background image

1.1. 

 

ELECTRICAL SAFETY

  

WARNING!

 It is the responsibility of the owner and the operator to read, understand and comply with the following:

   

You must check all electrical products, before use, to ensure that they are safe. You must inspect power cables, plugs, sockets and    

   

any other connectors for wear or damage. You must ensure that the risk of electric shock is minimised by the installation of  

 

   

appropriate safety devices. A Residual Current Circuit Breaker (RCCB) should be incorporated in the main distribution board. We also  

   

recommend that a Residual Current Device (RCD) is used. It is particularly important to use an RCD with portable products that are    

   

plugged into a supply which is not protected by an RCCB. If in any doubt consult a qualified electrician. You may obtain a Residual    

   

Current Device by contacting your Sealey dealer. 

   

You must also read and understand the following instructions concerning electrical safety.

1.1.1.  The Electricity at Work Act 1989 requires that all portable electrical appliances, if used on business premises, are tested by a qualified  

 

electrician, using a Portable Appliance Tester (PAT), at least once a year.

1.1.2.  The Health & Safety at Work Act 1974 makes owners of electrical appliances responsible for the safe condition of those appliances    

 

and the safety of the appliance operators. If in any doubt about electrical safety, contact a qualified electrician.

1.1.3.  Ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply. See 1.1.1. and 1.1.2.   

 

and use a Portable Appliance Tester.

1.1.4.  Ensure that cables are always protected against short circuit and overload.

1.1.5.  Inspect regularly power supply cables and plugs for wear or damage and check all 

 

connections to ensure that none is loose.

1.1.6.  Important: Ensure that the voltage marked on the appliance matches the power supply 

 

to be used and that the plug is fitted with the correct fuse - see fuse rating at right.

1.1.7. 

DO NOT

 pull or carry the appliance by the power cable.

1.1.8. 

DO NOT

 pull the plug from the socket by the cable.

1.1.9. 

DO NOT

 use worn or damaged cables, plugs or connectors. Immediately have any faulty 

 

item repaired or replaced by a qualified electrician. When a BS 1363/A UK 3 pin plug 

 

is damaged, cut the cable just above the plug and dispose of the plug safely. 

 

Fit a new plug according to the following instructions (UK only).

 

a) Connect the GREEN/YELLOW earth wire to the earth terminal ‘E’.

 

b) Connect the BROWN live wire to the live terminal ‘L’.

 

c) Connect the BLUE neutral wire to the neutral terminal ‘N’.

 

d) After wiring, check that there are no bare wires, that all wires have been correctly connected, that the cable outer insulation extends  

 

beyond the cable restraint and that the restraint is tight. Double insulated products, which are always marked with this symbol    , are  

 

fitted with live (brown) and neutral (blue) wires only. To rewire, connect the wires as indicated above - 

DO NOT

 connect either wire to  

 

the earth terminal.

1.1.10.  Products which require more than 13A are supplied without a plug. In this case you must contact a qualified electrician to ensure  

 

 

that a suitably rated supply is available. We recommend that you discuss the installation of an industrial round pin plug and socket    

 

with your electrician.

1.1.11.  If an extension reel is used it should be fully unwound before connection. A reel with an RCD fitted is preferred since any appliance    

 

plugged into it will be protected. The cable core section is important and should be at least 1.5mm², but to be absolutely sure that the  

 

capacity of the reel is suitable for this product and for others which may be used in the other output sockets, we recommend the use   

 

of 2.5mm² section cable.

1.2. 

GENERAL SAFETY

  Disconnect the sharpener from the mains power before changing accessories, servicing or performing any maintenance.

  Maintain sharpener and stone in good condition. Check moving parts and alignment. If necessary use an authorised service agent.

  Replace or repair damaged parts. Use genuine parts only. Unapproved parts may be dangerous and will invalidate the warranty.

  The grinding wheel or stone must only be changed by persons holding an appropriate grinding wheel certificate.

  Wear approved safety goggles. 

  Remove ill fitting clothing. Remove ties, watches, rings, and other loose jewellery, and contain long hair.

  Use sharpener in a suitable work area, keep area clean, tidy and free from unrelated materials, and ensure adequate lighting.

  Maintain correct balance and footing. 

DO NOT 

over-reach and ensure the floor is not slippery. Wear non slip shoes.

  Keep non essential persons away from the working area.

 

DO NOT

 operate the sharpener if any parts are missing or the sharpener is damaged.

 

DO NOT

 use the sharpener for a task it was not designed to perform.

 

DO NOT

 operate sharpener where there are flammable liquids or gasses.

 

DO NOT

 get the sharpener wet or use in damp or wet locations. 

 

DO NOT

 switch the sharpener on whilst the stone is in contact with the workpiece.

 

DO NOT

 touch the workpiece immediately after sharpening as it will be very hot.

Original Language Version

©  Jack Sealey Ltd

INSTRUCTIONS FOR:

MULTIPURPOSE SHARPENER - BENCH 

MOUNTING

MODEL NO:

 

SMS2004

RECOMMENDED FUSE RATING 5 AMP

 

IMPORTANT:

 

PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT 

CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL 

INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.

Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these 

instructions and maintained properly, give you years of trouble free performance.

Refer to

instructions

Wear eye 

protection

Indoor

use only

SMS2004    Issue:4  (H,F) - 22/01/18

1.  SAFETY 

Summary of Contents for SMS2004

Page 1: ...ymbol are fitted with live brown and neutral blue wires only To rewire connect the wires as indicated above DO NOT connect either wire to the earth terminal 1 1 10 Products which require more than 13A are supplied without a plug In this case you must contact a qualified electrician to ensure that a suitably rated supply is available We recommend that you discuss the installation of an industrial r...

Page 2: ...uld now be touching the V guide sides 4 1 6 Ensure that the drill and holder are fully down in the setting slot With the drill in this position tighten the clamping ring 1d 4 1 7 Lift up the V guide and remove the clamp holder and drill bit 4 1 8 Transfer the clamp holder to the sharpening position on the right hand top 1e secure it with light finger pressure 1f 4 1 9 Switch the power unit on Fig ...

Page 3: ...ORS 4 2 8 Open the scissors fully 4 2 9 Slide the first scissor blade through the front guide slot from left to right 2d keeping the pivot of the scissors and the other blade to the right hand side 4 2 10 Draw the blade across the grinding wheel from pivot to tip Use a light steady pressure DO NOT press too hard 2e 4 2 11 Remove and turn scissors over to sharpen the second blade 2f keep the pivot ...

Page 4: ...ore removing the module ensure that the grinding wheel has stopped 4 3 11 It is recommended that after grinding the blade tip is honed on an oil stone 5 maintenance 5 1 Before cleaning disconnect from the mains Keep clean and free from oil and grease store in dry conditions Fig 4 Original Language Version SMS2004 Issue 4 H F 22 01 18 Sealey Group Kempson Way Suffolk Business Park Bury St Edmunds S...

Reviews: