: ...1 1 3 3 4 5 6 7 8 9 10 11 12 ...

Page 4: ...m the air by compressor dehumidifying This unit will help to keep carpets floors walls and other ar cles in a room dry and free from mildew The Seago Smart Dry is ideal to use on a boat file rooms storage unit or in any room space that needs to maintain a dry environment This compact unit can be le working con nuously when the external drain pipe is connected ...

Page 5: ...ppliance may cause harm to people or animals Do not stand too close to the unit Do not operate this unit near flammable or explosive materials Do not put your hands or other objects into the air outlet Do not touch the power switch or outlet with wet hands danger of electric shock This unit must be turned on off in the correct way Repeated connec ng disconnec ng from the outlet without correctly tur...

Page 6: ...e P ower c ord A er tes ng some water may remain in the tank this is normal A Dehumidifier opera on A er connec ng the power cord to the power outlet the following will show a Power indicator led b Display screen will show ambient humidity c The unit will go into standby B Press the ON OFF bu on once to ac vate the dehumidifier ...

Page 7: ... when the desired running me has been reached If the tank becomes full or the compressor becomes frosted the unit will stop running and the mer will con nue In the event of a power loss the unit will reboot with the previous se ngs the mer will be cancelled G Humidity se ng The humidity se ng control will turn on and off the unit depending on the ambient humidity and the level of humidity that it i...

Page 8: ...space around the air inlet outlet is clear There must be free air flow for to op mum performance and energy conserav on E To operate the Smart Dry in con nuos mode the use of an external drain pipe is needed Follow these instruc ons for con nuos drain mode Connect 9mm drainage pipe to the hose connector and secure it to avoid any leakage A For best performance posi on the unit in accordance to the ...

Page 9: ...place the water tank The drainage pipe will fit in the slot on the water tank NOTE For con uous drainage to work the unit must always be higher than the drainage pipe The drainage pipe should not have any kinks twists or knots and must allow water to flow freely ...

Page 10: ...ater tank is full the indicator will show red and an audible beep will be heard The unit will go into standby mode un l the tank is emp ed Timer indicator When in mer mode the indicator will show green Quiet indicator When the unit is running in quiet mode the indicator will show green Dry indicator When in dry mode the indicator will show red ...

Page 11: ... A Do not remove the float switch this will stop the unit running B To rinse the tank use cold or warm water C Ensure the water tank is fully engaged If the tank is not fully engaged the unit will not run ...

Page 12: ...h a vacuum or wash it with warm water not higher than 40 C c Shake of excess water and air dry do not expose to the sun for long periods Install in the unit once dry B Check the drainage water pipe It is necessary to keep the water pipe unobstructed to drain the water smoothly and make the unit work correctly You should check the water pipe regularly and replace it if necessary C Do not use the un...

Page 13: ...ra on problems i e opera ng noise will become higher Residual water in the unit will run over H Storing the Smart Dry a Ensure the water tank is empty and the power cord is unplugged b Coil up the power cord c Clear the air filter d Store in a dry clean environment ...

Page 14: ... increase room temperature The humidity is set higher than the ambient humidity Adjust the humidity se ng to be lower than the ambient humidity Drianage pipe is blocked Check drainage pipe and replace if necessary Rela ve humidity se ng not reached a er long period of opera on Doors and windows are not closed or sealing capacity of ambient room is not good Close any windows and doors Ensure the sp...

Page 15: ... RATED INPUT POWER 200W AIR VOLUME 100m h WORKING SPACE 10 20m WORKING TEMPERATURE 5 32 C REFRIGERANT R134a NOISE LEVEL 42dB COMPRESSOR PISTON TYPE CONTROL MODEL ELECTRONIC WATER TANK CAPACITY 1 8L PRODUCT SIZE 287x169x488mm NET WEIGHT 10 kg GROSS WEIGHT 11 5 kg DEHUMIDIFYING CAPACITY ...