background image

INSTRUCTIONS FOR: 

GALVANIZED STEEL 

SHED 1.5 x 0.8 x 1.9m WITH SIDE DOOR.

MODEL NO:

 

GSS150819SDG

WARNING! 

Ensure Health & Safety, local authority, and general workshop practice regulations are adhered to when building this shed.

Keep the work area clean, uncluttered and ensure there is adequate lighting.

Keep children and unauthorised persons away from the working area.

DO NOT

 use the shed for any purpose other than that for which it is designed.

Use appropriate safety clothing including eye protection.

Note: 

The assembly of this product will require assistance.

DO NOT 

attempt to assemble in windy weather.

IMPORTANT:

 

PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS.  USE THE 

PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR PERSONAL 
INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.

Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, 
and properly maintained, give you years of trouble free performance.

1. SAFETY

2. INTRODUCTION

3. SPECIFICATION

Galvanized, steel panels easily assembled to form a rigid and secure shed. Has skillion (sloping) roof and single door. Door are secured by cross 

bolt and eyelet which will accept a padlock (not included) for additional security. Supplied with bolt-down fixing kit. 

Model No:  . . . . . . . . . . . . . . . . . . . . . . . . GSS150819SDG

Overall Size (W x D x H*):

  . . . . . . . .

1500 x 800 x 1900mm

Roof Type:  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Skillion

* Minimum wall height

  GSS150819SDG   Issue: 1 - 27/08/14

 © Jack Sealey Limited

Original Language Version

Summary of Contents for GSS150819SDG

Page 1: ...AUTIONS USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED FAILURE TO DO SO MAY CAUSE DAMAGE AND OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE Thank you for purchasing a Sealey product Manufactured to a high standard this product will if used according to these instructions and properly maintained give you years of tro...

Page 2: ...embrane and a suitable reinforcing mesh We recommend that you make your slab 100mm bigger than the base dimensions of your shed This will allow for a 50mm edge around your shed We recommend that you slope the 50mm edges downward by 10mm so that rain water will drain away from your shed 4 CONCRETE PLINTH SLAB 5 TOOLS REQUIRED GSS150819SDG Issue 1 27 08 14 Jack Sealey Limited Original Language Versi...

Page 3: ... 1780 x 720 channel 1508 Check contents Lay out all components with the part numbers facing upwards and check off against the parts lists on the next four pages In the unlikely event of a missing component please contact you local Sealey dealer 6 CONTENTS GSS150819SDG Issue 1 27 08 14 Jack Sealey Limited Original Language Version ...

Page 4: ... bracket Part No 72 6 1 Please note some component descriptions may differ in manual text to listings always use pictures from listings to double check component identity ie M8 fixings may be supplied in lieu of 5 16 GSS150819SDG Issue 1 27 08 14 Jack Sealey Limited Original Language Version ...

Page 5: ...7 PARTS DIAGRAM GSS150819SDG Issue 1 27 08 14 Jack Sealey Limited Original Language Version ...

Page 6: ...n your work table and join them together with the 10mm long self tapping screws See the pre punched holes and both diagrams 8 1 3 Fit top and bottom channels 20B and 20C to panels by firstly sliding and finally tapping into place as indicated by arrows in the diagrams Note that the smaller flange on the channels should always be adjacent to the out side face of the panel this prevents rainwater en...

Page 7: ...n it by the pre punched holes and 10mm long self tapping screws Note this channel is fitted with the flat face uppermost 8 1 5 With self tapping screws fix items 20B and 20C to top and bottom edges GSS150819SDG Issue 1 27 08 14 Jack Sealey Limited Original Language Version ...

Page 8: ...the top face in both diagrams 8 2 3 Fit item 32D the mid height wall channel to the panel and position it by the pre punched holes and 10mm long self tapping screws Note this channel is fitted with the flat face uppermost ie nearest the top 8 2 4 With self tapping screws fix item 21B to bottom edge but do not screw fix item 21A to top edge at this stage see places marked with asterisk 8 2 ASSEMBLE...

Page 9: ... channels 20B and 20C to panels by firstly sliding and finally tapping into place Note that the smaller flange on the channels should always be adjacent to the outside face of the panel The outside face is the diagram Fix both with 10mm long self tapping screws except for positions marked with asterisk which are not fixed at this stage GSS150819SDG Issue 1 27 08 14 Jack Sealey Limited Original Lan...

Page 10: ...nnel to the panel and position it by the pre punched holes and 10mm long self tapping screws Note this channel is fitted with the flat face uppermost ie nearest the top GSS150819SDG Issue 1 27 08 14 Jack Sealey Limited Original Language Version ...

Page 11: ...bottom channels item 20A to panels by firstly sliding and finally tapping into place as previously explained in 8 1 3 Note that the smaller flange on the channels should always be adjacent to the outside face of the panel The outside face is the top face in both diagrams 8 4 ASSEMBLE THE ROOF PANEL GSS150819SDG Issue 1 27 08 14 Jack Sealey Limited Original Language Version ...

Page 12: ...4 3 Fit item 50 angles to each edge refer to diagram this page for flange orientation Fix with 10mm long self tapping screws 50 GSS150819SDG Issue 1 27 08 14 Jack Sealey Limited Original Language Version ...

Page 13: ...E AND FRONT PANELS TOGETHER 8 5 1 Attach the side wall 2E to the rear wall 1A 1L then the front wall 9A 9S Fix all walls with the 10mm long self tapping screws GSS150819SDG Issue 1 27 08 14 Jack Sealey Limited Original Language Version ...

Page 14: ...oor mullion sections are fixed with 16mm long self tapping screws Do not fix self tapping screws marked in enlarged ballooned views at this stage FIX DOOR MULLION SECTIONS WITH SIX 16mm LONG SELF TAPPING SCREWS GSS150819SDG Issue 1 27 08 14 Jack Sealey Limited Original Language Version ...

Page 15: ... fix with 16mm long self tapping screws Fix the channel item 21H with 16mm long self tapping screws 8 6 3 Slide and tap on top channel item 21J but do not screw fix at this stage GSS150819SDG Issue 1 27 08 14 Jack Sealey Limited Original Language Version ...

Page 16: ... pre punched holes with 4mm diameter rivets Check action of door before crimping rivets 8 7 2 Fit the shoot bolt item 70 and the bolt keeper item 71 and fix with 10mm long self tapping screws or 4mm diameter rivets fitting method A or B GSS150819SDG Issue 1 27 08 14 Jack Sealey Limited Original Language Version ...

Page 17: ...ix to internal compartment This will require spotting and drilling 8mm diameter holes through to shed panels Spot through holes to plinth slab remove anchor angles and masonry drill slab for anchor bolts Please note anchor bolts and M8 machine screws are supplied see FITTINGS PACK 8 8 3 Insert anchor bolts re fit steel angles and anchor shed to plinth slab GSS150819SDG Issue 1 27 08 14 Jack Sealey...

Page 18: ...y Limited Environmental Protection Recycle unwanted materials instead of disposing of them as waste All tools accessories and packaging should be sorted taken to a recycling centre and disposed of in a manner which is compatible with the environment When the product becomes completely unserviceable and requires disposal drain off any fluids if applicable into approved containers and dispose of the...