2. Remove clamp from the controller and push the

controller into the panel cutout. Secure the controller in
its place by pushing the clamp on rear side.

3. For proper sealing, tighten the screws evenly with

required torque.

The equipment in its installed state must not come in

close proximity to any heating sources, caustic vapors,
oils, steam, or other unwanted process by-products.

1. Use proper input power cables with shortest connections

and twisted type.

2. Layout of connecting cables shall be away from any

Internal EMI source.

CAUTION:

EMC Guidelines:

All safety related codifications ; symbols and instructions

that appear in this operating manual or on the equipment
must be strictly followed to ensure the safety of the operating
personnel as well as the instrument.

If the equipment is not handled in a manner specified

by the manufacturer it might impair the protection provided
by the equipment.

Read complete instructions prior to
installation and operation of the unit.
Risk of electric shock.

CAUTION :

CAUTION :

selec

Operating Instructions

PIC152N

OP168-V04

SPECIFICATIONS

48 x 96

DISPLAY

POWER

SETTINGS

MEMORY

MAIN SENSOR INPUT

Thermocouple inputs

4-digit (7 segment LED) 0.5" height Display Messages:

Display alternating between PV and ALrM with LED of
respective alarm flashing.
(Programmable annunciator
LED Status Annunciators - Alarm ON (2 nos)

85 to 270V AC/DC (AC : 50 or 60Hz),
5VA (Optional) - 24V DC

Via three keys on front panel.

Nonvolatile EEPROM retains all programmable
parameters and values.

(Universal)

J

: -200 to 750 C

K

: -200 to 1350 C

T

: -200 to 400 C

R

: 0 to 1750 C

“Or” -   a) Appears when measurement exceeds

display scaling range(9999) for signal inputs
b) When open sensor is detected. (Applicable
for TC/RTD/-5 to 56mV)

“rE”

a)  Appears when measurement is below
display scaling range (-1999) for signal inputs.
B) Sensor reverse condition occurs.
(Applicable for TC/RTD/mV)

option)

S

: 0 to 1750 C

PT100 : -100 to 850 C

mV (linear) :  - 5 to 56mV
Voltage

:  0 - 10V DC

Current

:  0 - 20mA DC

Temperature : 0.25% of Span 1 C (20min.Warmup)
Signal input : 0.05% 1 digit

2 nos : Relay output : 5A @ 250V AC or 24V DC
Alarm modes - Alarm High, Alarm Low, Band, Fault
output and Fault diagnosis.
Hysteresis - Programmable.
Annunciator - Programmable.
Reset Action - Programmable : automatic or latched.
Standby Mode - Programmable : enable or disable.

24V DC supply to power the sensor

(optional)

Re-transmission : 4 to 20mA or 0 to 5V or 0 to 10V
Update rate : 100msec.

RTD input (2 wire or 3 wire)

Signal inputs

INDICATION ACCURACY

ALARM OUTPUTS

SENSOR SUPPLY

LINEAR DC OUTPUT

o

o

o

o

o

o

o

±

±

ENVIRONMENTAL CONDITIONS

ISOLATION BREAKDOWN RATINGS

CONNECTION

WEIGHT

Operating Range :

0 C to 50 C

Storage Range

: -20 C to 75 C

Humidity

: 85% max.

AC line with respect to all inputs and outputs : 2000
Volts. All other inputs and outputs with respect to
relay contacts : 2000V AC

Wire clamping screw terminals

300 grams

o

o

o

o

MECHANICAL INSTALLATION

For installing the controller

1. Prepare the panel cutout with proper dimensions as

shown

TERMINAL CONNECTIONS

SAFETY PRECAUTIONS

WIRING GUIDELINES

CAUTION :

1. To prevent the risk of electric shock power supply to

the

2. Wiring shall be done strictly according to the terminal

layout with shortest connections. Confirm that all
connections are correct.

3. Use lugged terminals to meet M3 screws.
4. To eliminate electromagnetic interference use of short

wire with adequate ratings and twists of the same in
equal size shall be made.

5. Cable used for connection to power source, must have

a cross section of 1mm or greater. These wires shall
have insulation capacity made of at least 1.5KV.

1. The equipment should be cleaned regularly to avoid

blockage of ventilating parts.

2. Clean the equipment with a clean soft cloth. Do not

use Isopropyl alcohol or any other cleaning agent.

equipment must be kept OFF while doing the wiring

arrangement.

2

MAINTENANCE

TERMINAL

TERMINAL DESCRIPTION

Neutral

Live

+ve mA

+ve V

+ve mV / TC / RTD1

- ve mV / TC- / RTD 2 / -ve mA / - ve V

-ve analog output

NO for relay1

NO for relay2

COM for relay1

COM for relay2

NC for relay1

NC for relay2

GND / -ve sensor supply

+24 V / +ve sensor supply

+ve analog output

N

L

3

4

5

8

11

14

12

15

17

13

16

18

2

9

NO2 COM2

COM1 NC1

NO1

1

2

3

4

5

6

7

8

9

14

15

10

11 12

13

L

N

16

ANALOG

OUTPUT

sensor supply

-

+

17

18

mA / V-

mA+

V+

+

mV/TC/RTD

A

-

+

-

GND +24V

NC2

+

22

21

23

24

-

B

B’

INSTALLATION GUIDELINES

CAUTION :

CAUTION :

1. This equipment, being built-in-type, normally becomes

a part of main control panel and in such case the
terminals do not remain accessible to the end user
after installation and internal wiring.

2. Conductors must not come in contact with the internal

circuitry of the equipment or else it may lead to a
safety hazard that may in turn endanger life or cause
electrical shock to the operator.

3. Circuit breaker or mains switch must be installed

between power source and supply terminals to
facilitate power 'ON' or 'OFF' function. However this
switch or breaker must be installed in a convenient
position normally accessible to the operator.

1. The equipment shall not be installed in environmental

conditions other than those mentioned in this manual.

2. Fuse Protection : The equipment does not have a built

in-type fuse. Installation of external fuse of rating 275V
AC/1Amp for electrical circuitry is highly recommended.

3. Thermal dissipation of equipment is met through

ventilation holes provided on chassis of equipment.
Such ventilation holes shall not be obstructed else it
can lead to a safety hazard.

4. The output terminals shall be strictly loaded to the

manufacturer specified values/range.

97.5

88

10

50

45

92

46

OUTLINE

Dimensions (in mm)

PANEL CUTOUT

Dimensions

(in mm)

FRONT PANEL DESCRIPTION

Key press

Functions

To enter or exit program mode

To change levels

To view function on the
same level and to display
the current option.

To increase or decrease the
value of a particular function.

+

together for 3 seconds

or

till Level is displayed.

+

/

to increase or

decrease the level number.

key once to view

next / previous function.

to increase and
to decrease the

value of particular function.

NOTE :

The unit will autoexit program mode after

60

of inactivity.

seconds

selec

PIC152

ALM

1

2

or

+
+

Lock code

Enter valid lock code as set
in the

parameter of

level 0.

To enter or exit program mode :
Press

&

together for 3 seconds

Press     +
for 3sec

NOTE :

J1

Lock code will not be prompted if jumper

(besides the calibration jumper) is present.

PIC15

2

selec

R2

R1

Insert

Jumper J1

PROGRAMMING OF LEVELS

PROGRAMMING OF LEVEL 0

Parameters in this level
can be set.

Press

+

Press

Press

+

Press

+

Press

+

Press

+

Press

+

Press

+

Press

+

Press

+

Display

for 1sec

Input sensor
selection

J ( -200 to 750 C )

o

K (-200 to 1350 C)

o

T (-200 to 400 C)

o

R (0 to 1750 C)

o

S (0 to 1750 C)

o

PT100 ( -100 to 850 C)

o

10V DC

20mA DC

Default setting : J

mV (linear) -5 to 56mV

Press     key to select input sensor type

KEY PRESS

DISPLAY

DESCRIPTION

Doc name : OP INST PIC152N

OP168 V04 (Page 1 of 4)

Summary of Contents for PIC152N

Page 1: ...e of short wire with adequate ratings and twists of the same in equal size shall be made 5 Cable used for connection to power source must have across section of 1mm or greater These wires shall haveinsulation capacity made of at least 1 5KV 1 The equipment should be cleaned regularly to avoid blockage of ventilating parts 2 Clean the equipment with a clean soft cloth Do not use Isopropyl alcohol o...

Page 2: ...y value scaling point 2 Range DSCL to 9999 For AIN display as per decimal point selected Default value 9999 Display value scaling point high DSCH to change value to change value mark explained in the user guide AIN Analog Input Note KEY PRESS DISPLAY DESCRIPTION Input value scaling point high ISCH Range ISCL to 20 00mA 56mV 10 00V default value changes as per analog input selected Press key to sel...

Page 3: ...ection for retransmission mode Adjust the display to 0 Select the Input type as RTD is displayed is displayed display momentarily Eg 1 For Temperature Input Input RTD Input Retransmission output 4 20 mA Desired output 4mA at 0 C 20mA at 400 C Settings 0 0 Press Press Press Press Press Using Press till till Press Press Press USER GUIDE USER GUIDE ALARM MODES High Alarm Low Alarm Band Alarm Fault Di...

Page 4: ...0 500 0 10 0 700 0 500 0 10 0 K PT100 Voltage VDC Current mA The thermocouple RTD curves are linearised in this microprocessor based product and hence the values interpolated between the readings shown above are also equally accurate at every point in the curve Unit is accepted as accuracy is within the specified limit of claimed accuracy and certificate is valid up to one year from the date of is...

Reviews: