background image

InstructIons for: 

COIL SPRING COMPRESSOR -
AIR OPERATED 1000KG 

Model no:

 

RE300

thank you for purchasing a sealey product. Manufactured to a high standard this product will, if used according to these instructions 
and properly maintained, give you years of trouble free performance.

IMPORTANT:

 

PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. 

USE  THE  PRODUCT  CORRECTLY  AND  WITH  CARE  FOR  THE  PURPOSE  FOR  WHICH  IT  IS  INTENDED.  FAILURE  TO  DO  SO  MAY  CAUSE 
DAMAGE  AND/OR  PERSONAL  INJURY  AND  WILL  INVALIDATE  THE  WARRANTY.  PLEASE  KEEP  INSTRUCTIONS  SAFE  FOR  FUTURE  USE.

 

GENERAL SAFETY.

 

WARNING!

 

Ensure Health & Safety, local authority, and general workshop practice regulations are adhered to when using   

 

this equipment.

 

WARNING!

 

Wear approved safety hand and eye protection (standard spectacles are not adequate).

 

WARNING! TRAPPING DANGER

 – Keep hands and fingers away from the spring and compressing jaws in use. 

 

Keep the work area clean, uncluttered and ensure there is adequate lighting.

 

Maintain correct balance and footing. ensure the floor is not slippery and wear non-slip shoes.

 

remove ill-fitting clothes. remove ties, watches, rings, other loose jewellery. contain and/or tie back long hair.

 

Wear appropriate protective clothing. 

 

familiarise yourself with the applications, limitations and potential hazards of the spring compressor.

 

DO NOT

 force the spring compressor to achieve a task it was not designed to perform.

 

DO NOT

 allow untrained persons to use the spring compressor.

 

PRE-OPERATIONAL SAFETY.

 

Apply grease to the front and rear faces of the main upright to assist the smooth action of the compressor. 

 

DO NOT

 operate compressor if parts are damaged or missing as this may cause failure and/or personal injury.

 

Before commencing compression, make visual inspection of machine to ensure pins are securely positioned and that  

 

 

there is no sign of wear or fatigue – if found, do not use and refer to your local sealey dealer for advice and  replacement parts.

 

ensure jaw locating pins are properly positioned and safety clips are attached correctly. 

 

Before commencing compression of spring, ensure coils of the spring are seated securely in the jaws of the compressor and    

 

cannot slide out during compression. 

 

ALWAYS ensure that the safety guard locks in place, and also use the chain to secure the spring safely.

 

OPERATIONAL SAFETY.

 

When applying compression to the spring, always stand to one side of the compressor.

 

DANGER! Stop compressing the spring before the coils touch. 

 

Before attempting to remove top cap nut, always use a tool or similar to test if the compression has been relieved, 

Do not

 use   

 

your hands / fingers.

 

We recommend the use of purpose made strut tools to remove the top-nut from the shock piston. 

 

once compressed, and the strut removed, we recommend releasing the tension on the spring. do not leave the spring  

 

 

under compression in the machine unattended and do not leave in compression for prolonged periods, i.e. overnight. 

 

Before releasing the compression ensure that the top strut-nut is securely tightened to the manufacturer's tolerance. 

 

release the compression slowly keeping your hands and fingers away from the spring assembly. 

 

Be sure that the tension on the spring is fully controlled by the strut assembly before removing it from the jaws of the 

 

compressor.

 

POST OPERATIONAL SAFETY.

 

When not in use, clean and store the spring compressor in a safe, dry, childproof location.

 

Maintain the

 

spring compressor in good condition. replace or repair damaged parts. 

Use genuine parts only.

 

Unauthorised parts may be dangerous and will invalidate the warranty.

1.  SAFETY INSTRUCTIONS

  3.  TECHNICAL SPECIFICATION

Maximum load: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1000kg
upper Yoke travel: . . . . . . . . . . . . . . . . . . . . . . . . . . . . 420mm
spring diameters:  . . . . . . . . . . . . . . . . . . . . . . . . . 102-165mm
Actuation: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .foot Pedal
Maximum Air Pressure:  . . . . . . . . . . . . . . . . . . . . 116psi (8bar)

fast and safe compression of road springs. 1000kg Air operated unit with safety locking guard. supplied with two 
interchangeable plastic coated lower yokes and a suspension strut clamp. fits a wide range of spring configurations and 
diameters. Also features a strut locating platform for easy movement of the suspension strut to avoid unnecessary lifting.

  2.  INTRODUCTION 

Original Language Version

re300             Issue: 1 - 30/11/09

 

unpack the spring compressor carefully, it will be necessary for two people to do this.

4.1.

 

Assemble the spring compressor as follows:

4.1.1.  lay out all of the parts ready for assembly.
4.1.2.  fit the two feet to the bottom of the frame with the wheels facing rearwards. use four allen bolts, flat washers, spring    
 

washers and domed nuts, to secure in place. 

 

NOTE:

 the one longer bolt is fitted in position as shown in fig.1.   

4.1.3.  using two people, stand the unit onto it's feet, taking care when the wheels come into contact with the floor as the unit's  
 

weight might become unstable.

  4.  ASSEMBLY & PREPARATION

Summary of Contents for Professional Tools AUTO SERVICE LINE RE300

Page 1: ...o use the chain to secure the spring safely OPERATIONAL SAFETY When applying compression to the spring always stand to one side of the compressor DANGER Stop compressing the spring before the coils touch Before attempting to remove top cap nut always use a tool or similar to test if the compression has been relieved Do not use your hands fingers We recommend the use of purpose made strut tools to ...

Page 2: ...the handle to the top of the unit using two domed nuts spring washers and washers to secure in place 4 1 9 There are pre drilled holes in the feet if the unit needs to be bolted to the floor permanently 4 1 10 Hang two of the brackets attachments to the sides of the frame and locate the third bracket onto the compressor using the locking pin to hold it in position fig 7 4 1 11 Position the unit in...

Page 3: ...correctly in the jaws it is possible that the strut top retaining cap could be subject to sideways forces Watch closely as the spring reaches it s final phase of compression and ensure the top cap assembly rotates freely before attempting to remove it 5 1 8 When the strut is loose within the spring unscrew the strut locking plate nut and remove the locking plate from the top of the strut gradually...

Page 4: ... other maintenance required should be carried out by an authorised service agent 6 4 If the Spring Compressor is not being used for a considerable length of time disconnect the air supply and discharge any air in the cylinder by depressing the foot control lever Drop a little Sealey air tool oil into the air inlet and cover to prevent the ingress of any foreign matter 6 MAINTENANCE WARNING Keep ha...

Reviews: