background image

ENGLISH

FU-28H

AIR PURIFIER
INSTALLATION MANUAL

OPERATION MANUAL

LUFTREINIGER
INSTALLATIONSHANDBUCH

BEDIENUNGSANLEITUNG

PURIFICATEUR D’AIR
MANUEL D’INSTALLATION

MANUEL D’UTILISATION

PURIFICADOR DE AIRE
MANUAL DE INSTALACIÓN

MANUAL DE USO

PURIFICATORE DELL’ARIA
MANUALE D’INSTALLAZIONE

MANUALE OPERATIVO

LUCHTREINIGER
IINSTALLATIEHANDLEIDING

GEBRUIKSAANWIJZING

R

Wall-mounting type

Wandmontage

Type mural
De montaje en pared

Tipo da montare sul muro

Wandmodel

ENGLISH

DEUTSCH

FRANÇAIS

ESPAÑOL

ITALIANO

NEDERLANDS

*Plasmacluster is a trademark of

Sharp Corporation.

Summary of Contents for FU-28H

Page 1: ...N PURIFICADOR DE AIRE MANUAL DE INSTALACIÓN MANUAL DE USO PURIFICATORE DELL ARIA MANUALE D INSTALLAZIONE MANUALE OPERATIVO LUCHTREINIGER IINSTALLATIEHANDLEIDING GEBRUIKSAANWIJZING R Wall mounting type Wandmontage Type mural De montaje en pared Tipo da montare sul muro Wandmodel ENGLISH DEUTSCH FRANÇAIS ESPAÑOL ITALIANO NEDERLANDS Plasmacluster is a trademark of Sharp Corporation ...

Page 2: ......

Page 3: ...n air purifier draws in room air from its air intake lets the air pass through an Active Carbon Filter Deodorizing Filter and a HEPA Filter dust collec tion filter inside of the unit then discharges the air from its air outlet The air purifier unit repeats this process by moving its internal fan As air passes through the HEPA Filter can remove dust particles The Active Carbon Filter gradually abso...

Page 4: ...or similarly qualified person in order to avoid a hazard Do not operate when using aerosol insecticides or in rooms where there is oily residue incense sparks from lit cigarettes chemical fumes in the air or a humidity condition Use care when cleaning the air purifier Strong corrosive cleansers may damage the exterior Only Sharp Authorized Servicers should service this air purifier Contact the nea...

Page 5: ...stic temperature changes Place on a stable surface with sufficient air circulation Install the unit on a wall wooden pillar crosspiece etc that is flat and strong enough Do not install the unit on a thin wall or on plasterboard The unit may fall down if installed on an insufficiently strong wall To install the unit on a wooden wall that is less than 10 mm thick consult your dealer and have them co...

Page 6: ...dour Sensor Filter Frame HEPA Filter white with Microbial Control Filter blue Active Carbon Filter Deodorizing Filter Stainless Steel Pre Filter Front Panel BACK Power Cord Adjusting Guide Power Cord Power Plug ACCESSORIES Remote Control 1 unit Battery R6 AA battery X 2 Operation Manual Wall mounting kit Wall mounting bracket Wood screws 4 pcs Fisher plugs 4 pcs Air Outlet Shape of plug depends on...

Page 7: ...m battery fluid leakage The batteries of the accessory are for initial use only and may be depleted within 1 year INSERTING BATTERIES IN THE REMOTE CONTROL 1 Remove the back cover Press and slide the back cover to remove 2 Insert batteries Insert batteries with and as shown below 3 Close the back cover PREPARATION REMOTE CONTROL USE Operate the remote control facing the main unit receiver The sign...

Page 8: ...e is nothing that could obstruct installation of the unit Then fix the wall mounting bracket through screw holes with the supplied wood screws Install the unit on a wall wooden pillar crosspiece or the like that is flat and strong enough If the wall is weak or made of concrete have the unit installed by a specialist such as an electric appliance store Avoid locations near inverter lamps or where t...

Page 9: ...ugh Make sure that the unit is installed in an upright position without leaning to the right or left Wooden crosspiece Wall mounting bracket Hole on the wall Fisher plug Wood screw 2 Mount wall mounting bracket Mount the bracket using the included wood screws so that it is maintained level Installation on a concrete block or mortar surface Drill holes of at least 35 mm depth and 5 mm diameter into...

Page 10: ... of cloth until it is installed on the wall Do not lead the power cord together with other cord and do not twist it Never modify the power cord Take care not to damage the power cord Front Panel Filter Frame Air Outlet 1 2 3 Install the unit on the wall 1 Place the unit facing up remove the Front Panel and Filter Frame 2 Adjust the length of the power cord 1 Measure the distance between the unit a...

Page 11: ...es 5 Double check the installation Make sure that the claws of the unit are hooked in properly If they are not the unit will move sideways In addition the unit may fall off the wall and be damaged Make sure that the power cord is not caught in the unit 6 Remove the mark Wall mounting bracket HOW TO REMOVE THE UNIT Pull the power plug out of the wall outlet and remove the Front Panel and Filter Fra...

Page 12: ...ot operate properly 4 Place the Active Carbon Filter within the Filter Frame on top of the HEPA Filter The Active Carbon Filter does not have a front and a back 5 Next place the Pre Filter within the Filter Frame Fit the 4 tabs of the Pre Filter into the holes in the Filter Frame E 10 FILTER INSTALLATION Tabs Pre Filter Active Carbon Filter HEPA Filter Filter Frame HEPA Filter Filter Frame Pre Fil...

Page 13: ...tart date on the Date Label Use the date as a guide for the Filter Replacement schedule 8 Mount the Front Panel to the main unit 9 Insert the power plug into the wall outlet and check on off operation using the remote control Date Label Claw socket Claw Filter Frame Front Panel ...

Page 14: ...he set timer switches every time the button is pressed as shown below When 4 hours is selected 4 H indicator light activates When the remaining time becomes 1 hour then indicator light switches to 1 H E 12 For the first 30 seconds after the plug is inserted into the wall outlet the unit will check the conditions of the air Silent Max AUTO 1 hour 4 hours Cancel Auto Operation Odour sensor checks th...

Page 15: ...n the air MANUAL Fan Speed button The fan speed can be switched between Silent Max OFF Timer button The set timer switches every time the button is pressed as shown below When 4 hours is selected 4 H indicator light activates When the remaining time becomes 1 hour then indicator light switches to 1 H REMOTE CONTROL OPERATION Silent Max 1 hour 4 hours Cancel Plasmacluster Ion Operation While the pr...

Page 16: ...n power to half compared with that of new filters HEPA Filter About 12 months after opening Active Carbon Filter About 12 months after opening REPLACING THE FILTERS 1 See page E 10 11 for directions on how to install the filters when replacing 2 Fill in the usage start date of the filters on the Date Label Replacement Filters Model FZ 28SEF HEPA Filter 1 unit Active Carbon Filter 1 unit Please ask...

Page 17: ...old warm water Metal brushes or scrub brushes may cause damage After washing leave it in the shade until it gets dried Then place it back to the Filter Frame SPECIFICATIONS Model Power supply Fan speed Adjustment Rated Power Air Flow Volume Applicable Floor Surface Cord Length Dimensions Weight Fan speed Operation MAX 29 W 168m3 hour SILENT 3 1 W 30m3 hour The applicable floor surface area is the ...

Page 18: ... discharged air has an aroma or odour Check to see if the filters are heavily soiled Replace filters Refer to E 14 Plasmacluster Air Purifiers emit small traces of ozone which may produce an odour These ozone emissions are below safety levels set by the IEC 60335 2 65 Is the unit installed in a location that is difficult for the sensor to detect cigarette smoke Are the odour sensor openings blocke...

Page 19: ...ENGLISH ...

Page 20: ...SHARP CORPORATION TINS A119KKRZ 04BK 1 Printed in Japan ...