background image

30L INDUSTRIAL DEHUMIDIFIER 

MODEL NO: 

SDH30.V3

Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these 

instructions, and properly maintained, give you years of trouble free performance.

IMPORTANT:

 PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE 

THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR 
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.

1.  SAFETY

1.1.   

 

ELECTRICAL SAFETY

 

‰

  

WARNING!

 It is the user’s responsibility to check the following:

 

Check all electrical equipment and appliances to ensure that they are safe before using. Inspect power supply leads, plugs and all  

 

electrical connections for wear and damage. Sealey recommend that an RCD (Residual Current Device) is used with all electrical  

 

products. You may obtain an RCD by contacting your local Sealey dealer. 

 

If the unit is used in the course of business duties, it must be maintained in a safe condition and routinely PAT (Portable Appliance  

 

Test) tested.

 

Electrical safety information, it is important that the following information is read and understood.

1.1.1.   

Ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply. 

1.1.2.   

Regularly inspect power supply cables and plugs for wear or damage and check all connections to ensure that they are secure.

1.1.3. 

  

IMPORTANT

: Ensure that the voltage rating on the appliance suits the power supply to be used and that the plug is fitted with the  

 

correct fuse - see fuse rating in these instructions.

 

8

   DO  NOT

 pull or carry the appliance by the power cable.

 

8

  

DO NOT

 pull the plug from the socket by the cable. 

 

8

   DO  NOT

 use worn or damaged cables, plugs or connectors. Ensure that any faulty item is repaired or 

 

replaced immediately by a qualified electrician.

1.1.4. 

  

This product is fitted with a BS1363/A 13 Amp 3 pin plug. 

        

 If the cable or plug is damaged during use, switch the electricity supply and remove from use. 

         

Ensure that repairs are carried out by a qualified electrician.

         

Replace a damaged plug with a BS1363/A 13 Amp 3 pin plug. If in doubt contact a qualified electrician.

 

a) Connect the GREEN/YELLOW earth wire to the earth terminal ‘E’.

 

b) Connect the BROWN live wire to the live terminal ‘L’.

 

c) Connect the BLUE neutral wire to the neutral terminal ‘N’.

        

Ensure that the cable outer sheath extends inside the cable restraint and that the restraint is tight. 

        

Sealey recommend that repairs are carried out by a qualified electrician. 

1.2.    

GENERAL  SAFETY

 

9

   Check that the dehumidifier is in sound condition and good working order. Take immediate action to repair or replace damaged parts.

 

9

   Use recommended parts only. Unauthorised parts may be dangerous and will invalidate the warranty.

 

8

  

DO NOT

 stand or place any object less than 10cm from the front or rear of the unit.

 

8

  

DO NOT

 obstruct the air intakes or outlets of the dehumidifier.

 

8

  

DO NOT 

place any object into the outlets - the unit has a fan running at high speed, contact with this will cause injury.

 

8

  

DO NOT

 operate the dehumidifier when you are tired or under the influence of alcohol, drugs or intoxicating medication.

 

8

  

DO NOT 

switch the dehumidifier off by disconnecting it from the mains. 

ALWAYS 

switch to the “OFF” position first.

 

8

  

DO NOT 

remove the float lever from the water collection tank.

 

8

  

DO NOT 

connect or disconnect the plug from the mains with wet hands.

 

9

   Always discard the water from the collection tank, 

DO NOT

 use it for any other purpose.

 

9

   Place the dehumidifier on a level and stable surface.

 

8

  

DO NOT

 use the dehumidifier at ambient temperatures below 5°C.

 

8

  

DO NOT

 use the dehumidifier outside. 

 

9

   When using continuous draining, make sure that the drain hose is positioned correctly.

 

9

   Ensure that heating appliances are not exposed to the flow of air from the dehumidifier.

 

9

   Before attempting to move the dehumidifier, empty the contents of the collection tank. 

 

9

   Switch off and disconnect it from the mains before attempting any cleaning or other maintenance work. 

 

9

   Ensure that the dehumidifier is correctly turned off when not in use, and stored in a safe, dry area, out of reach of children.

 

This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental  

 

 

capabilities or lack of experience or knowledge if they have been given supervision or instruction concerning use of the appliance in  

 

a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall  

 

not be made by children without supervision.

Original Language Version

© Jack Sealey Limited

Refer to 

instructions

Do not cover

Indoor use only

Caution: 

Risk of fire

Recommended fuse rating

13 Amp

S

DH30.V3     Issue 1     29/07/21

Summary of Contents for SDH30.V3

Page 1: ...Connect the BROWN live wire to the live terminal L c Connect the BLUE neutral wire to the neutral terminal N Ensure that the cable outer sheath extends inside the cable restraint and that the restraint is tight Sealey recommend that repairs are carried out by a qualified electrician 1 2 GENERAL SAFETY 9 Check that the dehumidifier is in sound condition and good working order Take immediate action ...

Page 2: ...le hinge point rotate the handle to the upright position and re fit the screws to fix it in place NOTE Once upright DO NOT use the unit for at least 2 hours 4 4 WATER TANK USAGE 4 5 You may use the water tank in two ways 4 5 1 DIRECT USE When the water tank is full the machine automatically shuts down and enters the standby state the LED displays the Full Water signal and the dehumidifier will ala...

Page 3: ...FROSTING 5 3 1 The defrosting device works automatically at an interval of approximately every 30 minutes for a duration of approximately 5 minutes when the coil temperature is tested to be minus 1o C The dehumidifying function will stop during the defrosting operation DO NOT disconnect the plug or turn off the unit during the defrosting operation The defrosting led light fig 3 7 will light up NOT...

Page 4: ...ier over with a dry soft cloth To remove dirt wipe over with a very slightly dampened cloth never use a wet cloth for cleaning the controls To avoid deformation or cracking do not use benzine thinner or liquid cleaners 6 2 5 When storing place in a safe dry childproof location Stand the unit upright and avoid exposure to direct sunlight 7 TROUBLE SHOOTING Faults Cause Analysis Solutions Fails to t...

Page 5: ...s according to local regulations WEEE REGULATIONS Dispose of this product at the end of its working life in compliance with the EU Directive on Waste Electrical and Electronic Equipment WEEE When the product is no longer required it must be disposed of in an environmentally protective way Contact your local solid waste authority for recycling information Note It is our policy to continually improv...