background image

instructions for

Inverter generator 2000W 230v 

4-stroke engIne

model no: 

g2000I.v2

thank you for purchasing a sealey product. Manufactured to a high standard, this product will, if used according to these 

instructions, and properly maintained, give you years of trouble free performance.

IMPORTANT:

 PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE 

THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR 
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.

1.  safety  

 

‰

     

WarnIng!

 

ensure any Health & safety, government, or local authority regulations are adhered to when using this equipment. 

 

9

   familiarise yourself with the application and limitations, as well as the potential hazards, of the generator.

 

9

   maintain the generator in good condition (use an authorised service agent). replace or repair damaged parts. use genuine parts only.  

  unauthorised parts may be dangerous and will invalidate the warranty.

 

9

   this generator is designed and manufactured for specific applications. 

Do not 

attempt to modify the unit or use it for any application  

  for which it is not designed. if you have any questions regarding the application of the unit please contact your local sealey stockist.

 

‰

   WarnIng! Do not 

exceed the Wattage/Amperage capacity of the generator

.

 Add rated wattage of all devices intended for  

 

  connection at any one time, the total must not exceed rated wattage of generator (see specifications). 

 

‰

   WarnIng! 

Generator exhaust gases contain deadly carbon monoxide which must not be inhaled. Always allow sufficient ventilation.

 

‰

   WarnIng! 

if you decide to use an earth leakage circuit Breaker (also referred to as an rcd or Ground fault circuit interrupter),

        

it is imperative that the neutral end of the power winding is connected to the frame of the generator set and that the earth lug on the  

   

frame is connected with a low impedance connector to the local earth via an earth spike or local protective earth conductor. this    

   

connection should only be attempted by a qualified electrician, after first having consulted your local dealer.

 

   Danger! 

this generator is designed for outdoor use only. to use the generator inside any building or enclosure, including the 

          generator compartment of a caravan, may result in fire or an explosion. no user performed modifications, including venting of the    

   

exhaust and/or cooling ventilation, will eliminate the danger.

 

   Danger! 

 if this unit is used for back-up power in the event of a commercial power failure, the following steps must be taken.

          Before connecting the generator to the electrical system, open the main circuit breaker to isolate the generator and system from the  

   

commercial electric supply. failure to do this may result in damage to the generator and may result in serious injury or fatality, due to a  

   

back-feed of electrical energy.

 

   Danger! 

the generator produces a very powerful voltage that can cause a severe electrical shock. Avoid contact with bare wires,   

  terminals etc. never allow any unqualified person to operate or service the generator.

 

‰

   WarnIng! 

Petrol is highly flammable and petrol vapour is explosive. do not permit smoking, naked flames, sparks or heat in the    

  vicinity while handling petrol. Avoid spilling petrol onto a hot engine. comply with all laws regulating storage and handling of fuels.

 

‰

   WarnIng!

 risk of burns. 

Do not

 touch the exhaust system or the drive unit.

 

‰

  

WarnIng! never

 refuel when the engine is running or when the engine is hot. Allow cool down time.

 

9

  

operate the generator only on level surfaces (maximum allowable tilt is 10º) and where it will not be exposed to excessive moisture, dirt  

  or corrosive vapours or be in the proximity of combustible material (flammable liquids, solids or gases). 

 

8

 

  Do not

 tip or change the generator’s position whilst it is operating.

 

9

  

remove ill fitting clothing, ties, watches, rings and other loose jewellery and contain long hair. Wear appropriate protective clothing.

 

9

  

Keep non-essential persons and children away from the working area.

 

‰

   WarnIng!

 never start or stop the generator while electrical loads are connected. start the engine, let it stabilise, then connect the    

  electrical load. to stop engine, disconnect the electrical load and let engine stabilise before switching off.

 

‰

  

WarnIng! Do not

 use worn, bare, frayed or otherwise damaged electrical cables with the generator. to do so may result in electric  

 shock.

 

8

  

Do not

 use the generator for any purpose other than that for which it is designed. 

 

8

  

Do not

 operate the generator if any parts are missing or damaged, as this may cause failure and/or personal injury. 

 

8

  

Do not

 over-fill fuel tank. Always leave room for fuel to expand.

 

8

  

Do not

 operate in the rain.

 

  

Danger

Do not

 tamper with the engine governed speed setting. Higher operating speeds are dangerous and increase the risk    

  of personal injury and/or equipment damage. the generator supplies the correct rated frequencies and voltage only when running at the  

  correct governed speed. incorrect frequency and/or voltage can damage some connected electrical loads.  

 

 

 

  operating at excessively low speeds may result in shortened engine life. over-speeding will invalidate the warranty.

 

8

  

Do not

 operate the generator when you are tired, or under the influence of alcohol, drugs or intoxicating medication.

 

8

  

Do not

 store generator with fuel in tank where petrol vapours might reach an open flame or spark.

 

9

   the generator must be grounded with a good quality insulated conductor.

 

9

   Keep vents free from dirt etc.

 

9

   If supplying electronic equipment, or in an area where electronic equipment is being used, keep the generator a sufficient distance  

  away to prevent electrical noise from the engine.

G2000i.V2 | issue 1 05/09/16

Original Language Version

© Jack sealey limited

      refer to

   instructions

      electrical

        shock

       hazard

    Hot surfaces     do not cover     do not use in

non ventilated 

area

 switch off the engine

Before refuelling

Summary of Contents for G2000I.V2

Page 1: ... back feed of electrical energy DANGER The generator produces a very powerful voltage that can cause a severe electrical shock Avoid contact with bare wires terminals etc Never allow any unqualified person to operate or service the generator WARNING Petrol is highly flammable and petrol vapour is explosive Do not permit smoking naked flames sparks or heat in the vicinity while handling petrol Avoi...

Page 2: ...il is filled up If the engine stalls or does not start press the engine switch to ON and then pull the recoil starter it the oil warning light flickers for a few seconds there is insufficient oil add oil to restart 5 3 Overload Indicator Light Red The overload indicator light comes on when an overload of a connected electrical device is detected the inverter control unit overheats or the AC output...

Page 3: ... 5 8 Ground Earth terminal When the electrical device is earthed the generator must always be earthed 6 operation 6 1 Engine Oil WARNING The generator has been shipped without engine oil DO NOT start the engine until it has been filled with sufficient engine oil Recommended engine oil SAE SJ 15W 40 Recommended engine oil grade API Service SE type or higher Quantity 0 35ltr 6 1 1 Place the generato...

Page 4: ...is earthed 6 5 1 Start the engine 6 5 2 Turn the ECS to ON 6 5 3 Plug electrical device into the AC connection socket 6 5 4 Make sure the AC pilot light is on 6 5 5 Turn on the electrical device 6 5 6 If the generator is to be used to supply medical equipment obtain advice from manufacture medical professional 6 5 7 Some electrical appliances have high starting currents and therefore can not be us...

Page 5: ... 4 Install the spark plug 7 1 5 Install the spark plug cap and the spark plug cover Standard Spark Plug E6TC E6RTC Spark Plug Gap 0 6 0 7mm Spark Plug Torque 20 0 Nm 7 2 Carburettor Adjustment Adjusting the carburettor should be left to an authorised stockist with the professional knowledge specialised data and equipment to adjust to the correct settings 7 3 Engine Oil Replacement 7 3 1 Place the ...

Page 6: ...inity of an open flame 7 6 1 Remove the fuel tank cap and filter fig 23 7 6 2 Clean the filter with petrol in a wash tank 7 6 3 Wipe the filter and install it 7 6 4 Install the fuel tank cap Be sure the fuel tank cap is tightened securely 7 7 Fuel Filter 7 7 1 Remove the screws fig 24 1 and then remove cover fig 24 2 and drain the fuel fig 25 3 7 7 2 Hold and move up the clamp fig 25 4 and the tak...

Page 7: ...p the engine and restart Parts support is available for this product To obtain a parts listing and or diagram please log on to www sealey co uk email sales sealey co uk or telephone 01284 757500 NOTE It is our policy to continually improve products and as such we reserve the right to alter data specifications and component parts without prior notice IMPORTANT No liability is accepted for incorrect...

Reviews: