VACUUM OIL & FLUID EXTRACTOR MANUAL 6.5LT
MODEL NO:
S01169
Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these
instructions, and properly maintained, give you years of trouble free performance.
IMPORTANT:
PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE
THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
1. SAFETY
WARNING!
Ensure health & safety, local authority, and general workshop practice regulations are strictly adhered to when using
this equipment.
9
Familiarise yourself with the extractors application and limitations, as well as the specific potential hazards peculiar to this product.
9
Maintain the extractor in good condition.
9
Replace or repair damaged parts. Use genuine parts only. Non authorised parts will invalidate the warranty.
9
Use only to extract engine or transmission oils, or similar NON-Corrosive fluids. Unit may also be used for the transfer of water.
9
Ensure safety eye protection and protective clothing are worn when using this product.
9
Keep the work area clean, uncluttered and ensure there is adequate lighting.
9
Maintain correct balance and footing. Ensure the floor is not slippery and wear non slip shoes.
9
Keep children and unauthorised persons away from the working area.
9
Dispose of waste liquids in accordance with local authority regulations.
8
DO NOT
store fluids in the container. Once used to extract fluid, it must be emptied into an approved receptacle as soon as possible.
8
DO NOT
use to extract hazardous or harmful chemicals, solvents, petrol, diesel, kerosene, alkaline or acids. If by chance such fluids
are used in the unit, it must be immediately drained and thoroughly cleaned. Use with prohibited fluids will invalidate your warranty.
8
DO NOT
dismantle, tamper or adapt the extractor for any purpose other than for which it is designed.
8
DO NOT
use the unit if it has been dropped or mishandled, check the unit to ensure there is no damage.
Keep the extractor clean
and store in a safe dry location.
8
DO NOT
store in areas of high temperature, direct sunlight, rain or snow.
2. INTRODUCTION
6.5ltr Capacity device constructed from composite materials and suitable for the extraction of all types of engine, transmission and lubricating oils
from cars, motorcycles, marine engines, stationary engines and industrial machinery. Also suitable for low viscosity fluids such as water. Supplied
with Ø4, Ø6 and Ø8mm suction probes and Ø10mm x 1mtr extension tube. To remove oil from a car engine, simply push the probe down the
dipstick hole and pump the handle on the top of the unit. Probes can be stored in the holder when not in use. Can also be used for draining fish
tanks, basins and sinks.
3. SPECIFICATION
Model No: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
S01169
Capacity:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6.5ltr
Suction Probes:
. .
Ø4 x 1000mm, Ø6 x 1000mm, Ø8 x 1000mm
Extension Tube:
. . . . . . . . . . . . . . . . . . . . . . . .
Ø10 x 1000mm
Nett Weight: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.20kg
4. OPERATION
4.1
OIL EXTRACTION (fig.1)
4.1.1. Ensure the vehicle is on level ground and run the engine for approximately 5 minutes to warm the oil and allow any contaminants
within the oil to thoroughly mix and turn the engine off.
4.1.2. Remove the vehicle’s oil dipstick.
4.1.3. Select and insert the appropriate diameter probe into the dipstick hole until it reaches the bottom of the sump.
4.1.4. Connect the extension tube to both the pump inlet and probe.
4.1.5. Raise the handle to its highest limit and pump it fully several times to create a vacuum which will automatically begin to extract the
oil/fluid. Observe the oil/fluid as it rises up the chamber and stop pumping when the fluid is 6”(150mm) from the top. The unit will
continue to fill and will automatically shut off when the internal float valve operates.
DO NOT
continue to pump after the unit has shut
off as this may result in liquid entering the inner pump chamber. If this should occur refer to section 4.1.8 on how to expel fluid from
the pump.
4.1.6. Once completed, remove the main suction tube from the pump, pour the oil/fluid into a suitable container (the unit can be tipped,
but no further than 90
°
, to facilitate emptying) and dispose of it in accordance with local authority regulations.
4.1.7. Before using the pump again press the vacuum release valve for 5 seconds to release the vacuum within the pump. This valve is
situated on the top of the unit underneath the handle.
4.1.8. In the event of fluid entering the inner pump chamber it can be expelled from the unit as follows. Firstly press the vacuum release
valve for 5 seconds to release the vacuum within the pump. Seal off the fluid entry/pouring hole by placing your hand over it, then
pump the handle up and down several times. Any fluid that has entered the pump will be expelled from the air valve on the underside
of the unit.
S01169 | Issue 2 (H,F) 22/10/18
Original Language Version
© Jack Sealey Limited
Refer to
instructions
Wear eye
protection
Wear protective
gloves
Wear safety
footwear
Wear protective
clothing
Do not tip unit beyond 90
°