MobilGate - 128c

Gate and barrier control GSM module with

2 inputs and 2 outputs for 128 phone numbers

MobilGate-128c

is an industrial GSM module developed for remotely controlling doors, garage

doors and barriers with 2 opto-isolated inputs and 4 high current relay outputs. The 2 relay outputs
allow the configuration of 128 phone numbers to control the gates remotely with a free call based on
caller ID recognition. The 2 relay outputs can be triggered by SMS orders received from previously
configured phone numbers. Relays operated with a free call can be triggered for pre-determined
duration, and the relays operated with SMSs can be turned on and off permanently. The recognition
of maximum 128 phone numbers allows to set up entitlements for 128 users. The general inputs can
be used arbitrarily for transmitting gate error signals,  burglary alarm center's signals or panic signals.

Users are informed about input changes via
SMS with pre-configured content. Certain
electronic devices, such as heaters, air
conditioners, light devices etc. can be
turned on and off with relay outputs
operated via SMSs, thus the function of
gate opener can be broadened with many
supplements. Its power voltage is 10-30V,
which can be supplied by a power adapter.
Its setup can be configured with our free
downloader software via USB port, or by
sending several different configuration SMS
remotely. Each input and output can be
labeled with a max. 16-character long name.

The configuration of the SMS relay output commands which trigger the relays to be on or off also
can be set. The module also has a 4-character passcode in order to prevent any unauthorized
personnel to disable or reconfigure the module. The GSM gate opener has internal timers, thus the
output relays are triggered for a configured time when calls occur, which can be maximum of 9999
seconds (about 3 hours). After the given time expires, the relays turn off automatically and return to
their original state.

1.    Operation of MobilGate-128c

The GSM gate opener is equipped with a carrier-independent industrial GSM module; thus it

is ready for SMS-based communication with a prepaid or subscription SIM card without PIN code.
The data which is necessary for operation, for instance SMS number of the service provider, users’
numbers, output and input names etc. can be configured by downloading them into the device or
sending an SMS with a certain content. In the case there is any change of the inputs, the module
name, module number, the appropriate input name and status are also sent via SMS. The detailed
messages provide possibility to be able to easily identify the appropriate device in case of having
more than one. Input and output status with every parameter can be queried by sending a
corresponding SMS. Configuration SMSs are confirmed after reception, and an incorrect
configuration SMS will result in an error message. The module does not discard the previously set
configuration, including input names, output status, phone numbers, etc. after turning the device off.
After power-up, although timer parameters are deleted, but the module continues its operation where

 SeaSoft  Ltd.    

                www.seasoft.hu  -  www.mobil-control.eu                    T: (+36) 62 406405       M: (+36) 30 2557688        F: (+36) 62 405-969  

Summary of Contents for MobilGate - 128c

Page 1: ... which trigger the relays to be on or off also can be set The module also has a 4 character passcode in order to prevent any unauthorized personnel to disable or reconfigure the module The GSM gate opener has internal timers thus the output relays are triggered for a configured time when calls occur which can be maximum of 9999 seconds about 3 hours After the given time expires the relays turn off...

Page 2: ...tinuously The interface is operational It has to remain lit after turning it on White GSM LED Blinking GSM module operational status It has to light up after around 25 seconds then flash according to its functioning Its flashing indicated that the device is connected to the network Green Heartbit LED Blinking It is the life signal of the device When the device is turned on it does not blink until ...

Page 3: ... maximalum load is 230V and 8A The No Com and Nc points of the relays are wired out The GSM modem has a screwed SMA aerial connector and a small sized pole aerial or an aerial with a coax cable or similar plug can also be installed to it The power input of the GSM gate opener module is protected against reverse polarity and it is equipped with 500mA multifuse The input voltage on the general purpo...

Page 4: ...bilGate 128 controller freely in configuration mode If the software cannot find the port of the device indicated on the picture it has to be identified manually in Windows by the followings Control Panel System Hardware Devices Ports The GSM device has to be identified by which serial port from Com1 Com99 it is connected to Manual configuration is necessary when previously a lot of USB devices had...

Page 5: ...Ss it can be read and checked It is advised to always start configuration with a file named Default mob It is easier to edit uploaded data without making any mistake than creating new values It is important to fill out the required fields and avoid the use of accented characters for names and commands because the module does not recognize accented characters Fill the phone numbers in international...

Page 6: ...n by the output status on screen located below the inputs statuses The software can handle every version of the MobilGate family It automatically recognizes the 32 and 128 version of the device family and it allows to open the group of mobile numbers beyond 32 in case of the 128 version After finishing the configuration please reset the module to verify the changes It can be done by clicking on th...

Page 7: ...rs 1234 9876 02 Device identifier 4 scharacters 0001 0007 03 Name of device Max 16 characters My house My castle 04 Restore report of inputs 0 no 1 yes 1 1 05 Name of input 1 Max 16 characters Gate Barrier 06 Name of input 2 Max 16 characters Pushbutton Alarm system 07 Relay s switch on time Between 0 9999 sec 0005 0012 08 Switch on SMS command of relay 3 Max 16 characters Light on alarm on 09 Swi...

Page 8: ...ll switch on for the given time when called 36 30 1234 567 last 11 characters means the phone number on memory place 29 Using the two tables above with the same logic with using the correct syntax for the given memory space every memory space can be loaded via an SMS Default settings remain in the unchanged memory spaces Loading memory spaces by SMSs can take some time therefore it is advised to u...

Page 9: ... place command which see table is the retraction command of relay 3 Relay 3 will turn on Attention The device will execute the given command if it is identical to the command given in the memory If the sent SMS does not match with any SMS command the module will send back an Error message 8 Further notes Regarding to the device functionality GSM networks and the specialty of GSM voice calls and SM...

Page 10: ...howing the caller ID must be enabled This can be performed by contacting the carrier s customer service h Call forwarding and SMS reminders about missed calls sent by the carrier must be disabled on the SIM card 9 Connecting the MobilGate 128c 10 Specifications Power supply 10 30 Vdc GSM Dual band Max Current 290 mA Frequency 900 1800MHz Stdby current relays on 27 mA Communication SMS voice Stdby ...

Page 11: ...Appendix modificatons of of setting of USB serial Com port in Windows 7 step by step SeaSoft Ltd www seasoft hu www mobil control eu T 36 62 406405 M 36 30 2557688 F 36 62 405 969 ...

Reviews: