Outdoor Wave-to-Open Sensors 

Installation Manual 

SD-9263-KSVQ 

shown 

5024193

 

Conforms to 

UL294 

 

 

 

SD-9163-KSVQ 

shown 

SD-9463-KSVQ 

shown 

Language 

Slimline 

Single-Gang 

European Plate* 

Double-Gang 

English 

SD-9163-KSQ 

SD-9263-KSQ 

SD-9363-KSQ 

 

Spanish 

SD-9163-KS1Q 

SD-9263-KS1Q 

SD-9363-KS1Q 

 

French 

SD-9163-KS2Q 

SD-9263-KS2Q 

SD-9363-KS2Q 

 

English 

w/ mechanical 
override button

 

SD-9163-KSVQ 

SD-9263-KSVQ 

SD-9363-KSVQ

  

SD-9463-KSVQ

 

*

European plate versions are not ETL certified. 

Spanish and French faceplates also available for these models by special order. 

The ENFORCER Outdoor Wave-to-Open Sensor is a full-featured exit plate using IR technology to 
allow egress from a protected area or activate a device with the simple wave of a hand. Since no 
touch is required, this sensor is suitable for use in hospitals, clinics, labs, cleanrooms (to reduce 
the risk of contamination), schools, factories, or offices.  

 

Adjustable sensor range up to 7" (18cm) 

 

1.2A relay, adjustable trigger duration 0.5~30 seconds or toggle 

 

LED illuminated sensor are for easy identification 

 

Selectable LED colors turns from red to green (or green to red) when the sensor is activated 

 

Stainless steel plate 

 

IP65 Weather-resistant for outdoor use 

 

Power must be provided by low-voltage power-limited/Class 2 power supply 

 

Use only low-voltage field wiring and do not exceed 98.5 ft (30m) 

Summary of Contents for SD-9163-KSQ

Page 1: ... Wave to Open Sensor is a full featured exit plate using IR technology to allow egress from a protected area or activate a device with the simple wave of a hand Since no touch is required this sensor is suitable for use in hospitals clinics labs cleanrooms to reduce the risk of contamination schools factories or offices Adjustable sensor range up to 7 18cm 1 2A relay adjustable trigger duration 0 ...

Page 2: ... 7 oz 77g 4 4 oz 125g N A 5 6 oz 160g Color function reversible When properly installed Overview INSTALLATION NOTES This product must be electrically wired and grounded in accordance with local codes or in the absence of local codes with National Electric Code ANSI NFPA 70 latest edition or the Canadian Electrical Code CSA C22 1 Due to the nature of IR technology an IR sensor can be triggered by a...

Page 3: ...nging the LED Color Slimline Models Other Models Adjusting the Sensor Range and Output Duration 1 The sensor range can be adjusted from 2 7 5 18 cm 2 Output duration can be adjusted from 0 5 30 seconds or toggle NOTE Do not force the adjustment trimpots to turn Only minimal force is needed Red Wire 12 24 VDC Brown Wire Ground Blue Wire COM Purple Wire N O Green Wire N C Red Wire 12 24 VDC Brown Wi...

Page 4: ...ion prepaid to SECO LARM This Warranty is void if damage is caused by or attributed to acts of God physical or electrical misuse or abuse neglect repair or alteration improper or abnormal usage or faulty installation or if for any other reason SECO LARM determines that such equipment is not operating properly as a result of causes other than defects in material and workmanship The sole obligation ...

Reviews: