background image

InstructIons for:

EXHAUST FUME EXTRACTION SYSTEM 

230V - 0.5hp - SINGLE HOSE & DOUBLE HOSE

Model no's:

 

EFS100F & EFS101 & EFS102 

thank  you  for  purchasing  a  sealey  product.  Manufactured  to  a  high  standard  this  product  will,  if  used  according  to  these  instructions 

and properly maintained, give you years of trouble free performance.

IMPORTANT:

 

PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS AND CAUTIONS. 

USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE 

AND/OR  PERSONAL  INJURY  AND  WILL  INVALIDATE  THE  WARRANTY.  PLEASE  KEEP  INSTRUCTIONS  SAFE  FOR  FUTURE  USE.

1.  SAFETY INSTRUCTIONS

Original Language Version

e  efs102     Issue no.1 - 02/12/11

3.  CONTENTS

3.1.

  unpack the equipment and check against the list below for  

 

missing or damaged items. In the event of a fault contact the  

 

supplier.

 

1. extractor unit.

 

2. extractor cone & flange inlet assembly.

 

3. exhaust hosing (5mtr).

2.  INTRODUCTION & SPECIFICATION

Wall mounted electric fan fitted with heat resistant hosing and 

exhaust gas analyser port. Ideal for bikes, cars and car derived vans. 

requires installation onto workshop wall and ducting to appropriate 

exhaust. does not include electrical switch gear. Ideal for smaller 

garages and workshops where space is limited.

Specification:

Motor ........................................................................ 0.5hp 230V 50Hz

Hose size ......................................................................Ø75mm x 5mtr

4.  INSTALLATION

4.1.  WE RECOMMEND THAT ELECTRICAL INSTALLATION  

 

SHOULD ONLY BE CARRIED OUT BY A QUALIFIED  

 

ELECTRICIAN.

Note: 

this product is designed to be hard wired into a building  

 

electrical circuit. 

4.1.1.  the power cable (not supplied) is wired to the unit through the  

 

power supply connection box (refer to fig.2 & fig.3). A wiring  

 

diagram (fig.1) is embossed inside the power supply  

 

connection box cover as a guide to the correct connection of  

 

the power cable.  

4.2.  WALL MOUNTING. 

the exhaust extractor should be mounted  

 

in such a position that it will not cause an obstruction or  

 

present a hazard in the work area.

4.2.1.  the exhaust extractor should be fixed to a brick or concrete  

 

wall through the wall mounting holes in the extractor main  

 

body using fixings that will adequately support the weight of  

 

the unit and the hosing. If in any doubt, seek professional  

 

advice.

4.2.2.  suitable ducting (not supplied) should be used to pass the  

 

exhaust gases from the outlet (refer to fig.2 & fig.3) to a safe  

 

environment. the ducting should be kept as straight and level  

 

as is practical to allow unrestricted egress of the exhaust  

 

gases.

4.2.3.  Attach the heat resisting hosing to the inlets (refer to fig.2 &  

 

fig.3) and to the cones using the clamps supplied.  

 

1.1.  ELECTRICAL SAFETY

  

WARNING!

 It is the responsibility of the owner and the operator 

to read, understand and comply with the following: 

You must check all electrical products, before use, to ensure that they 

are safe. You must inspect power cables, plugs, sockets and any 

other connectors for wear or damage. You must ensure that the risk 

of electric shock is minimised by the installation of appropriate safety 

devices. A residual current circuit Breaker (rccB) should be 

incorporated in the main distribution board. We also recommend that 

a residual current device (rcd) is used. It is particularly important 

to use an rcd with portable products that are plugged into a supply 

which is not protected by an rccB. If in any doubt consult a 

qualified electrician. You may obtain a residual current device by 

contacting your sealey dealer. You must also read and understand 

the following instructions concerning electrical safety.

1.1.1.  the 

Health & Safety at Work Act 1974

 makes owners of  

 

electrical appliances responsible for the safe condition of  

 

those appliances and the safety of the appliance operators. If  

 

in any doubt about electrical safety, contact a qualified  

 

electrician.

1.1.2.  ensure that the insulation on all cables and on the appliance  

 

is safe before connecting it to the power supply. 

1.1.3.  ensure that cables are always protected against short circuit  

 

and overload.

1.1.4.  regularly inspect power supply cables and plugs for wear or  

 

damage and check all connections to ensure that none is loose.

1.1.5. 

Important:

 ensure that the voltage marked on the appliance  

 

matches the power supply to be used.

1.1.6. 

DO NOT

 use worn or damaged cables, plugs or connectors.  

 

Immediately have any faulty item repaired or replaced by a  

 

qualified electrician.

1.2.  GENERAL SAFETY

 

WARNING!

 

Ensure Health & Safety, local authority, and  

 

general workshop practice regulations are adhered to when  

 

using this equipment.

 

familiarise yourself with the application, limitations and  

 

potential hazards of the extractor.

 

WARNING! Disconnect the unit from the mains power  

 

before servicing or performing any maintenance.

 

Maintain the extractor in good condition (use an authorised  

 

service agent).

 

replace or repair damaged parts. 

Use genuine parts only.  

 

Unauthorised parts may be dangerous and will invalidate the  

 

warranty.

 

locate the extractor in a suitable working area, keep area clean  

 

and tidy and free from unrelated materials. ensure there is  

 

adequate lighting.

 

ensure there are no flammable or combustible materials near  

 

the work area.

 

WARNING!

 

The exhaust gases from the outlet of the fan  

 

will be hot.

  

 

ensure that ducting is not located close to any flammable  

 

materials

 

ensure that the material used for the ducting from the outlet is  

 

heat resistant and flame retardant.

 

ensure that the exhaust gases are released outside of the  

 

workshop building. 

 

regularly check exhaust hosing and ducting for leaks.

 

ensure that there is a vacuum at the extractor cone before  

 

connecting to the vehicle exhaust pipe.

 

Keep children and unauthorised persons away from the working area.

 

DO NOT

 use the extractor for a task it was not designed to  

 

perform.

.

  

 

 

DO NOT

 operate the extractor if any parts are damaged or  

 

missing as this may cause failure or possible personal injury

 

DO NOT

 get the extractor wet or use in damp or wet locations  

 

or  areas where there is condensation.

 

DO NOT

 allow untrained persons to operate the extractor.

 

DO NOT

 operate the extractor when you are tired or under the  

 

influence of alcohol, drugs or intoxicating medication.

 

DO NOT

 use the extractor where there are flammable liquids,  

 

solids or gases such as paint solvents, etc.

 

DO NOT

 leave the extractor operating unattended.

 

When not in use switch the extractor off and disconnect  

 

from the power supply.  

Reviews: