INSTRUCTIONS FOR:

PREMIER LINE COMPRESSORS

Models

SA2110/3, SA2115/3 

& SA2120/3

Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions 

and properly maintained, give you years of trouble free performance.

SA2110/3, SA2115/3 & SA2120/3 - 1069 - (2) - 150200

IMPORTANT:

PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS AND

CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY

CAUSE DAMAGE OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. PLEASE KEEP INSTRUCTIONS SAFE FOR FUTURE USE.

1.2. 

GENERAL SAFETY INSTRUCTIONS

Familiarise yourself with the application and limitations of the compressor. 

Ensure the compressor is in good order and condition before use. If in any doubt do not use the unit and contact an electrician/service agent.

p

WARNING! 

Compressor must only be serviced by an authorised agent. DO NOT tamper with, or attempt to adjust,  pressure switch or safety valve.

Before moving, or maintaining the compressor ensure it is unplugged from the mains supply and that the air tank pressure has been vented. 

Only use recommended attachments and parts. To use non-recommended items may be dangerous and will invalidate your warranty.

Read the instructions regarding any accessory used with the compressor. Ensure the safe working pressure of any air appliance used exceeds

the compressors output pressure. If using a spray gun, check the area selected for spraying is provided with air change system/ventilation.

Ensure the air supply valve is turned off before disconnecting the air supply hose.

To move the compressor use the handle only.  Lift the compressor so that the front leg gives enough clearance for manoeuvring but maintain

unit’s centre of gravity in front of the wheels. DO NOT attempt to lift or move the compressor by any means other than by handle. 

Use the compressor in a well ventilated area and ensure it is placed on a firm surface.

Keep tools and other items away from the compressor when it is in use and keep area clean and clear of unnecessary items.

Ensure the air hose is not tangled, twisted or pinched.

Keep children and unauthorised persons away from the working area.

DO NOT dis-assemble compressor for any reason. The unit must be checked by qualified personnel only.

DO NOT use the compressor outdoors, or in damp, or wet, locations and DO NOT operate within the vicinity of flammable liquids, gases or solids.

DO NOT touch compressor cylinder, cylinder head or pipe from head to tank as these may be hot and will remain so for some time after shutdown.

DO NOT attempt to move the compressor by pulling the air tool hose. Only move the compressor by its handle.

DO NOT use this product to perform a task for which it has not been designed.

DO NOT deface the certification plate attached to the end of the compressor tank.

DO NOT cover the compressor or restrict air flow around the machine whilst operating.

1. SAFETY INSTRUCTIONS

1.1.

ELECTRICAL SAFETY. 

WARNING! 

It is the user’s responsibility to read, understand and comply with the following:

You must check all electrical equipment and appliances to ensure they are safe before using. You must inspect power supply leads, plugs and

all electrical connections for wear or damage. You must ensure the risk of electric shock is minimised by the installation of appropriate safety

devices. An RCCB (Residual Current Circuit Breaker) should be incorporated in the main distribution board. We also recommend that an RCD

(Residual Current Device) is used with all electrical products. It is particularly important to use an RCD with portable products that are plugged

into an electrical supply not protected by an RCCB. If in doubt consult a professional electrician. You may obtain a Residual Current Device by

contacting your Sealey dealer. 

You must

also read and understand the following instructions concerning electrical safety.

1.1.1. The 

Electricity At Work Act 1989

requires all portable electrical appliances, if used on business premises, to be tested by 

a qualified electrician, at least once a year, using a Portable Appliance Tester (PAT).

1.1.2. The 

Health & Safety at Work Act 1974

makes owners of electrical appliances responsible for the safe condition of those appliances, 

and the safety of appliance operators. 

If in any doubt about electrical safety, contact a qualified electrician.

1.1.3. Ensure the insulation on all cables and the product itself is safe before connecting to the mains power supply. 

See 1.1.1. & 1.1.2. above and use a Portable Appliance Tester (PAT).

1.1.4. Ensure that cables are always protected against short circuit and overload.

1.1.5. Regularly inspect power supply leads and plugs for wear or damage and connections to ensure that none is loose. 

1.1.6.

Important:

Ensure the voltage marked on the product is the same as the electrical power supply

to be used, and check that plugs are fitted with the correct capacity fuse. 

1.1.7. DO NOT pull or carry the powered appliance by its power supply lead. 

1.1.8. DO NOT pull power plugs from sockets by the power cable.

1.1.9. DO NOT use worn or damage leads, plugs or connections. Immediately replace or have repaired by a qualified electrician. 
1.1.10.

NOTE: THIS PRODUCT IS INTENDED FOR USE ON AN INDUSTRIAL 30AMP SUPPLY WHICH MUST BE INSTALLED BY A QUALIFIED

ELECTRICIAN.

It may be possible to operate the compressor on a “Domestic” 13Amp outlet under the following conditions: The mains supply

must conform to IEE Wiring Regulations, and the “spur” used to run the compressor must not include any other socket which could be used for 

another appliance. The distance of the socket from the mains distribution point must not exceed 5 metres.

An 

extension lead 

must not be used

.

1.1.11.

Note: 

Under certain conditions your compressor will draw more than 13Amps. Consequently, 

we recommend a 30Amp supply and suggest that a direct round pin plug/socket is installed by 

a qualified electrician. In the event that you choose to use a domestic 13Amp supply, 

we provide the plug wiring instructions as follows:

(UK only - see diagram at right). Ensure the unit is correctly earthed via a three-pin plug. 

a) Connect the green/yellow earth wire to the earth terminal ‘E’.

b) Connect the brown live wire to the live terminal ‘L’.

c) Connect the blue neutral wire to the neutral terminal ‘N’.

Ensure the plug is fitted with a 13Amp fuse.

After wiring, check there are no bare wires, that all wires have been correctly

connected, that the cable outer insulation extends past the cable restraint and that the cable restraint is tight. 

NOTE: 

IF USED ON A DOMESTIC 13AMP SUPPLY AND THE FUSE REPEATEDLY BLOWS, CONTACT A QUALIFIED

ELECTRICIAN TO INSTALL A 30AMP SUPPLY.

Blue

Neutra

l

 

Yellow & Green 

Earth wire 

Cable 

restrai

Brown

Live 

wire

Summary of Contents for SA2110/3

Page 1: ...ctions for wear or damage You must ensure the risk of electric shock is minimised by the installation of appropriate safety devices An RCCB Residual Current Circuit Breaker should be incorporated in the main distribution board We also recommend that an RCD Residual Current Device is used with all electrical products It is particularly important to use an RCD with portable products that are plugged...

Page 2: ...ed 3 6 Confirm that the oil level is at the maximum mark on the sight glass fig 3 fig 1 Free Air Delivery cfm Model Max Motor Output hp Voltage Phase Current A Pump Type Pump Speed rpm Piston Displacement cfm At 2 5 Bar Max At 6 0 Bar Tank Capacity l Max Pressure psi bar Noise Level dB A SA2110 3 3 230 1 13 K17 1180 14 9 11 6 12 0 10 6 100 145 10 73 SA2115 3 3 230 1 13 K17 1180 14 9 11 6 12 0 10 6...

Page 3: ...quipped with an overload cut out to protect the motor The manual reset D fig 6 should not be operated until 3 minutes after cut out to allow the motor to cool To restart turn main switch off reset D and then turn main switch on If after restarting the compressor again automatically cuts out turn off at the main switch and contact Service Agent 4 6 SA2110 3 The output pressure is regulated by the p...

Page 4: ...oil level Clean intake filter Check belt tension Check condition of belt and pulleys Check tube fittings and electrical connections Replace oil General cleaning of compressor Internal external inspection of tank Replace air filter Check tank for internal corrosion Check for oil leaks SA2110 3 SA2115 3 SA2120 3 1069 2 150200 6 TROUBLE SHOOTING 5 8 Recommended oils Recommended oil for compressors su...