NOVASUB - DDG-P QUICKSTART GUIDE - R1.1 

WWW.NOVASUB.COM 

R1.0        1 of 2 

 

Manufactured by Seascape.nl 

Action 

Description 

Needed 

Installation 

  Connect both probe cables and probes to the SCC-DDG-P side 

panel 

  Connect external 100-230 vac power 

 

2x UDS-2 pressure 
sensor with cables 

Power Up 

Press Power button to start the DDG 

 

Calibration 
preparations 

  Place both sensors vertical together 

  Connect the measuring tap 0 on the measuring point of the sensors 

  Make sure that both cables are long enough so that the pressure 

sensors can be lowered to the max. calibration point 

Measuring tape 

Initial calibration 

(Do the initial 
calibration on each 
new project 
location)

 

1.  Press Menu and go to Maintenance 

 Admin settings

Login 

Admin 

2.  Type password: OK+--+OK and OK again 
3.  Go to Menu Calibrations in Admin settings Menu 
4.  Select P1 and P2 and press OK 
5.  With Both pressure sensor in the air above and out of the water 

press, OK 

6.  Lower down both Pressure sensors to the max. calibration depth 

and read the exact depth at the measuring tape water surface line. 

7.  Enter the value in millimetres , use + and 

– buttons to select value 

and press OK to go to next digit. Press OK after last digit. 

8.  Make sure pressure sensors are on the entered water depth, Press 

OK to set the WCcalMax. 

9.  Reboot the DDG-P 

 

Reference point 
NAP-ref. 

(Reference point of 
the project to which 
p1 if referenced to)

 

1.  Press Menu and go to Maintenance 

 Admin settings

Login Admin 

2.  Type password: OK+--+OK and OK again 
3.  Go to Menu Calibrations in Admin settings Menu 
4.  Select Config NAP ref and press OK 
5.  Enter the value in millimetres , use + and 

– buttons to select value 

and press OK to go to next digit. Press OK after last digit. 

 

 

Installing P1 

P1 needs to be placed vertical in water approx. 0,5 m below water level 
and deep enough that the water level never gets below the depth 
sensor. 

 

Measure the exact distance from bottom of P1 to NAP-ref. point 

Measuring tape 

Level P1 settings 

1.  Login in Admin settings Menu 
2.  Go to Menu Calibrations in Admin settings Menu 
3.  Select Config Level P1 and press OK 
4.  Enter the value of Level-P1 in millimetres , use + and 

– buttons to 

select value and press OK to go to next digit. Press OK after last 
digit. 

 

P-offset 

The P-offset is fixed for the standard supplied UDS-2 sensor. 

Do not 

change

.  

 

Logging 

1.  T

he “Dive monitor” shows “ Press OK to start log”  on the display  

2.  Start the next log by pressing OK 
3.  To log a point Press OK 
4. 

Continue Pressing “OK” to log a new point 

5. 

Stop logging  by pressing “MENU” and “OK” 

6.  Logfile:  X  shows  the  file  number  and  Point:  x  shows  the  point 

number in the logfile. Each point is stored in the file with all data. 

 

 
 

 