background image

InstructIons for:

COMPRESSOR 50ltr 

diRECt dRivE 3.0hp

 

model no:

 

SAC5030vE

thank you for purchasing a sealey product. manufactured to a high standard this product will, if used according to these instructions and properly 

maintained, give you years of trouble free performance.

1.  SAFEtY iNStRUCtiONS

IMPORTANT:

 

PLEASE REAd tHESE iNStRUCtiONS CAREFULLY. NOtE tHE SAFE OPERAtiONAL REQUiREMENtS, WARNiNGS & CAUtiONS. USE 

tHE PROdUCt CORRECtLY ANd WitH CARE FOR tHE PURPOSE FOR WHiCH it iS iNtENdEd. FAiLURE tO dO SO MAY CAUSE dAMAGE OR 

PERSONAL iNJURY ANd WiLL iNvALidAtE tHE WARRANtY. PLEASE KEEP iNStRUCtiONS SAFE FOR FUtURE USE.

sAc5030Ve     Issue no: 3 - 25/06/12

 

  We recommend that you discuss the installation of an  

 

 

  industrial round pin plug and socket with your electrician.

 

  

 

iMPORtANt!

  the use of extension leads to connect these   

 

  compressors to the mains is not recommended as the  

 

 

  resulting voltage drop reduces motor, and therefore pump    

 

  performance.

1.2.    GENERAL SAFEtY 

3  

 

familiarise yourself with the application and limitations of the  

 

  compressor.   

 

3  

 

ensure the compressor is in good order and condition before  

 

  use. If in any doubt do not use the unit and contact an  

 

 

  electrician/service agent.

  

  WARNiNG! 

Compressor must only be serviced by an    

 

  authorised agent. DO NOT tamper with, or attempt to    

 

  adjust, pressure switch or safety valve.

3  

 

Before moving, or maintaining the compressor ensure it is    

 

  unplugged from the mains supply and that the air tank  

 

 

  pressure has been vented. 

3  

 

maintain the compressor in good condition and replace any   

 

  damaged or worn parts. use genuine parts only.    

 

 

 

Unauthorised parts may be dangerous and will invalidate    

 

  your warranty.

3  

 

read the instructions relating to any accessory to be used    

 

  with this compressor. ensure the safe working pressure of    

 

  any air appliance used exceeds compressors output  

 

 

  pressure. If using a spray a gun, check that the area selected  

 

  for spraying is provided with an air change/ventilation system.

3  

 

ensure the air supply valve is turned off before disconnecting  

 

  the air supply hose.

3  

 

to move the compressor use the handle only. maintain unit’s  

 

  centre of gravity when lifting. 

dO NOt

 attempt to lift or move  

 

  the compressor by any other means. 

3  

 

use the compressor in a well ventilated area and ensure it is  

 

  placed on a firm surface.

3  

 

Keep tools and other items away from the compressor when  

 

  it is in use, and keep area clean and clear of unnecessary    

 

  items.

3  

 

ensure the air hose is not tangled, twisted or pinched.

1.1.  ELECtRiCAL SAFEtY

  

WARNiNG!

 It is the responsibility of the owner and the operator to 

read, understand and comply with the following: You must check all 

electrical products, before use, to ensure that they are safe. You must 

inspect power cables, plugs, sockets and any other connectors for wear 

or damage. You must ensure that the risk of electric shock is minimised 

by the installation of appropriate safety devices. A residual current 

circuit Breaker (rccB) should be incorporated in the main distribution 

board. We also recommend that a residual current device (rcd) is 

used. It is particularly important to use an rcd with portable products 

that are plugged into a supply which is not protected by an rccB. If in 

any doubt consult a qualified electrician. You may obtain a residual 

current device by contacting your sealey dealer. You must also read 

and understand the following instructions concerning electrical safety.

1.1.1. the 

Electricity at Work Act 1989

 requires that all portable  

 

    electrical appliances, if used on business premises, are tested    

    by a qualified electrician, using a Portable Appliance tester  

 

    (PAt), at least once a year.

1.1.2. the 

Health & Safety at Work Act 1974

 makes owners of  

 

    electrical appliances responsible for the safe condition of those   

    appliances and the safety of the appliance operators. 

if in any    

    doubt about electrical safety, contact a qualified electrician.

1.1.3. ensure that the insulation on all cables and on the appliance is   

    safe before connecting it to the power supply. see 1.1.1. and    

    1.1.2. and use a Portable Appliance tester.

1.1.4. ensure that cables are always protected against short circuit    

    and overload.

1.1.5. regularly inspect power supply cables and plugs for wear or    

    damage and check all connections to ensure that none is loose.

1.1.6. 

important:

 ensure that the voltage marked on the appliance    

    matches the power supply to be used and that the plug is fitted   

    with the correct fuse - see fuse rating below.

1.1.7. 

dO NOt

 pull or carry the appliance by the power cable.

1.1.8. 

dO NOt

 pull the plug from the socket by the cable.

1.1.9. 

dO NOt

 use worn or damaged cables, plugs or connectors.    

    Immediately have any faulty item repaired or replaced by a  

 

    qualified electrician. When a Bs 1363/A uK 3 pin plug is  

 

    damaged, cut the cable just above the plug and dispose of the    

    plug safely. 

    fit a new plug according to the following instructions (uK only).

    a) Connect the GREEN/YELLOW earth wire to the earth  

 

    terminal ‘E’.

    b) Connect the BROWN live wire to the live terminal ‘L’.

    c) Connect the BLUE neutral wire to the neutral terminal ‘N’.

    d) After wiring, check that there are no bare wires, that 

    all wires have been correctly connected, that the cable outer  

    insulation extends beyond the   

    cable restraint and that the  

 

    restraint is tight.

    double insulated products, which   

    are always marked with this  

 

    symbol    , are fitted with live  

 

    (brown) and neutral (blue) wires    

    only. to rewire, connect the wires  

    as indicated in diagram.  

   

dO NOt

 connect either wire to    

    the earth terminal.

1.1.10. Products which require more  

 

    than 13 amps are supplied  

 

    without a plug. In this case you    

    must contact a qualified electrician  

    to ensure that a suitably rated    

    supply is available. 

 

 

RECOMMENdEd 

FUSE RAtiNG:

  

13 AMP

Original Language Version

© Jack sealey limited

Summary of Contents for SAC5030VE

Page 1: ... or damage You must ensure that the risk of electric shock is minimised by the installation of appropriate safety devices A Residual Current Circuit Breaker RCCB should be incorporated in the main distribution board We also recommend that a Residual Current Device RCD is used It is particularly important to use an RCD with portable products that are plugged into a supply which is not protected by ...

Page 2: ...e read understood and apply Section 1 safety instructions 4 1 IMPORTANT The use of extension leads to connect this compressor to the mains is not recommended as the resulting voltage drop reduces motor and therefore pump performance and could damage your compressor 4 2 Take care when selecting tools for use with the compressor Air tool manufacturers normally express the volume of air required to o...

Page 3: ...fig 3 2 set to maximum pressure Make sure that pressure in the tank rises and that the compressor stops automatically when the max pressure value allowed written on the specification plate and shown on the gauge fig 3 6 is achieved The compressor will now operate automatically The pressure switch fig 3 8 stops the motor when the maximum tank pressure is reached and restarts it when pressure falls ...

Page 4: ...on the ring If valve continues to leak when in the closed position it should be replaced 1C Pressure drop in the tank Air leaks from cylinder head gasket Check tightness of head bolts If leak continues contact authorised Service Agent 2 Pressure switch valve leaks when compressor is idle Non return valve seal defective Empty the air tank Referring to fig 6 remove the non return valve cap 3 spring ...

Reviews: