PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS.  USE THE PRODUCT 

CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL 

INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.

Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these 

instructions and maintained properly, give you years of trouble free performance.

Refer to Instruction 

Manual

Warning:

electricity

 1.  SAFETY

COMPRESSOR 50LTR/100LTR V-TWIN

DIRECT DRIVE 3HP

MODEL NO’S :

 SAC05030.V2, SAC10030.V2

1.1.

 

ELECTRICAL SAFETY

   

WARNING!

 It is the responsibility of the owner and the operator to read, understand and comply with the following:

   

You must check all electrical products, before use, to ensure that they are safe. You must inspect power cables, plugs, sockets and    

   

any other connectors for wear or damage. You must ensure that the risk of electric shock is minimised by the installation of  

 

   

appropriate safety devices. A Residual Current Circuit Breaker (RCCB) should be incorporated in the main distribution board. We also  

   

recommend that a Residual Current Device (RCD) is used. It is particularly important to use an RCD with portable products that are    

   

plugged into a supply which is not protected by an RCCB. If in any doubt consult a qualified electrician. You may obtain a Residual    

   

Current Device by contacting your Sealey dealer. 

   

You must also read and understand the following instructions concerning electrical safety.

1.1.1.  The Electricity at Work Act 1989 requires that all portable electrical appliances, if used on business premises, are tested by a qualified  

 

electrician, using a Portable Appliance Tester (PAT), at suitable intervals.

1.1.2.  The Health & Safety at Work Act 1974 makes owners of electrical appliances responsible for the safe condition of those appliances    

 

and the safety of the appliance operators. If in any doubt about electrical safety, contact a qualified electrician.

1.1.3.  Ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply. See 1.1.1. and 1.1.2.    

 

and use a Portable Appliance Tester.

1.1.4.  Ensure that cables are always protected against short circuit and overload.

1.1.5.  Regularly inspect power supply cables and plugs for wear or damage and check all

 

connections to ensure that none are loose.

1.1.6.  Important: Ensure that the voltage marked on the appliance matches the power supply 

 

to be used and that the plug is fitted with the correct fuse - see fuse rating at right.

1.1.7. 

DO NOT

 pull or carry the appliance by the power cable.

1.1.8. 

DO NOT

 pull the plug from the socket by the cable.

1.1.9.

  DO NOT

 use worn or damaged cables, plugs or connectors. Immediately have any faulty 

 

item repaired or replaced by a qualified electrician. When a BS 1363/A UK 3 pin plug is 

 

damaged, cut the cable just above the plug and dispose of the plug safely. 

 

Fit a new plug according to the following instructions (UK only).

 

a) Connect the GREEN/YELLOW earth wire to the earth terminal ‘E’.

 

b) Connect the BROWN live wire to the live terminal ‘L’.

 

c) Connect the BLUE neutral wire to the neutral terminal ‘N’.

 

d) After wiring, check that there are no bare wires, that all wires have been correctly connected,

 

that the cable outer insulation extends beyond the cable restraint and that the restraint is tight.

 

Double insulated products, which are always marked with this symbol    , are fitted with live (brown) and neutral (blue) wires only. 

 

To rewire, connect the wires as indicated above - 

DO NOT

 connect either wire to the earth terminal.

1.1.10.  Products which require more than 13 amps are supplied without a plug. In this case you must contact a qualified electrician to ensure  

 

that a suitably rated supply is available. We recommend that you discuss the installation of an industrial round pin plug and socket    

 

with your electrician.

1.1.11.  If an extension reel is used it should be fully unwound before connection. A reel with an RCD fitted is preferred since any appliance    

 

plugged into it will be protected. The cable core section is important and should be at least 1.5mm², but to be absolutely sure that the  

 

capacity of the reel is suitable for this product and for others which may be used in the other output sockets, we recommend the use   

 

of 2.5mm² section cable.

1.2.      GENERAL SAFETY 

 

Familiarise yourself with the application and limitations of the compressor.  

 

Ensure the compressor is in good condition before use. If in any doubt do not use the unit and contact an electrician/service agent.

 

WARNING! Compressor must only be serviced by an authorised agent. DO NOT tamper with, or attempt to adjust, pressure   

 

switch or safety valve.

 

Before moving or maintaining the compressor ensure it is unplugged from the mains supply, and that the air tank pressure has been   

 vented. 

 

Only use recommended attachments and parts. To use unapproved items may be dangerous and will invalidate your warranty.

 

Read the instructions regarding any accessory used with the compressor. Ensure the safe working pressure of any air appliance used  

 

exceeds unit’s output pressure.

 

Ensure the air supply valve is turned off before disconnecting the air supply hose.

 

To move the compressor use the handle only.  SAC05030 only - lift the compressor so that the front feet have enough clearance for    

 

manoeuvring, but maintain the unit’s stability.

 

DO NOT

 attempt to lift or move the compressor by any means other than by the handle. 

 

Use the compressor in a well ventilated area with a temperature above 5°C, and ensure it is placed on a firm, level surface.

Recommended fuse 

rating: 13A

SAC05030.V2, SAC10030.V2  Issue: 2 (L) -15/08/18

Original Language Version

 © Jack Sealey Limited

Summary of Contents for 50LTR V-TWIN

Page 1: ... NOT use worn or damaged cables plugs or connectors Immediately have any faulty item repaired or replaced by a qualified electrician When a BS 1363 A UK 3 pin plug is damaged cut the cable just above the plug and dispose of the plug safely Fit a new plug according to the following instructions UK only a Connect the GREEN YELLOW earth wire to the earth terminal E b Connect the BROWN live wire to th...

Page 2: ...ried out annually The tank shell must not fall below the certified thickness at any point Inspection of pressure tank both internal and external Under the PRESSURE SYSTEMS SAFETY REGULATIONS 2000 it is the responsibility of the owner of the compressor to initiate a system of inspection that both defines the frequency of the inspection and appoints a person who has specific responsibility for carry...

Page 3: ...elow the minimum threshold approx 2 bar 29psi less than the maximum pressure 5 3 5 Stop the compressor by pushing the switch knob downwards fig 3 A The compressed air inside the compressor head will exhaust making the restart easier and preventing the motor from being damaged DO NOT other than in an emergency stop the compressor by switching off the mains socket or by pulling the plug out of the s...

Page 4: ...h fresh oil through the oil filler breather aperture Do not overfill Replace oil filler breather plug WARNING Never mix different oils and do not use non detergent low quality oils as the compressor may be damaged Recommended oils Recommended oil for compressors suitable for temperatures ranging from 5 C to 25 C SEALEY CPO or equivalent SAE 40 compressor oil WARNING Dispose of waste oil only in ac...

Page 5: ...button Remove extension lead and test the compressor by connecting as near to the main fuse box as possible Extension lead too long Head unloader not operating Section 4 3 5 Contact Authorised Service Agent Occasionally the start up load may activate switch NOTE It is our policy to improve products continually and as such we reserve the right to alter data specifications and component parts withou...