Remove the lamp unit.
• Loosen the securing screws from the lamp unit. Hold
the lamp unit by the handle and pull it in the direc-
tion of the arrow. At this time, keep the lamp unit
horizontal and do not tilt it.
Resetting the Lamp Timer
Reset the lamp timer after replacing the lamp.
Insert the new lamp unit.
• Press the lamp unit firmly into the lamp unit com-
partment. Fasten the securing screws.
Replace the lamp unit cover.
• Align the tab on the lamp unit cover (
1
)and place it
while pressing the tab (
2
) to close it. Then tighten
the user service screw (
3
) to secure the lamp unit
cover.
4
5
6
Connect the power cord.
• Plug the power cord into the AC socket of the pro-
jector.
Reset the lamp timer.
• While simultaneously holding down
U
MENU/HELP,
T
ENTER and
R
on the projector, press
S
STANDBY/ON on the projector.
• “LAMP 0000H” is displayed, indicating that the lamp
timer is reset.
• Make sure to reset the lamp timer only when replacing
the lamp. If you reset the lamp timer and continue to use
the same lamp, this may cause the lamp to become dam-
aged or explode.
1
2
Info
• If the lamp unit and lamp unit cover are not cor-
rectly installed, the power will not turn on, even if
the power cord is connected to the projector.
Info
Removing and Installing the Lamp Unit
• Make sure that you remove the lamp unit by the handle.
Do not touch the glass surface of the lamp unit or the
inside of the projector.
• To avoid injury to yourself and damage to the lamp,
make sure you carefully follow the steps below.
• Do not loosen other screws except for the lamp unit
cover and lamp unit.
Press
S
STANDBY/ON on the projector or
e
STANDBY on the remote control to put
the projector into standby mode.
• Wait until the cooling fan stops.
Disconnect the power cord.
• Unplug the power cord from the AC socket.
• Leave the lamp until it has fully cooled down (about
1 hour).
Info
1
2
IMPORTANT NOTE TO U.S. CUSTOMERS:
The lamp included with this projector is backed by a 90-day parts and labor limited warranty. All service of this
projector under warranty, including lamp replacement, must be obtained through a Sharp Authorized Projector
Dealer or Service Center*. For the name of the nearest Sharp Authorized Projector Dealer or Service Center*,
please call toll-free: 1-888-GO-SHARP (1-888-467-4277).
Hg LAMP CONTAINS MERCURY For State Lamp Disposal Information
www.lamprecycle.org or 1-800-BE-SHARP
■
It is recommended that the lamp (sold separately) be replaced when the remaining lamp life becomes 5% or less, or when you
notice a significant deterioration in the picture and color quality. The lamp life (percentage) can be checked with the on-screen
display.
CAUTION:
• Potential hazard of glass particles if lamp ruptures. Please have a Sharp Authorized Projector Dealer or Service
Center* replace lamp if rupture occurs.
• Do not remove the lamp unit directly after operation of the projector. The lamp may be extremely hot. Wait at least
one hour after the power cord is disconnected to allow the surface of the lamp unit to fully cool before removing
the lamp unit.
INSTALLATION MANUAL
LAMP UNIT (LAMP/CAGE MODULE) FOR PROJECTOR
Model
Remove the lamp unit cover.
• Turn the projector over. Loosen the user service
screw (
1
) that secures the lamp unit cover. Remove
the lamp unit cover (
2
).
3
U.S.A. ONLY
* Confirm the name of the Dealer or Service Center referring to your projector operation manual.
AN-XR20L2 / AN-XR10L2
Warning!
• Do not remove the lamp unit from the projector right after
use. The lamp and parts around the lamp will be very hot
and may cause burns or injury.
1
2
AC socket
User service screw
(for lamp unit cover)
STANDBY/ON button
AC socket
Securing screws
Handle
ENTER
button
MENU/HELP
button
R
button
2
1
3
STANDBY/ON
button
Printed in China
TINS-C742WJZZ
06P10-CH-NG
AN-XR20L2
06.9.12, 5:27 AM
2-3