IMPORTANT SAFEGUARDS 

- READ ALL INSTRUCTIONS BEFORE USING – 

 

When using electrical products, especially when children are present, basic safety 
precautions should always be followed.  Warning to reduce the risk of burns, electrocution, 
fire or injury to persons: 

1.  Never put cigarette butts or other burning or hot objects in the toilet. 
2.  Use only attachments recommended by the manufacturer. 
3.  Close supervision is necessary when this product is being used by or near children or invalids. 
4.  Use this product only for its intended use as described in this manual. 
5.  Never block the air openings of the product or place it on a soft surface, such as a bed or couch, where the 

air openings may be blocked. Keep the air openings free of lint, hair, and the like. 

6.  Never drop or insert any objects into ventilation openings. 
7.  Unplug this product before cleaning. 
8.  Never operate this product if it has a damaged cord or plug, if it is not working properly, if it has been 

dropped or damaged, or if it has been dropped into water. Return the part to a service center for 
examination and repair. 

9.   Keep the cord away from heated surfaces. 
10.  Connect this product to a properly grounded outlet only. See Grounding Instructions below. 

 

- INSTALLATION INSTRUCTIONS - 

 

Key installation considerations include:  

1.  A suitable outlet for the venting pipe & urine waste pipe.  The preferred venting is through the wall, but 

it can also go through the roof or up through the attic & out the gable. 

2.  A suitable outlet for the urine waste.  These include in-ground options are existing septic system, grey 

water pit or class 3 gravel leach bed (cesspool).  Tank options include Ejektortank, pump-out tank or 
portable tank.  

3.  Contact local authorities to find out which building and environmental regulations apply in your region. 
4.  A 12V or 120V power supply is necessary for the Villa 9210. However, if no power is available, the 

vent pipe can be run above the roof line and a wind turbine vent can be added to create the draft 
required to vent the toilet.   

5.  Please be aware that the fans are sensitive to voltage spikes. If you are using a 12V system, an 

inverter from 12V to 120V is recommended and then using the adaptor reduces the chance of the 
voltage spiking the fan motor 

6.  A good quality voltage regulator is highly recommended if you are running 12V directly to the fan,  

 

Mounting the toilet: 

1.  Place the toilet where it is to be installed and determine desired mounting. 
2.  Measure and make holes for the urine waste pipe and venting pipe.  
3.  Install the rubber gasket on the bottom of the toilet. 
4.  Attach the toilet to the floor using three (3) screws through holes in the rotation disc, or to the wall 

using angle brackets or directly into a wall beam in lieu of the bracket. 

5.  If mounting to the floor, punch out the plugs in the screw holes with a screwdriver first. 
6.  If using the wall brackets, mark the location while the bracket is attached to the toilet, then remove the 

bracket from the inside of the toilet.  Mount the bracket to the wall and then mount the toilet to the 
bracket. 

 
Running the urine hose: 

1.  Run the flexible urine waste hose to the leach bed or tank.  The waste pipe must have an adequate 

drop through its entire length, so that the normal flow will prevent the build-up of salt deposits inside 
this drain.  

Summary of Contents for Villa 9210

Page 1: ...ns are existing septic system grey water pit or class 3 gravel leach bed cesspool Tank options include Ejektortank pump out tank or portable tank 3 Contact local authorities to find out which building and environmental regulations apply in your region 4 A 12V or 120V power supply is necessary for the Villa 9210 However if no power is available the vent pipe can be run above the roof line and a win...

Page 2: ... back wall venting application are included in the installation kit 2 If there is already a vent pipe from a previously installed toilet you may connect the Separett Villa to it 3 All joints in the venting pipe must be sealed with silicone or the equivalent 4 Only use venting pipes made of plastic 5 Applying soap will make it easier to join the ventilation and urine waste pipes to the toilet 6 The...

Page 3: ...e toilet is being used more frequently during a short period solid waste bags may prove necessary 4 Switch fan off only when container is empty removed or has its lid in place Otherwise it is easy for flies to enter and lay eggs 5 Regularly remove and clean the insect mesh on the fan intake The mesh keeps insects out of your bathroom and protects the fan from dust 6 Clean with non abrasive deterge...

Page 4: ...t as a trap 7 Using enzyme Bio Tabs will also help reduce the buildup of urine salts in the pipe and keep the toilet smelling fresh If the fan is noisy 1 Typically the fan is extremely quiet however if some sounds starts to emanate from the fan it likely has a buildup of dust on the fan blades 2 Unplug the power cable from the left side of the fan housing 3 Loosen the 2 black thumb screws at the b...

Page 5: ...olypropylene Seat is high gloss polypropylene Inner container and cover are polypropylene Weight 28 7 pounds 13 kg Venting pipe Ø ca 3 inches 75 mm Urine waste pipe Ø 1 25 inches 32 mm Electrical equipment Fan 12V 2 54W Electrical connection 3 foot 1 meter adaptor with 120V plug 3 foot 1 meter 12V power cable Power consumption 61watts 24 hrs ...