1.  SAFETY

1.1. 

  

ELECTRICAL SAFETY

 

‰

  

WARNING!

 It is the responsibility of the owner and the operator to read, understand and comply with the following:

 

You must check all electrical products, before use, to ensure that they are safe. You must inspect power cables, plugs, sockets    

 

and any other connectors for wear or damage. You must ensure that the risk of electric shock is minimised by the installation of    

 

appropriate safety devices. A Residual Current Circuit Breaker (RCCB) should be incorporated in the main distribution board. You  

 

must also read and understand the following instructions concerning electrical safety.

 

9

   Ensure that cables are always protected against short circuit and overload.

 

9

   Regularly inspect power supply cables and plugs for wear or damage and check all connections  

  to ensure that none are loose.

 

9

   Ensure that the voltage marked on the appliance matches the power supply to be  

  used and that the plug is fitted with the correct fuse - see fuse rating at right.

 

8

  

DO NOT

 use worn or damaged cables, plugs or connectors. Have any faulty item repaired or  

  replaced immediately by a competent electrician.

 

9

   It is recommended that this device is wired directly to a fused isolator switch. If, however, a plug  

  is fitted, the following applies:

 

9

   Fit a new plug according to the following instructions (UK only).

 

a) Connect the GREEN/YELLOW earth wire to the earth terminal ‘E’.

 

b) Connect the BROWN live wire to the live terminal ‘L’.

 

c) Connect the BLUE neutral wire to the neutral terminal ‘N’.

 

d) After wiring, check that there are no bare wires, that all wires have been correctly connected, 

 

    that the cable restraint is tight.

1.2.    

GENERAL  SAFETY

 

9

   Check that the dehumidifier is in sound condition and good working order. Take immediate action to repair or replace damaged parts.

 

9

   Use recommended parts only. Unauthorised parts may be dangerous and will invalidate the warranty.

 

8

  

DO NOT

 stand or place any object less than 10cm from the front or rear of the unit.

 

8

  

DO NOT

 obstruct the air intakes or outlets of the dehumidifier.

 

8

  

DO NOT

 place any object into the outlets - the unit has a fan running at high speed, contact with this will cause injury.

 

8

  

DO NOT

 operate the dehumidifier when you are tired or under the influence of alcohol, drugs or intoxicating medication.

 

8

  

DO NOT

 switch the dehumidifier off by disconnecting it from the mains. ALWAYS switch to the “OFF” position first.

 

8

  

DO NOT

 remove the float lever from the water collection tank.

 

8

  

DO NOT

 connect or disconnect the plug from the mains with wet hands.

 

9

   Always discard the water from the collection tank, 

DO NOT

 use it for any other purpose.

 

9

   Place the dehumidifier on a level and stable surface.

 

8

  

DO NOT

 use the dehumidifier at ambient temperatures below 5°C.

 

8

  

DO NOT

 use the dehumidifier outside.

 

8

  

DO NOT

 use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer.

 

9

   The appliance shall be stored in a room without continuously operating ignition sources (for example: open flames, an operating gas  

  appliance or an operating electric heater.

 

8

  

DO NOT

 pierce or burn.

 

9

   Be aware that refrigerants may not contain an odour.

 

9

   When using continuous draining, make sure that the drain hose is positioned correctly.

 

9

   Ensure that heating appliances are not exposed to the flow of air from the dehumidifier.

 

9

   Before attempting to move the dehumidifier, empty the contents of the collection tank.

 

9

   Switch off and disconnect it from the mains before attempting any cleaning or other maintenance work.

 

9

   Ensure that the dehumidifier is correctly turned off when not in use, and stored in a safe, dry area, out of reach of children.

 

This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental  

 

 

capabilities or lack of experience or knowledge if they have been given supervision or instruction concerning use of the appliance in  

 

a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall  

 

not be made by children without supervision.

 

‰

  

WARNING:

 If the power cord is damaged, it must be replaced by a professionally trained person.

Recommended fuse rating

13 Amp

SDH50.V3  Issue 1 30/03/2021

Original Language Version

© Jack Sealey Limited

Refer to 

instructions

Warning!  

Risk of fire

Do not cover

Indoor Use Only

Summary of Contents for SDH50.V3

Page 1: ...se recommended parts only Unauthorised parts may be dangerous and will invalidate the warranty 8 DO NOT stand or place any object less than 10cm from the front or rear of the unit 8 DO NOT obstruct the air intakes or outlets of the dehumidifier 8 DO NOT place any object into the outlets the unit has a fan running at high speed contact with this will cause injury 8 DO NOT operate the dehumidifier w...

Page 2: ...ironmentally friendly R290 May be connected to a drain hose for continuous operation Mounted on castors for manoeuvrability 3 SPECIFICATION MODEL NO SDH50 V3 CO2 Equivalent 0 0006t Condensate Tank 7L with Auto Shut Off Dehumidifying Capacity 50L day 30 CRH80 Freezing Pressure Max 2 5MPa Global Warming Potential Rating 3 IP Rating IP22 Maximum Airflow 350m hr Power Max Rated 900 750W Refrigerant R2...

Page 3: ...tandby state the LED displays the Full Water signal and the dehumidifier will alarm When the water tank is emptied and put in place again the dehumidifier can continue its performance 5 1 2 CONTINUOUS DRAINAGE As shown in Fig 3 to restore the performance of the water tank you need to take out the water tank and mount the drain pipe Note When using continuous drainage the drainage pipe shall not be...

Page 4: ...t s adjusted to the required value the dehumidifier accepts the new setting and the Timing On icon flickers Ranging from 0 to 24H and 0H as default 5 6 3 Set timer for powering off When it s powered on press the Timing Button As the Timing Off icon flickers and the time set flickers in relevant area press or to adjust the timing The dehumidifier makes a sound once the button is pressed When the ti...

Page 5: ...ormer is broken Replace the transformer Shown as power on Environmental humidity lower than the set value Set again according to the demand If the water tank is installed correctly Place the water tank in right position If the entire machine is defrosting Wait for the completion of defrosting cycle Unfavourable dehumidifying effect If the air inlet outlet is obstructed Remove the obstacle If the d...