User manual
W2 Quick reference Programming Guide
Enter the programming mode
To exit the programming mode
Change the master code
(888888 is the default factory master code)
0 New code # Repeat New code #
(Code must be 6-8 digit numbers.)
Choose from the relevant function below and input
Function description
.7.
.8.
.9.
.10.
Attachment: Advanced Application
1. W2 operating as a Controller
In this mode the W2 supports a Wiegand 26 bit input so an external Wiegand device
with a 26 bit output can be connected to the Wiegand input terminals on the W2. Either
an ID card reader (125 KHZ) or an IC card reader (13.56MHZ) can be connected to the
W2. Cards are required to be added at the external reader, except where an external
EM reader is used, in this case cards can be added at either reader or controller. See
figure 1
Figure 1
D0
D1
+12V
GND
-
+
Lock
-
+
Em card
HID card
Ic card
DC12V/3A
+
-
Power
D0
D1
ALARM-
OPEN
D_IN
+12V
GND
VSS
L-
L+
ALARM+
J1
Green
White
Grey
Yellow
Brown
Red
Black
Blue
Purple
Orange
wiegand reader
reader plug
W2 controller
Alarm
Exit button
door detecting switch
2. W2 operating as a Wiegand Output Reader
In this mode the W2 supports a Wiegand 26 bit output so the Wiegand data lines can be
connected to any controller which supports a Wiegand 26 bit input. See figure 2
figure 2
ALARM+
J1
White
Grey
Yellow
Brown
Red
Black
Blue
Purple
Orange
D0
D1
W2
+
-
Powerful supply
Controller with wiegand 26 input
+12V
GND
Controller
Green
D0
D1
ALARM-
OPEN
D_IN
+12V
GND
VSS
L-
L+
3. Two W2 units interconnected for a single door
In this mode two W2 units are used for a single door, one for entry and the other for exit.
Either device acts as the controller and reader at the same time. Users can be
enrolled in either of the devices. In this mode the user capacity for one door can be
up to 20000. The setting of the two W2 units must be the same including the master
code. See figure 3
Exit button
-
+
Lock
door detecting switch
-
+
Alarm
DC12V/3A
+
-
Power
indoor
outdoor
D0
D1
ALARM-
OPEN
D_IN
+12V
GND
VSS
L-
L+
ALARM+
J1
Green
White
Grey
Yellow
Brown
Red
Black
Blue
Purple
Orange
D0
D1
ALARM-
OPEN
D_IN
+12V
GND
VSS
L-
L+
ALARM+
J1
Green
White
Grey
Yellow
Brown
Red
Black
Blue
Purple
Orange
W2 controller 2
W2 controller 1
4. Two W2 units interconnected & interlocked for 2 doors
In this mode two W2 units are used for two doors which are then interconnected and
interlocked. In this mode the doors can be interlocked so that when door 1 is open, door
2 cannot be opened, and vice versa. The interlocked function is mainly used in banks,
prisons, and other places where a higher level of security is required. See figure 4
door detecting switch 1
-
+
-
+
DC12V/3A
+
-
Power
W2
controller 2
Door 2
Alarm 2
Alarm 1
Exit button 1
door detecting switch 2
Exit button 2
Door 1
W2
controller 1
D0
D1
ALARM-
OPEN
D_IN
J1
Green
White
Grey
Yellow
Brown
D0
D1
ALARM-
OPEN
D_IN
J1
Green
White
Grey
Yellow
Brown
-
-
+
+
Lock 1
Lock 2
+12V
GND
VSS
L-
L+
ALARM+
Red
Black
Blue
Purple
Orange
+12V
GND
VSS
L-
L+
ALARM+
Red
Black
Blue
Purple
Orange
5. Anti-submarine function for single door (3 1 #)
The connection diagram is as figure 1. Install one Wiegand reader (or a W2 without user
information as reader) outside the door, connecting to one W2-Controller inside the
door, which acts as the Anti-submarine Master unit. of the two devices, they build up an
anti-submarine system for single door. The operation and function is as below:
5.1
Set the needed function and enroll the User Cards on the inside W2 - Anti-
submarine Master unit.
5.2
With the valid user card, the user can only enter the door from the outside reader,
and exit from the inside W2 Controller. On the other hand, without entering record from
the reader, the user can't exit from the controller inside, also, the user can't enter in
twice without the first exit record , and vice versa.
6. Anti-submarine function for 2 doors
The connection diagram is as Figure 4. Door 1 with one W2, and Door 2 with one W2,
set one W2 on Door 1 as the Anti-submarine Auxiliary unit (3 2 # ), and set the other
W2 on Door 2 as the Anti-submarine Master unit(3 1 # ). They build up a two doors
anti-submarine system, which is normally used for parking lot......etc.
The operation and function is as below:
6.1
Set the needed function and enroll the User Cards from W2 - Anti-submarine Master
unit on Door 2.
6.2
With the valid user card, the user can only enter in from Door 1, and exit from Door 2.
On the other hand, without entering record from the Auxiliary unit, the user can't exit
from the Master unit or Auxiliary unit , also, the user can't enter in twice without the first
exit record , and vice versa.
then you can do the programming
* 888888 #
*
Note:
that to undertake the following programming the master user must
enter into the programming mode
Add card user
1 Read Card #
( Can add card continuously)
Delete card user
2 Read Card #
( Can delete card continuously)
Read user card
To Unlock the door
To Unlock the door
figure 3
figure 4
Standalone Proximity Reader
W2
Waterproof