background image

INSTRUCTIONS FOR:

HEAVY DUTY TELESCOPIC 

WORK LIGHTS 

MODEL No:

 

MLS500, MLT500

Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions and 

properly maintained, give you years of trouble free performance.

  1.  SAFETY INSTRUCTIONS

IMPORTANT

PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS, AND 

CAUTIONS. USE THIS PRODUCT CORRECTLY, AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO 

MAY CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY.

1.1 

ELECTRICAL SAFETY

  

WARNING!

 It is the responsibility of the owner and the operator to read, understand and comply with the following:

  You must check all electrical products, before use, to ensure that they are safe. You must inspect power cables, plugs, sockets and  

 

  any other connectors for wear or damage. You must ensure that the risk of electric shock is minimised by the installation of  

 

 

  appropriate safety devices. A Residual Current Circuit Breaker (RCCB) should be incorporated in the main distribution board. We also  

 

  recommend that a Residual Current Device (RCD) is used. It is particularly important to use an RCD with portable products that are  

 

  plugged into a supply which is not protected by an RCCB. If in any doubt consult a qualified electrician. You may obtain a Residual  

 

  Current Device by contacting your Sealey dealer. 

  You must

 also read and understand the following instructions concerning electrical safety.

1.1.1  The 

Electricity at Work Act 1989 

requires all portable electrical appliances, if used on business premises, to be tested by a qualified  

 

electrician, using a Portable Appliance Tester (PAT), at least once a year.

1.1.2  The 

Health & Safety at Work Act 1974 

makes owners of electrical appliances responsible for the safe condition of those appliances  

 

and the safety of the appliance operators. 

If in any doubt about electrical safety, contact a qualified electrician.

1.1.3  Ensure that the insulation on all cables and on the appliance is safe before connecting it to   the power supply. See 1.1.1. and 1.1.2.   

 

and use a Portable Appliance Tester.

1.1.4  Ensure that cables are always protected against short circuit and overload.

1.1.5  Regularly inspect power supply cables and plugs for wear or damage and check all

 

connections to ensure that none is loose.

1.1.6 

Important:

 Ensure that the voltage marked on the appliance matches the power supply 

 

to be used and that the plug is fitted with the correct fuse - see fuse rating at right.

1.1.7 

DO NOT

 pull or carry the appliance by the power cable.

1.1.8 

DO NOT 

pull the plug from the socket by the cable.

1.1.9 

DO NOT

 use worn or damaged cables, plugs or connectors. Immediately have any faulty 

 

item repaired or replaced by a qualified electrician. When an ASTA/BS approved UK 

 

3 pin plug is damaged, cut the cable just above the plug and 

dispose of the plug safely. 

 

Fit a new plug according to the following instructions (UK only).

 

a)  Connect the GREEN/YELLOW earth wire to the earth terminal ‘E’.

 

b)  Connect the BROWN live wire to the live terminal ‘L’.

 

c)  Connect the BLUE neutral wire to the neutral terminal ‘N’.

 

d)  After wiring, check that there are no bare wires, that all wires have been correctly  

 

connected, that the cable outer insulation extends beyond the cable restraint and that the restraint is tight.

 

Double insulated products, which are always marked with this symbol      , are fitted with live (brown) and neutral (blue) wires only.    

 

To rewire, connect the wires as indicated above - 

DO NOT

 connect either wire to the earth terminal.

1.1.10  Products which require more than 13 amps are supplied without a plug. In this case you must contact a qualified electrician to ensure  

 

that a suitably rated supply is available. We recommend that you discuss the installation of an industrial round pin plug and socket    

 

with your electrician.

1.1.11  If an extension reel is used it should be fully unwound before connection. A reel with an RCD fitted is preferred since any appliance    

 

plugged into it will be protected. The cable core section is important and should be at least 1.5mm², but to be absolutely sure that the  

 

capacity of the reel is suitable for this product and for others which may be used in the other output sockets, we recommend the use   

 

of 2.5mm² section cable. If extension reel is to be used outdoors, ensure it is marked for outdoor use.

1.2 

GENERAL SAFETY

 

Disconnect lamp from the mains power before changing accessories, servicing or performing any maintenance.

 

Maintain the

 

lamp in good condition (Repairs must only be undertaken by a qualified electrician, use an authorised service agent).

  Replace or repair damaged parts. 

Use recommended parts only, unauthorised parts may be dangerous and will invalidate the warranty.

  Lamp becomes very hot. Stand the lamp at least 1 metre from flammable or combustible materials such as wood, cloth, paper etc.

  Keep children and unauthorised persons away from the lamp.

  If you use an extension lead the cable must be fully unwound from the drum and laid as straight as possible.

  The lamps are weatherproof and may be used out of door, ensure any extensions and plugs are weather compatible. 

 

DO NOT handle halogen bulbs as the natural oil from your fingers and hands will shorten the bulb life. Handle only with a soft cloth.

 

DO NOT allow children to operate the unit.

 

DO NOT use the lamp near flammable, combustible or explosive liquids, solids, gases or equipment.

 

DO NOT touch the light when operating, allow to cool before touching, lamp operates at high temperature.

 

WARNING!

 DO NOT direct the lamp light into a person’s eyes.

 

DO NOT use the lamp for any purpose other than for which it is designed.

  When not in use switch the lamp off, remove plug from the power supply, ensure the unit is dry then store in a safe, dry, childproof area. 

FUSE RATING

 

3 AMP

Blue 

Neutral 

Wire

Yellow & Green 

Earth Wire 

Cable 

Restraint

Brown

Live 

Wire

Original Language Version

MLS500, MLT500    Issue: 2 - 22/10/09

Reviews: