background image

InstructIons for:

ENERGY SAVING WORK LAMPS 36W

Model no's:

 

ML36, ML36T, ML36TD

thank you for purchasing a sealey product. Manufactured to a high standard this product will, if used according to these instructions and properly 

maintained, give you years of trouble free performance.

IMPORTANT:

 

PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. 

USE  THE  PRODUCT  CORRECTLY  AND  WITH  CARE  FOR  THE  PURPOSE  FOR  WHICH  IT  IS  INTENDED.  FAILURE  TO  DO  SO  MAY  CAUSE 

DAMAGE  AND/OR  PERSONAL  INJURY AND/OR  WILL  INVALIDATE  THE  WARRANTY.  PLEASE  KEEP  INSTRUCTIONS  SAFE  FOR  FUTURE  USE.

1.1 .

 

ELECTRICAL SAFETY

 

 

  WARNING!

 It is the responsibility of the owner and the operator to read, understand and comply with the following:

   

You must check all electrical products, before use, to ensure that they are safe. You must inspect power cables, plugs, sockets and    

   

any other connectors for wear or damage. You must ensure that the risk of electric shock is minimised by the installation of  

 

   

appropriate safety devices. A residual current circuit Breaker (rccB) should be incorporated in the main distribution board. We also  

   

recommend that a residual current device (rcd) is used. It is particularly important to use an rcd with portable products that are    

   

plugged into a supply which is not protected by an rccB. If in any doubt consult a qualified electrician. You may obtain a residual    

   

current device by contacting your sealey dealer. 

   

You must also read and understand the following instructions concerning electrical safety.

1.1.1.  the electricity at Work Act 1989 requires that all portable electrical appliances, if used on business premises, are tested by a qualified  

 

electrician, using a Portable Appliance tester (PAt), at least once a year.

1.1.2.  the Health & safety at Work Act 1974 makes owners of electrical appliances responsible for the safe condition of those appliances    

 

and the safety of the appliance operators. If in any doubt about electrical safety, contact a qualified electrician.

1.1.3.  ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply. see 1.1.1. and 1.1.2.    

 

and use a Portable Appliance tester.

1.1.4.  ensure that cables are always protected against short circuit and overload.

1.1.5.  regularly inspect power supply cables and plugs for wear or damage and check all 

 

connections to ensure that none are loose.

1.1.6.  Important: ensure that the voltage marked on the appliance matches the power supply 

 

to be used and that the plug is fitted with the correct fuse - see fuse rating at right.

1.1.7.  do not pull or carry the appliance by the power cable.

1.1.8.  do not pull the plug from the socket by the cable.

1.1.9.  do not use worn or damaged cables, plugs or connectors. Immediately have any faulty 

 

item repaired or replaced by a qualified electrician. When a Bs 1363/A uK 3 pin plug is  

 

damaged, cut the cable just above the plug and dispose of the plug safely. 

 

fit a new plug according to the following instructions (uK only).

 

a) Connect the GREEN/YELLOW earth wire to the earth terminal ‘E’.

 

b) Connect the BROWN live wire to the live terminal ‘L’.

 

c) Connect the BLUE neutral wire to the neutral terminal ‘N’.

 

d) After wiring, check that there are no bare wires, that all wires have been correctly connected, that the cable outer  

 

 

insulation extends beyond the cable restraint and that the restraint is tight.

 

double insulated products, which are always marked with this symbol    , are fitted with live (brown) and neutral (blue) wires only. 

 

to rewire, connect the wires as indicated above do not connect either wire to the earth terminal.

1.1.10.  Products which require more than 13 amps are supplied without a plug. In this case you must contact a qualified electrician to ensure  

 

that a suitably rated supply is available. We recommend that you discuss the installation of an industrial round pin plug and socket    

 

with your electrician.

1.1.11.  If an extension reel is used it should be fully unwound before connection. A reel with an rcd fitted is preferred since any appliance    

 

plugged into it will be protected. the cable core section is important and should be at least 1.5mm

²

, but to be absolutely sure that the  

 

capacity of the reel is suitable for this product and for others which may be used in the other output sockets, we recommend the use   

 

of 2.5mm

²

 section cable.

1.  SAFETY INSTRUCTIONS

FUSE RATING

 

5 AMP

Blue 

Neutral 

Wire

Yellow & Green 

Earth Wire 

Cable 

Restraint

Brown

Live 

Wire

1.2. 

GENERAL SAFETY

 

  

WARNING!

 

Ensure Health & Safety, local authority, and general workshop practice regulations are adhered to when using this  

 

 

lamp.

 

do not immerse lamp in water.

 

ensure the lamp is disconnected from the mains before attempting to change the fluorescent tube.

 

Maintain the

 

lamp in good condition (use an authorised service agent).

 

ensure there are no flammable liquids or vapours present. 

 

DO NOT 

use lamp for any purpose other than that for which it is designed.

 

DO NOT

 pull the cord to remove the plug from the power supply.

 

When not in use unplug from the mains power supply and store in a safe, dry, childproof area.

2.  INTRODUCTION

fitted with a compact fluorescent energy saving bulb, which emits a bright white light. low wattage means a low energy consumption which helps 

to reduce energy bills. lighting brackets feature angle adjustment. 

ML36 - 

Mounted on a floor standing bracket, which features angle adjustment. Incorporates pre-drilled holes for optional wall mounting. 

ML36T - 

Mounted on a two-position telescopic tripod with folding legs and cable storage hooks.

ML36TD - 

removable head allows use as free-standing or can be mounted on a telescopic tripod stand.  

stand features two-position telescopic uprights with folding legs and cable storage hooks. suitable for lighting workshops, garages and any other 

environment where light is limited. supplied with 3mtr lead and Bs approved plug.

MODEL No's . . . . . . . .ML36  . . . . . . . . . . . . . . ML36T . . . . . . . . . . . . . ML36TD

Power . . . . . . . . . . . . . .36W . . . . . . . . . . . . . . . 36W . . . . . . . . . . . . . . . 2x36W

supply. . . . . . . . . . . . . .230V. . . . . . . . . . . . . . . 230V. . . . . . . . . . . . . . . 230V

Min/Max Height  . . . . . .n/a  . . . . . . . . . . . . . . . . 900 / 1500mm . . . . . . . 900 / 1500mm

Bulb fitting . . . . . . . . . .e27 screw cap  . . . . . . e27 screw cap . . . . . . e27 screw cap

replacment Bulb  . . . . .Ml36B . . . . . . . . . . . . . Ml36B . . . . . . . . . . . . . Ml36B

Original Language Version

Ml36, Ml36t, Ml36t   Issue: 1 - 20/05/10

Reviews: