background image

Power Consumption

4W Max

Operating Temperature

0 to

C

0

0

55

Storage Temperature

- 0 to 8 C

3

0

0

0

Humidity

95% RH

Certification

CE, UL (Pending)

Dimensions(WxHxD)mm

99 x 99 x 62.85

Panel Cutout(WxH)mm

92 x 92

Weight

275gms

selec

SP3-GT35

Operating Instructions

Ø
Ø
Ø
Ø
Ø
Ø
Ø
Ø

3.5" LCD with Touch
Built in Buzzer
10 password levels
Modbus protocol
Alarms
Recipe Management
Serial Printing
Data Logging

FEATURES

OP404-V01

Resolution

Backlight

320 x 240 pixels

LED backlight

SPECIFICATIONS

Display Type

Display Size(WxH)mm

3.5" TFT LCD (256 color), Resistive Touch Screen

70.08 x 52.56

selec

SP3-GT35

Font

16 MB (System Memory)

4 MB

BMP

Total

Application

4 MB

512 KB

Slave Port

Master Port

RS232 (MODBUS RTU)

RS485 (MODBUS RTU)

Brightness Adjustment

Yes (Via Internal MMI)

Keys

System key X 1, Function keys X 5

Operation Voltage

18 - 30VDC

Backup Battery

Battery Life

Buzzer

Type

Sound Output

Operation

Replaceable 3V CR2032

1 year at 25 C

0

Electro Magnetic Buzzer

85 dB at 10cm

Software Programmable

Printer Port

RS232 (LX300 Protocol)

LCDMODULE

COMMUNICA

TION

Doc. Name : OP INST SP3-GT35 OP404-V01(Page 1 of 2)B-B

Accuracy

+/- 10 min per Year

RealT

ime

Clock(RTC)

Upload

5.5 MB

External

Micro SD upto 2 GB (User Memory)

System Reserved

2 MB

MEMOR

Y

This manual is meant for personnel involved in wiring,

installation, operation and routine maintenance of the
equipment.

All safety related conditions, symbols and instructions

that appear in this operating manual or on the equipment
must be strictly followed to ensure operator and
instrument safety. Any misuse may impair the protection
provided by the equipment.

Read complete instructions prior to
installation and operation of the unit.

CAUTION :

SAFETY PRECAUTIONS

1. This equipment, being built-in-type, normally becomes

a part of the main control panel and the terminals do not
remain accessible to the user after installation.

2. Conductors must not come in contact with the internal

circuitry of the equipment else it may lead to a safety
hazard that may endanger life or cause electrical shock
to the operator.

3. Circuit breaker or mains switch must be installed

between the power source and supply terminals to
facilitate power 'ON' or ‘OFF' function.

4. The equipment shall not be installed in environmental

conditions other than those specified in this manual.

5. Since this equipment forms part of the main control

panel, its output terminals get connected to the host
equipment. Such equipment shall also comply to EMI /
EMC and safety requirements like CE standard
procedure.

6. Thermal dissipation of equipment is met through

ventilation holes provided on housing of equipment.
Obstruction of these ventilation holes may lead to a
safety hazard.

7. The output terminals shall be loaded strictly as per the

values / range specified by the manufacturer.

INSTALLATION INSTRUCTIONS

CAUTION

92

92

99

90.5

99

9

53

Side view

Front bezel

For installing the controller
1. Prepare the panel cutout with proper dimensions as

shown above.

2. Remove the clamp from the SMI.
3. Fix the unit into the cutout. Insert the clamp from both

sides and tighten the screws.

The equipment in its installed state must not come in

close proximity to any heating sources, caustic vapors,
oils, steam, or other unwanted process by products.

1. Use proper input power cables with shortest

connections and twisted type.

2. Layout of connecting cables shall be away from any

internal EMI source.

1. To avoid blockage of ventilation holes, clean the

equipment regularly using a soft cloth.

2. Do not use Isopropyl alcohol or any other organic

Solvents for cleaning.

EMC Guidelines :

MAINTENANCE

CAUTION

MECHANICAL INSTALLATION

Outline Dimensions

(in mm)

Panel Cutout

(in mm)

1. Wiring shall be done strictly according to the terminal

layout provided in the operating manual.

2. To eliminate electromagnetic interference use short

wire with adequate ratings and twists of equal size.

3. The power supply connection cable must have a cross

section of 1sq.mm or greater and insulation capacity of
at least 1.5KV.

WIRING INSTRUCTIONS

CAUTION

Internal

Reviews: